Assessment of the Adaptive Force of Elbow Extensors in Healthy Subjects Quantified by a Novel Pneumatically Driven Measurement System with Considerations of Its Quality Criteria

Adaptive Force (AF) reflects the capability of the neuromuscular system to adapt adequately to external forces with the intention of maintaining a position or motion. One specific approach to assessing AF is to measure force and limb position during a pneumatically applied increasing external force....

Descripción completa

Detalles Bibliográficos
Autores principales: Dech, Silas, Bittmann, Frank N., Schaefer, Laura V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8224031/
https://www.ncbi.nlm.nih.gov/pubmed/34063869
http://dx.doi.org/10.3390/diagnostics11060923
_version_ 1783711808501055488
author Dech, Silas
Bittmann, Frank N.
Schaefer, Laura V.
author_facet Dech, Silas
Bittmann, Frank N.
Schaefer, Laura V.
author_sort Dech, Silas
collection PubMed
description Adaptive Force (AF) reflects the capability of the neuromuscular system to adapt adequately to external forces with the intention of maintaining a position or motion. One specific approach to assessing AF is to measure force and limb position during a pneumatically applied increasing external force. Through this method, the highest (AF(max)), the maximal isometric (AFiso(max)) and the maximal eccentric Adaptive Force (AFecc(max)) can be determined. The main question of the study was whether the AFiso(max) is a specific and independent parameter of muscle function compared to other maximal forces. In 13 healthy subjects (9 male and 4 female), the maximal voluntary isometric contraction (pre- and post-MVIC), the three AF parameters and the MVIC with a prior concentric contraction (MVICpri-con) of the elbow extensors were measured 4 times on two days. Arithmetic mean (M) and maximal (Max) torques of all force types were analyzed. Regarding the reliability of the AF parameters between days, the mean changes were 0.31–1.98 Nm (0.61%–5.47%, p = 0.175–0.552), the standard errors of measurements (SEM) were 1.29–5.68 Nm (2.53%–15.70%) and the ICCs(3,1) = 0.896–0.996. M and Max of AFiso(max), AF(max) and pre-MVIC correlated highly (r = 0.85–0.98). The M and Max of AFiso(max) were significantly lower (6.12–14.93 Nm; p ≤ 0.001–0.009) and more variable between trials (coefficient of variation (CVs) ≥ 21.95%) compared to those of pre-MVIC and AF(max) (CVs ≤ 5.4%). The results suggest the novel measuring procedure is suitable to reliably quantify the AF, whereby the presented measurement errors should be taken into consideration. The AFiso(max) seems to reflect its own strength capacity and should be detected separately. It is suggested its normalization to the MVIC or AF(max) could serve as an indicator of a neuromuscular function.
format Online
Article
Text
id pubmed-8224031
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82240312021-06-25 Assessment of the Adaptive Force of Elbow Extensors in Healthy Subjects Quantified by a Novel Pneumatically Driven Measurement System with Considerations of Its Quality Criteria Dech, Silas Bittmann, Frank N. Schaefer, Laura V. Diagnostics (Basel) Article Adaptive Force (AF) reflects the capability of the neuromuscular system to adapt adequately to external forces with the intention of maintaining a position or motion. One specific approach to assessing AF is to measure force and limb position during a pneumatically applied increasing external force. Through this method, the highest (AF(max)), the maximal isometric (AFiso(max)) and the maximal eccentric Adaptive Force (AFecc(max)) can be determined. The main question of the study was whether the AFiso(max) is a specific and independent parameter of muscle function compared to other maximal forces. In 13 healthy subjects (9 male and 4 female), the maximal voluntary isometric contraction (pre- and post-MVIC), the three AF parameters and the MVIC with a prior concentric contraction (MVICpri-con) of the elbow extensors were measured 4 times on two days. Arithmetic mean (M) and maximal (Max) torques of all force types were analyzed. Regarding the reliability of the AF parameters between days, the mean changes were 0.31–1.98 Nm (0.61%–5.47%, p = 0.175–0.552), the standard errors of measurements (SEM) were 1.29–5.68 Nm (2.53%–15.70%) and the ICCs(3,1) = 0.896–0.996. M and Max of AFiso(max), AF(max) and pre-MVIC correlated highly (r = 0.85–0.98). The M and Max of AFiso(max) were significantly lower (6.12–14.93 Nm; p ≤ 0.001–0.009) and more variable between trials (coefficient of variation (CVs) ≥ 21.95%) compared to those of pre-MVIC and AF(max) (CVs ≤ 5.4%). The results suggest the novel measuring procedure is suitable to reliably quantify the AF, whereby the presented measurement errors should be taken into consideration. The AFiso(max) seems to reflect its own strength capacity and should be detected separately. It is suggested its normalization to the MVIC or AF(max) could serve as an indicator of a neuromuscular function. MDPI 2021-05-21 /pmc/articles/PMC8224031/ /pubmed/34063869 http://dx.doi.org/10.3390/diagnostics11060923 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dech, Silas
Bittmann, Frank N.
Schaefer, Laura V.
Assessment of the Adaptive Force of Elbow Extensors in Healthy Subjects Quantified by a Novel Pneumatically Driven Measurement System with Considerations of Its Quality Criteria
title Assessment of the Adaptive Force of Elbow Extensors in Healthy Subjects Quantified by a Novel Pneumatically Driven Measurement System with Considerations of Its Quality Criteria
title_full Assessment of the Adaptive Force of Elbow Extensors in Healthy Subjects Quantified by a Novel Pneumatically Driven Measurement System with Considerations of Its Quality Criteria
title_fullStr Assessment of the Adaptive Force of Elbow Extensors in Healthy Subjects Quantified by a Novel Pneumatically Driven Measurement System with Considerations of Its Quality Criteria
title_full_unstemmed Assessment of the Adaptive Force of Elbow Extensors in Healthy Subjects Quantified by a Novel Pneumatically Driven Measurement System with Considerations of Its Quality Criteria
title_short Assessment of the Adaptive Force of Elbow Extensors in Healthy Subjects Quantified by a Novel Pneumatically Driven Measurement System with Considerations of Its Quality Criteria
title_sort assessment of the adaptive force of elbow extensors in healthy subjects quantified by a novel pneumatically driven measurement system with considerations of its quality criteria
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8224031/
https://www.ncbi.nlm.nih.gov/pubmed/34063869
http://dx.doi.org/10.3390/diagnostics11060923
work_keys_str_mv AT dechsilas assessmentoftheadaptiveforceofelbowextensorsinhealthysubjectsquantifiedbyanovelpneumaticallydrivenmeasurementsystemwithconsiderationsofitsqualitycriteria
AT bittmannfrankn assessmentoftheadaptiveforceofelbowextensorsinhealthysubjectsquantifiedbyanovelpneumaticallydrivenmeasurementsystemwithconsiderationsofitsqualitycriteria
AT schaeferlaurav assessmentoftheadaptiveforceofelbowextensorsinhealthysubjectsquantifiedbyanovelpneumaticallydrivenmeasurementsystemwithconsiderationsofitsqualitycriteria