Cargando…

CT-scan based anatomical study as a guidance for infra-acetabular screw placement

BACKGROUND: The infra-acetabular corridor is quite narrow, which makes a challenge for the orthopedists to insert the screw. This study aimed to explore the relationship between the infra-acetabular corridor diameter (IACD) and the minimum thickness of medial acetabular wall (MTMAW), and to clarify...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Quanyi, Zhou, Runtao, Gao, Shichang, Liang, Anlin, Yang, Mingming, Yang, Haitao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8223348/
https://www.ncbi.nlm.nih.gov/pubmed/34167496
http://dx.doi.org/10.1186/s12891-021-04419-x
_version_ 1783711674139672576
author Lu, Quanyi
Zhou, Runtao
Gao, Shichang
Liang, Anlin
Yang, Mingming
Yang, Haitao
author_facet Lu, Quanyi
Zhou, Runtao
Gao, Shichang
Liang, Anlin
Yang, Mingming
Yang, Haitao
author_sort Lu, Quanyi
collection PubMed
description BACKGROUND: The infra-acetabular corridor is quite narrow, which makes a challenge for the orthopedists to insert the screw. This study aimed to explore the relationship between the infra-acetabular corridor diameter (IACD) and the minimum thickness of medial acetabular wall (MTMAW), and to clarify the way of screw placement. METHODS: The Computed tomography (CT) data of 100 normal adult pelvises (50 males and 50 females respectively) were collected and pelvis three-dimensional (3D) reconstruction was performed by using Mimics software and the 3D model was imported into Geomagic Studio software. The perspective of acetabulum was carried out orienting from iliopubic eminence to ischial tuberosity and the IACD was measured by placing virtual screws which was vertical to the corridor transverse section of “teardrop”. The relationship between IACD and MTMAW was analyzed. When IACD was ≥5 mm, 3.5 mm all-in screws were placed. When IACD was < 5 mm, 3.5 mm in-out-in screws were placed. RESULTS: The IACD of males and females were (6.15 ± 1.24) mm and (5.42 ± 1.01) mm and the MTMAW in males and females were (4.40 ± 1.23) mm and (3.60 ± 0.81) mm respectively. The IACD and MTMAW in males were significantly wider than those of females (P < 0.05), and IACD was positively correlated with MTMAW (r = 0.859), the regression equation was IACD = 2.111 + 0.917 MTMAW. In the all-in screw group, 38 cases (76%) were males and 33 cases (66%) were females respectively. The entry point was located at posteromedial of the apex of iliopubic eminence, and the posterior distance and medial distance were (8.03 ± 2.01) mm and (8.49 ± 2.68) mm respectively in males. As for females, those were (8.68 ± 2.35) mm and (8.87 ± 2.79) mm respectively. In the in-out-in screw group, 12 cases (24%) were males and 17 cases (34%) were females, respectively. The posterior distance and medial distance between the entry point and the apex of iliopubic eminence were (10.49 ± 2.58) mm and (6.17 ± 1.84) mm respectively in males. As for females, those were (10.10 ± 2.63) mm and (6.63 ± 1.49) mm respectively. The angle between the infra-acetabular screw and the sagittal plane was medial inclination (0.42 ± 6.49) °in males, lateral inclination (8.09 ± 6.33) °in females, and the angle between the infra-acetabular screw and the coronal plane was posterior inclination (54.06 ± 7.37) °. CONCLUSIONS: The placement mode of the infra-acetabular screw (IAS) can be determined preoperatively by measuring the MTMAW in the CT axial layers. Compared with all-in screw, the in-out-in screw entry point was around 2 mm outwards and backwards, and closer to true pelvic rim.
format Online
Article
Text
id pubmed-8223348
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-82233482021-06-24 CT-scan based anatomical study as a guidance for infra-acetabular screw placement Lu, Quanyi Zhou, Runtao Gao, Shichang Liang, Anlin Yang, Mingming Yang, Haitao BMC Musculoskelet Disord Research BACKGROUND: The infra-acetabular corridor is quite narrow, which makes a challenge for the orthopedists to insert the screw. This study aimed to explore the relationship between the infra-acetabular corridor diameter (IACD) and the minimum thickness of medial acetabular wall (MTMAW), and to clarify the way of screw placement. METHODS: The Computed tomography (CT) data of 100 normal adult pelvises (50 males and 50 females respectively) were collected and pelvis three-dimensional (3D) reconstruction was performed by using Mimics software and the 3D model was imported into Geomagic Studio software. The perspective of acetabulum was carried out orienting from iliopubic eminence to ischial tuberosity and the IACD was measured by placing virtual screws which was vertical to the corridor transverse section of “teardrop”. The relationship between IACD and MTMAW was analyzed. When IACD was ≥5 mm, 3.5 mm all-in screws were placed. When IACD was < 5 mm, 3.5 mm in-out-in screws were placed. RESULTS: The IACD of males and females were (6.15 ± 1.24) mm and (5.42 ± 1.01) mm and the MTMAW in males and females were (4.40 ± 1.23) mm and (3.60 ± 0.81) mm respectively. The IACD and MTMAW in males were significantly wider than those of females (P < 0.05), and IACD was positively correlated with MTMAW (r = 0.859), the regression equation was IACD = 2.111 + 0.917 MTMAW. In the all-in screw group, 38 cases (76%) were males and 33 cases (66%) were females respectively. The entry point was located at posteromedial of the apex of iliopubic eminence, and the posterior distance and medial distance were (8.03 ± 2.01) mm and (8.49 ± 2.68) mm respectively in males. As for females, those were (8.68 ± 2.35) mm and (8.87 ± 2.79) mm respectively. In the in-out-in screw group, 12 cases (24%) were males and 17 cases (34%) were females, respectively. The posterior distance and medial distance between the entry point and the apex of iliopubic eminence were (10.49 ± 2.58) mm and (6.17 ± 1.84) mm respectively in males. As for females, those were (10.10 ± 2.63) mm and (6.63 ± 1.49) mm respectively. The angle between the infra-acetabular screw and the sagittal plane was medial inclination (0.42 ± 6.49) °in males, lateral inclination (8.09 ± 6.33) °in females, and the angle between the infra-acetabular screw and the coronal plane was posterior inclination (54.06 ± 7.37) °. CONCLUSIONS: The placement mode of the infra-acetabular screw (IAS) can be determined preoperatively by measuring the MTMAW in the CT axial layers. Compared with all-in screw, the in-out-in screw entry point was around 2 mm outwards and backwards, and closer to true pelvic rim. BioMed Central 2021-06-24 /pmc/articles/PMC8223348/ /pubmed/34167496 http://dx.doi.org/10.1186/s12891-021-04419-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Lu, Quanyi
Zhou, Runtao
Gao, Shichang
Liang, Anlin
Yang, Mingming
Yang, Haitao
CT-scan based anatomical study as a guidance for infra-acetabular screw placement
title CT-scan based anatomical study as a guidance for infra-acetabular screw placement
title_full CT-scan based anatomical study as a guidance for infra-acetabular screw placement
title_fullStr CT-scan based anatomical study as a guidance for infra-acetabular screw placement
title_full_unstemmed CT-scan based anatomical study as a guidance for infra-acetabular screw placement
title_short CT-scan based anatomical study as a guidance for infra-acetabular screw placement
title_sort ct-scan based anatomical study as a guidance for infra-acetabular screw placement
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8223348/
https://www.ncbi.nlm.nih.gov/pubmed/34167496
http://dx.doi.org/10.1186/s12891-021-04419-x
work_keys_str_mv AT luquanyi ctscanbasedanatomicalstudyasaguidanceforinfraacetabularscrewplacement
AT zhouruntao ctscanbasedanatomicalstudyasaguidanceforinfraacetabularscrewplacement
AT gaoshichang ctscanbasedanatomicalstudyasaguidanceforinfraacetabularscrewplacement
AT lianganlin ctscanbasedanatomicalstudyasaguidanceforinfraacetabularscrewplacement
AT yangmingming ctscanbasedanatomicalstudyasaguidanceforinfraacetabularscrewplacement
AT yanghaitao ctscanbasedanatomicalstudyasaguidanceforinfraacetabularscrewplacement