Cargando…

Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging

Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition. In this work, a fast imaging technique, termed variable flip angle...

Descripción completa

Detalles Bibliográficos
Autores principales: Dong, Zijing, Wang, Fuyixue, Chan, Kwok-Shing, Reese, Timothy G., Bilgic, Berkin, Marques, José P., Setsompop, Kawin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8221177/
https://www.ncbi.nlm.nih.gov/pubmed/33621694
http://dx.doi.org/10.1016/j.neuroimage.2021.117897
_version_ 1783711282702057472
author Dong, Zijing
Wang, Fuyixue
Chan, Kwok-Shing
Reese, Timothy G.
Bilgic, Berkin
Marques, José P.
Setsompop, Kawin
author_facet Dong, Zijing
Wang, Fuyixue
Chan, Kwok-Shing
Reese, Timothy G.
Bilgic, Berkin
Marques, José P.
Setsompop, Kawin
author_sort Dong, Zijing
collection PubMed
description Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition. In this work, a fast imaging technique, termed variable flip angle Echo Planar Time-Resolved Imaging (vFA-EPTI), is developed to acquire multi-echo and multi-flip-angle gradient-echo data with significantly reduced acquisition time, providing rich information for multi-compartment analysis of gradient-echo myelin water imaging (GRE-MWI). The proposed vFA-EPTI method achieved 26 folds acceleration with good accuracy by utilizing an efficient continuous readout, optimized spatiotemporal encoding across echoes and flip angles, as well as a joint subspace reconstruction. An approach to estimate off-resonance field changes between different flip-angle acquisitions was also developed to ensure high-quality joint reconstruction across flip angles. The accuracy of myelin water fraction (MWF) estimate under high acceleration was first validated by a retrospective undersampling experiment using a lengthy fully-sampled data as reference. Prospective experiments were then performed where whole-brain MWF and multi-compartment quantitative maps were obtained in 5 min at 1.5 mm isotropic resolution and 24 min at 1 mm isotropic resolution at 3T. Additionally, ultra-high resolution data at 600 μm isotropic resolution were acquired at 7T, which show detailed structures within the cortex such as the line of Gennari, demonstrating the ability of the proposed method for submillimeter GRE-MWI that can be used to study cortical myeloarchitecture in vivo.
format Online
Article
Text
id pubmed-8221177
institution National Center for Biotechnology Information
language English
publishDate 2021
record_format MEDLINE/PubMed
spelling pubmed-82211772021-06-23 Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging Dong, Zijing Wang, Fuyixue Chan, Kwok-Shing Reese, Timothy G. Bilgic, Berkin Marques, José P. Setsompop, Kawin Neuroimage Article Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition. In this work, a fast imaging technique, termed variable flip angle Echo Planar Time-Resolved Imaging (vFA-EPTI), is developed to acquire multi-echo and multi-flip-angle gradient-echo data with significantly reduced acquisition time, providing rich information for multi-compartment analysis of gradient-echo myelin water imaging (GRE-MWI). The proposed vFA-EPTI method achieved 26 folds acceleration with good accuracy by utilizing an efficient continuous readout, optimized spatiotemporal encoding across echoes and flip angles, as well as a joint subspace reconstruction. An approach to estimate off-resonance field changes between different flip-angle acquisitions was also developed to ensure high-quality joint reconstruction across flip angles. The accuracy of myelin water fraction (MWF) estimate under high acceleration was first validated by a retrospective undersampling experiment using a lengthy fully-sampled data as reference. Prospective experiments were then performed where whole-brain MWF and multi-compartment quantitative maps were obtained in 5 min at 1.5 mm isotropic resolution and 24 min at 1 mm isotropic resolution at 3T. Additionally, ultra-high resolution data at 600 μm isotropic resolution were acquired at 7T, which show detailed structures within the cortex such as the line of Gennari, demonstrating the ability of the proposed method for submillimeter GRE-MWI that can be used to study cortical myeloarchitecture in vivo. 2021-02-20 2021-05-15 /pmc/articles/PMC8221177/ /pubmed/33621694 http://dx.doi.org/10.1016/j.neuroimage.2021.117897 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Article
Dong, Zijing
Wang, Fuyixue
Chan, Kwok-Shing
Reese, Timothy G.
Bilgic, Berkin
Marques, José P.
Setsompop, Kawin
Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging
title Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging
title_full Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging
title_fullStr Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging
title_full_unstemmed Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging
title_short Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging
title_sort variable flip angle echo planar time-resolved imaging (vfa-epti) for fast high-resolution gradient echo myelin water imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8221177/
https://www.ncbi.nlm.nih.gov/pubmed/33621694
http://dx.doi.org/10.1016/j.neuroimage.2021.117897
work_keys_str_mv AT dongzijing variableflipangleechoplanartimeresolvedimagingvfaeptiforfasthighresolutiongradientechomyelinwaterimaging
AT wangfuyixue variableflipangleechoplanartimeresolvedimagingvfaeptiforfasthighresolutiongradientechomyelinwaterimaging
AT chankwokshing variableflipangleechoplanartimeresolvedimagingvfaeptiforfasthighresolutiongradientechomyelinwaterimaging
AT reesetimothyg variableflipangleechoplanartimeresolvedimagingvfaeptiforfasthighresolutiongradientechomyelinwaterimaging
AT bilgicberkin variableflipangleechoplanartimeresolvedimagingvfaeptiforfasthighresolutiongradientechomyelinwaterimaging
AT marquesjosep variableflipangleechoplanartimeresolvedimagingvfaeptiforfasthighresolutiongradientechomyelinwaterimaging
AT setsompopkawin variableflipangleechoplanartimeresolvedimagingvfaeptiforfasthighresolutiongradientechomyelinwaterimaging