Cargando…

Laryngotracheal aspiration test reduce the false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative nasopharyngeal swab

BACKGROUND: In the emergency department (ED) definitive diagnosis of SARS-COV-2 pneumonia is challenging as nasopharyngeal swab (NPS) can give false negative results. Strategies to reduce false negative rate of NPS have limitations. Serial NPSs (24–48 h from one another) are time-consuming, sputum c...

Descripción completa

Detalles Bibliográficos
Autores principales: Nazerian, Peiman, Sacco, Roberto M., Solbiati, Monica, Targetti, Elena, Marta, Chiara, Blasi, Francesco, Casazza, Giovanni, Colao, Maria Grazia, Tomassetti, Sara, Grifoni, Stefano, Rossolini, Gian Maria, Costantino, Giorgio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Federation of Internal Medicine. Published by Elsevier B.V. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8221977/
https://www.ncbi.nlm.nih.gov/pubmed/34210553
http://dx.doi.org/10.1016/j.ejim.2021.06.019
Descripción
Sumario:BACKGROUND: In the emergency department (ED) definitive diagnosis of SARS-COV-2 pneumonia is challenging as nasopharyngeal swab (NPS) can give false negative results. Strategies to reduce false negative rate of NPS have limitations. Serial NPSs (24–48 h from one another) are time-consuming, sputum can not be collected in the majority of patients, and bronchoalveolar lavage (BAL), the most sensitive test, requires specific expertise. Laryngotracheal aspiration (LTA) is easy to perform and showed a similar accuracy to BAL for diagnosis of other pulmonary diseases, however it was not studied to diagnose SARS-COV-2 pneumonia. OBJECTIVE: An observational cross-sectional study was performed to evaluate the negative predictive value of LTA in patients with suspected SARS-COV-2 pneumonia despite a negative NPS. METHODS: In the EDs of two university hospitals, consecutive patients with suspected SARS-COV-2 pneumonia despite a negative NPS underwent LTA performed with a nasotracheal tube connected to a vacuum system. Final diagnosis based on all respiratory specimen tests (NPS, LTA and BAL) and hospital data was established by two reviewers and in case of discordance by a third reviewer. RESULTS: 117 patients were enrolled. LTA was feasible in all patients and no patients experienced adverse events. Fifteen (12.7%) patients were diagnosed with community-acquired SARS-COV-2 pneumonia: 13 LTA positive and only 2 (1.7%) LTA negative. The negative predictive value of NPS and LTA was 87.3% (79.9% – 92.7%) and 98.1% (93.3%99.8%) respectively. CONCLUSIONS: LTA resulted feasible, safe and reduced false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative NPS.