Cargando…

Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy

Objective: We compare the repeatability and accuracy of ultrasound shear wave elastography (USE) and transient optical coherence elastography (OCE). Methods: Elastic wave speed in gelatin phantoms and chicken breast was measured with USE and OCE and compared with uniaxial mechanical compression test...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8224461/
https://www.ncbi.nlm.nih.gov/pubmed/34179823
http://dx.doi.org/10.1109/OJEMB.2021.3075569
_version_ 1783711894372089856
collection PubMed
description Objective: We compare the repeatability and accuracy of ultrasound shear wave elastography (USE) and transient optical coherence elastography (OCE). Methods: Elastic wave speed in gelatin phantoms and chicken breast was measured with USE and OCE and compared with uniaxial mechanical compression testing. Intra- and Inter-repeatability were analyzed using Bland-Altman plots and intraclass correlation coefficients (ICC). Results: OCE and USE differed from uniaxial testing by a mean absolute percent error of 8.92% and 16.9%, respectively, across eight phantoms of varying stiffness. Upper and lower limits of agreement for intrasample repeatability for USE and OCE were ±0.075 m/s and −0.14 m/s and 0.13 m/s, respectively. OCE and USE both had ICCs of 0.9991. In chicken breast, ICC for USE was 0.9385 and for OCE was 0.9924. Conclusion: OCE and USE can detect small speed changes and give comparable measurements. These measurements correspond well with uniaxial testing.
format Online
Article
Text
id pubmed-8224461
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-82244612021-06-24 Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy IEEE Open J Eng Med Biol Article Objective: We compare the repeatability and accuracy of ultrasound shear wave elastography (USE) and transient optical coherence elastography (OCE). Methods: Elastic wave speed in gelatin phantoms and chicken breast was measured with USE and OCE and compared with uniaxial mechanical compression testing. Intra- and Inter-repeatability were analyzed using Bland-Altman plots and intraclass correlation coefficients (ICC). Results: OCE and USE differed from uniaxial testing by a mean absolute percent error of 8.92% and 16.9%, respectively, across eight phantoms of varying stiffness. Upper and lower limits of agreement for intrasample repeatability for USE and OCE were ±0.075 m/s and −0.14 m/s and 0.13 m/s, respectively. OCE and USE both had ICCs of 0.9991. In chicken breast, ICC for USE was 0.9385 and for OCE was 0.9924. Conclusion: OCE and USE can detect small speed changes and give comparable measurements. These measurements correspond well with uniaxial testing. IEEE 2021-04-27 /pmc/articles/PMC8224461/ /pubmed/34179823 http://dx.doi.org/10.1109/OJEMB.2021.3075569 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy
title Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy
title_full Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy
title_fullStr Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy
title_full_unstemmed Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy
title_short Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy
title_sort ultrasound shear wave elastography and transient optical coherence elastography: side-by-side comparison of repeatability and accuracy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8224461/
https://www.ncbi.nlm.nih.gov/pubmed/34179823
http://dx.doi.org/10.1109/OJEMB.2021.3075569
work_keys_str_mv AT ultrasoundshearwaveelastographyandtransientopticalcoherenceelastographysidebysidecomparisonofrepeatabilityandaccuracy
AT ultrasoundshearwaveelastographyandtransientopticalcoherenceelastographysidebysidecomparisonofrepeatabilityandaccuracy
AT ultrasoundshearwaveelastographyandtransientopticalcoherenceelastographysidebysidecomparisonofrepeatabilityandaccuracy
AT ultrasoundshearwaveelastographyandtransientopticalcoherenceelastographysidebysidecomparisonofrepeatabilityandaccuracy