Cargando…

Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT

The aim of this study is to assess whether perifocal bone marrow edema (BME) in patients with osteoid osteoma (OO) can be accurately detected on dual-layer spectral CT (DLCT) with three-material decomposition. To that end, 18 patients with OO (25.33 ± 12.44 years; 7 females) were pairwise-matched wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Gassert, Florian T., Hammel, Johannes, Hofmann, Felix C., Neumann, Jan, von Schacky, Claudio E., Gassert, Felix G., Pfeiffer, Daniela, Pfeiffer, Franz, Makowski, Marcus R., Woertler, Klaus, Gersing, Alexandra S., Schwaiger, Benedikt J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8227561/
https://www.ncbi.nlm.nih.gov/pubmed/34073416
http://dx.doi.org/10.3390/diagnostics11060953
_version_ 1783712551712849920
author Gassert, Florian T.
Hammel, Johannes
Hofmann, Felix C.
Neumann, Jan
von Schacky, Claudio E.
Gassert, Felix G.
Pfeiffer, Daniela
Pfeiffer, Franz
Makowski, Marcus R.
Woertler, Klaus
Gersing, Alexandra S.
Schwaiger, Benedikt J.
author_facet Gassert, Florian T.
Hammel, Johannes
Hofmann, Felix C.
Neumann, Jan
von Schacky, Claudio E.
Gassert, Felix G.
Pfeiffer, Daniela
Pfeiffer, Franz
Makowski, Marcus R.
Woertler, Klaus
Gersing, Alexandra S.
Schwaiger, Benedikt J.
author_sort Gassert, Florian T.
collection PubMed
description The aim of this study is to assess whether perifocal bone marrow edema (BME) in patients with osteoid osteoma (OO) can be accurately detected on dual-layer spectral CT (DLCT) with three-material decomposition. To that end, 18 patients with OO (25.33 ± 12.44 years; 7 females) were pairwise-matched with 18 patients (26.72 ± 9.65 years; 9 females) admitted for suspected pathologies other than OO in the same anatomic location but negative imaging findings. All patients were examined with DLCT and MRI. DLCT data was decomposed into hydroxyapatite and water- and fat-equivalent volume fraction maps. Two radiologists assessed DLCT-based volume fraction maps for the presence of perifocal BME, using a Likert scale (1 = no edema; 2 = likely no edema; 3 = likely edema; 4 = edema). Accuracy, sensitivity, and specificity for the detection of BME on DLCT were analyzed using MR findings as standard of reference. For the detection of BME in patients with OO, DLCT showed a sensitivity of 0.92, a specificity of 0.94, and an accuracy of 0.92 for both radiologists. Interreader agreement for the assessment of BME with DLCT was substantial (weighted κ = 0.78; 95% CI, 0.59, 0.94). DLCT with material-specific volume fraction maps allowed accurate detection of BME in patients with OO. This may spare patients additional examinations and facilitate the diagnosis of OO.
format Online
Article
Text
id pubmed-8227561
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82275612021-06-26 Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT Gassert, Florian T. Hammel, Johannes Hofmann, Felix C. Neumann, Jan von Schacky, Claudio E. Gassert, Felix G. Pfeiffer, Daniela Pfeiffer, Franz Makowski, Marcus R. Woertler, Klaus Gersing, Alexandra S. Schwaiger, Benedikt J. Diagnostics (Basel) Article The aim of this study is to assess whether perifocal bone marrow edema (BME) in patients with osteoid osteoma (OO) can be accurately detected on dual-layer spectral CT (DLCT) with three-material decomposition. To that end, 18 patients with OO (25.33 ± 12.44 years; 7 females) were pairwise-matched with 18 patients (26.72 ± 9.65 years; 9 females) admitted for suspected pathologies other than OO in the same anatomic location but negative imaging findings. All patients were examined with DLCT and MRI. DLCT data was decomposed into hydroxyapatite and water- and fat-equivalent volume fraction maps. Two radiologists assessed DLCT-based volume fraction maps for the presence of perifocal BME, using a Likert scale (1 = no edema; 2 = likely no edema; 3 = likely edema; 4 = edema). Accuracy, sensitivity, and specificity for the detection of BME on DLCT were analyzed using MR findings as standard of reference. For the detection of BME in patients with OO, DLCT showed a sensitivity of 0.92, a specificity of 0.94, and an accuracy of 0.92 for both radiologists. Interreader agreement for the assessment of BME with DLCT was substantial (weighted κ = 0.78; 95% CI, 0.59, 0.94). DLCT with material-specific volume fraction maps allowed accurate detection of BME in patients with OO. This may spare patients additional examinations and facilitate the diagnosis of OO. MDPI 2021-05-26 /pmc/articles/PMC8227561/ /pubmed/34073416 http://dx.doi.org/10.3390/diagnostics11060953 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gassert, Florian T.
Hammel, Johannes
Hofmann, Felix C.
Neumann, Jan
von Schacky, Claudio E.
Gassert, Felix G.
Pfeiffer, Daniela
Pfeiffer, Franz
Makowski, Marcus R.
Woertler, Klaus
Gersing, Alexandra S.
Schwaiger, Benedikt J.
Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT
title Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT
title_full Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT
title_fullStr Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT
title_full_unstemmed Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT
title_short Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT
title_sort detection of bone marrow edema in patients with osteoid osteoma using three-material decomposition with dual-layer spectral ct
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8227561/
https://www.ncbi.nlm.nih.gov/pubmed/34073416
http://dx.doi.org/10.3390/diagnostics11060953
work_keys_str_mv AT gassertfloriant detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT hammeljohannes detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT hofmannfelixc detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT neumannjan detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT vonschackyclaudioe detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT gassertfelixg detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT pfeifferdaniela detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT pfeifferfranz detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT makowskimarcusr detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT woertlerklaus detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT gersingalexandras detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct
AT schwaigerbenediktj detectionofbonemarrowedemainpatientswithosteoidosteomausingthreematerialdecompositionwithduallayerspectralct