Cargando…

Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination

Extracorporeal carbon dioxide removal (ECCO(2)R) is an important technique to treat critical lung diseases such as exacerbated chronic obstructive pulmonary disease (COPD) and mild or moderate acute respiratory distress syndrome (ARDS). This study applies our previously presented ECCO(2)R mock circu...

Descripción completa

Detalles Bibliográficos
Autores principales: Schwärzel, Leonie S., Jungmann, Anna M., Schmoll, Nicole, Caspari, Stefan, Seiler, Frederik, Muellenbach, Ralf M., Bewarder, Moritz, Dinh, Quoc Thai, Bals, Robert, Lepper, Philipp M., Omlor, Albert J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8227238/
https://www.ncbi.nlm.nih.gov/pubmed/34072067
http://dx.doi.org/10.3390/membranes11060398
_version_ 1783712478150000640
author Schwärzel, Leonie S.
Jungmann, Anna M.
Schmoll, Nicole
Caspari, Stefan
Seiler, Frederik
Muellenbach, Ralf M.
Bewarder, Moritz
Dinh, Quoc Thai
Bals, Robert
Lepper, Philipp M.
Omlor, Albert J.
author_facet Schwärzel, Leonie S.
Jungmann, Anna M.
Schmoll, Nicole
Caspari, Stefan
Seiler, Frederik
Muellenbach, Ralf M.
Bewarder, Moritz
Dinh, Quoc Thai
Bals, Robert
Lepper, Philipp M.
Omlor, Albert J.
author_sort Schwärzel, Leonie S.
collection PubMed
description Extracorporeal carbon dioxide removal (ECCO(2)R) is an important technique to treat critical lung diseases such as exacerbated chronic obstructive pulmonary disease (COPD) and mild or moderate acute respiratory distress syndrome (ARDS). This study applies our previously presented ECCO(2)R mock circuit to compare the CO(2) removal capacity of circular versus parallel-plated membrane lungs at different sweep gas flow rates (0.5, 2, 4, 6 L/min) and blood flow rates (0.3 L/min, 0.9 L/min). For both designs, two low-flow polypropylene membrane lungs (Medos Hilte 1000, Quadrox-i Neonatal) and two mid-flow polymethylpentene membrane lungs (Novalung Minilung, Quadrox-iD Pediatric) were compared. While the parallel-plated Quadrox-iD Pediatric achieved the overall highest CO(2) removal rates under medium and high sweep gas flow rates, the two circular membrane lungs performed relatively better at the lowest gas flow rate of 0.5 L/min. The low-flow Hilite 1000, although overall better than the Quadrox i-Neonatal, had the most significant advantage at a gas flow of 0.5 L/min. Moreover, the circular Minilung, despite being significantly less efficient than the Quadrox-iD Pediatric at medium and high sweep gas flow rates, did not show a significantly worse CO(2) removal rate at a gas flow of 0.5 L/min but rather a slight advantage. We suggest that circular membrane lungs have an advantage at low sweep gas flow rates due to reduced shunting as a result of their fiber orientation. Efficiency for such low gas flow scenarios might be relevant for possible future portable ECCO(2)R devices.
format Online
Article
Text
id pubmed-8227238
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82272382021-06-26 Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination Schwärzel, Leonie S. Jungmann, Anna M. Schmoll, Nicole Caspari, Stefan Seiler, Frederik Muellenbach, Ralf M. Bewarder, Moritz Dinh, Quoc Thai Bals, Robert Lepper, Philipp M. Omlor, Albert J. Membranes (Basel) Article Extracorporeal carbon dioxide removal (ECCO(2)R) is an important technique to treat critical lung diseases such as exacerbated chronic obstructive pulmonary disease (COPD) and mild or moderate acute respiratory distress syndrome (ARDS). This study applies our previously presented ECCO(2)R mock circuit to compare the CO(2) removal capacity of circular versus parallel-plated membrane lungs at different sweep gas flow rates (0.5, 2, 4, 6 L/min) and blood flow rates (0.3 L/min, 0.9 L/min). For both designs, two low-flow polypropylene membrane lungs (Medos Hilte 1000, Quadrox-i Neonatal) and two mid-flow polymethylpentene membrane lungs (Novalung Minilung, Quadrox-iD Pediatric) were compared. While the parallel-plated Quadrox-iD Pediatric achieved the overall highest CO(2) removal rates under medium and high sweep gas flow rates, the two circular membrane lungs performed relatively better at the lowest gas flow rate of 0.5 L/min. The low-flow Hilite 1000, although overall better than the Quadrox i-Neonatal, had the most significant advantage at a gas flow of 0.5 L/min. Moreover, the circular Minilung, despite being significantly less efficient than the Quadrox-iD Pediatric at medium and high sweep gas flow rates, did not show a significantly worse CO(2) removal rate at a gas flow of 0.5 L/min but rather a slight advantage. We suggest that circular membrane lungs have an advantage at low sweep gas flow rates due to reduced shunting as a result of their fiber orientation. Efficiency for such low gas flow scenarios might be relevant for possible future portable ECCO(2)R devices. MDPI 2021-05-27 /pmc/articles/PMC8227238/ /pubmed/34072067 http://dx.doi.org/10.3390/membranes11060398 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Schwärzel, Leonie S.
Jungmann, Anna M.
Schmoll, Nicole
Caspari, Stefan
Seiler, Frederik
Muellenbach, Ralf M.
Bewarder, Moritz
Dinh, Quoc Thai
Bals, Robert
Lepper, Philipp M.
Omlor, Albert J.
Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination
title Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination
title_full Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination
title_fullStr Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination
title_full_unstemmed Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination
title_short Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination
title_sort comparison of circular and parallel-plated membrane lungs for extracorporeal carbon dioxide elimination
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8227238/
https://www.ncbi.nlm.nih.gov/pubmed/34072067
http://dx.doi.org/10.3390/membranes11060398
work_keys_str_mv AT schwarzelleonies comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT jungmannannam comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT schmollnicole comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT casparistefan comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT seilerfrederik comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT muellenbachralfm comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT bewardermoritz comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT dinhquocthai comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT balsrobert comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT lepperphilippm comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination
AT omloralbertj comparisonofcircularandparallelplatedmembranelungsforextracorporealcarbondioxideelimination