Initial Experience with a Novel Pericardiocentesis Training Simulator Incorporating a Three-dimensional Printed Cardiac Model

Pericardial effusion is a rare but serious complication in cardiac electrophysiology procedures. To avoid progression to acute tamponade and reduce the risk of adverse patient outcomes, emergent pericardiocentesis is often necessary. The conduct of more pericardiocentesis training may further mitiga...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsai, Sam L., Seslar, Stephen P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8225301/
https://www.ncbi.nlm.nih.gov/pubmed/34234989
http://dx.doi.org/10.19102/icrm.2021.120603
_version_ 1783712062303633408
author Tsai, Sam L.
Seslar, Stephen P.
author_facet Tsai, Sam L.
Seslar, Stephen P.
author_sort Tsai, Sam L.
collection PubMed
description Pericardial effusion is a rare but serious complication in cardiac electrophysiology procedures. To avoid progression to acute tamponade and reduce the risk of adverse patient outcomes, emergent pericardiocentesis is often necessary. The conduct of more pericardiocentesis training may further mitigate this risk. However, teaching and practice opportunities are rare, creating the need for pericardiocentesis simulators. While various pericardiocentesis simulators exist, their applications have been limited; further, commercial simulators are anatomically realistic but can be expensive. As such, cheaper homemade simulators have been developed, yet these may lack the cardiac anatomical features for a high-fidelity simulation or may be overly complex to assemble. The purpose of this study is to report initial findings from a pericardiocentesis simulator that incorporates a three-dimensional (3D) cardiac model that is economical, simple to assemble, and anatomically accurate. A 3D-printed cardiac model was printed from a computed tomography file. The model was fitted with a latex balloon-in-a-balloon pericardium filled with colored saline and placed in an ultrasound-compatible gelatin mold to create a pericardiocentesis simulator. The simulator was then tested with experienced and novice trainees at an academic hospital. A total of 10 participants (four interventional cardiology faculty members and six cardiology fellows) performed simulated pericardiocentesis using the simulator and completed a questionnaire to evaluate the model’s features and usefulness. The overall feedback regarding this novel simulation approach was positive and the model exhibited important anatomical features to accurately simulate ultrasound-guided pericardiocentesis. All participants were able to successfully insert the needle into the pericardial space and all but one successfully placed the pericardial drain. Survey results indicated that the model was largely perceived as useful for training. This work suggests incorporating a 3D-printed cardiac model into a gelatin mold results in a simple and inexpensive yet high-fidelity pericardiocentesis simulation experience. This novel approach may be useful for teaching pericardiocentesis in an academic hospital.
format Online
Article
Text
id pubmed-8225301
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MediaSphere Medical
record_format MEDLINE/PubMed
spelling pubmed-82253012021-07-06 Initial Experience with a Novel Pericardiocentesis Training Simulator Incorporating a Three-dimensional Printed Cardiac Model Tsai, Sam L. Seslar, Stephen P. J Innov Card Rhythm Manag Original Research Pericardial effusion is a rare but serious complication in cardiac electrophysiology procedures. To avoid progression to acute tamponade and reduce the risk of adverse patient outcomes, emergent pericardiocentesis is often necessary. The conduct of more pericardiocentesis training may further mitigate this risk. However, teaching and practice opportunities are rare, creating the need for pericardiocentesis simulators. While various pericardiocentesis simulators exist, their applications have been limited; further, commercial simulators are anatomically realistic but can be expensive. As such, cheaper homemade simulators have been developed, yet these may lack the cardiac anatomical features for a high-fidelity simulation or may be overly complex to assemble. The purpose of this study is to report initial findings from a pericardiocentesis simulator that incorporates a three-dimensional (3D) cardiac model that is economical, simple to assemble, and anatomically accurate. A 3D-printed cardiac model was printed from a computed tomography file. The model was fitted with a latex balloon-in-a-balloon pericardium filled with colored saline and placed in an ultrasound-compatible gelatin mold to create a pericardiocentesis simulator. The simulator was then tested with experienced and novice trainees at an academic hospital. A total of 10 participants (four interventional cardiology faculty members and six cardiology fellows) performed simulated pericardiocentesis using the simulator and completed a questionnaire to evaluate the model’s features and usefulness. The overall feedback regarding this novel simulation approach was positive and the model exhibited important anatomical features to accurately simulate ultrasound-guided pericardiocentesis. All participants were able to successfully insert the needle into the pericardial space and all but one successfully placed the pericardial drain. Survey results indicated that the model was largely perceived as useful for training. This work suggests incorporating a 3D-printed cardiac model into a gelatin mold results in a simple and inexpensive yet high-fidelity pericardiocentesis simulation experience. This novel approach may be useful for teaching pericardiocentesis in an academic hospital. MediaSphere Medical 2021-06-15 /pmc/articles/PMC8225301/ /pubmed/34234989 http://dx.doi.org/10.19102/icrm.2021.120603 Text en Copyright: © 2021 Innovations in Cardiac Rhythm Management https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Tsai, Sam L.
Seslar, Stephen P.
Initial Experience with a Novel Pericardiocentesis Training Simulator Incorporating a Three-dimensional Printed Cardiac Model
title Initial Experience with a Novel Pericardiocentesis Training Simulator Incorporating a Three-dimensional Printed Cardiac Model
title_full Initial Experience with a Novel Pericardiocentesis Training Simulator Incorporating a Three-dimensional Printed Cardiac Model
title_fullStr Initial Experience with a Novel Pericardiocentesis Training Simulator Incorporating a Three-dimensional Printed Cardiac Model
title_full_unstemmed Initial Experience with a Novel Pericardiocentesis Training Simulator Incorporating a Three-dimensional Printed Cardiac Model
title_short Initial Experience with a Novel Pericardiocentesis Training Simulator Incorporating a Three-dimensional Printed Cardiac Model
title_sort initial experience with a novel pericardiocentesis training simulator incorporating a three-dimensional printed cardiac model
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8225301/
https://www.ncbi.nlm.nih.gov/pubmed/34234989
http://dx.doi.org/10.19102/icrm.2021.120603
work_keys_str_mv AT tsaisaml initialexperiencewithanovelpericardiocentesistrainingsimulatorincorporatingathreedimensionalprintedcardiacmodel
AT seslarstephenp initialexperiencewithanovelpericardiocentesistrainingsimulatorincorporatingathreedimensionalprintedcardiacmodel