Cargando…

A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid

A surgical microscope is large in size, which makes it impossible to be portable. The distance between the surgical microscope and the observation tissue is 15–30 cm, and the adjustment range of the right and left of the camera is a maximum of 30°. Therefore, the surgical microscope generates an att...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoon, Kicheol, Kim, Kwanggi, Lee, Seunghoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8228542/
https://www.ncbi.nlm.nih.gov/pubmed/34206028
http://dx.doi.org/10.3390/diagnostics11061014
_version_ 1783712766525177856
author Yoon, Kicheol
Kim, Kwanggi
Lee, Seunghoon
author_facet Yoon, Kicheol
Kim, Kwanggi
Lee, Seunghoon
author_sort Yoon, Kicheol
collection PubMed
description A surgical microscope is large in size, which makes it impossible to be portable. The distance between the surgical microscope and the observation tissue is 15–30 cm, and the adjustment range of the right and left of the camera is a maximum of 30°. Therefore, the surgical microscope generates an attenuation (above 58%) of irradiation of the optical source owing to the long working distance (WD). Moreover, the observation of tissue is affected because of dazzling by ambient light as the optical source power is strong (55 to 160 mW/cm(2)). Further, observation blind spot phenomena will occur due to the limitations in adjusting the right and left of the camera. Therefore, it is difficult to clearly observe the tumor. To overcome these problems, several studies on the handheld surgical microscope have been reported. In this study, a compact pen-type probe with a portable surgical microscope is presented. The proposed surgical microscope comprises a small and portable pen-type probe that can adjust the WD between the probe and the observed tissue. In addition, it allows the adjustment of the viewing angle and fluorescence brightness. The proposed probe has no blind spots or optical density loss.
format Online
Article
Text
id pubmed-8228542
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82285422021-06-26 A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid Yoon, Kicheol Kim, Kwanggi Lee, Seunghoon Diagnostics (Basel) Article A surgical microscope is large in size, which makes it impossible to be portable. The distance between the surgical microscope and the observation tissue is 15–30 cm, and the adjustment range of the right and left of the camera is a maximum of 30°. Therefore, the surgical microscope generates an attenuation (above 58%) of irradiation of the optical source owing to the long working distance (WD). Moreover, the observation of tissue is affected because of dazzling by ambient light as the optical source power is strong (55 to 160 mW/cm(2)). Further, observation blind spot phenomena will occur due to the limitations in adjusting the right and left of the camera. Therefore, it is difficult to clearly observe the tumor. To overcome these problems, several studies on the handheld surgical microscope have been reported. In this study, a compact pen-type probe with a portable surgical microscope is presented. The proposed surgical microscope comprises a small and portable pen-type probe that can adjust the WD between the probe and the observed tissue. In addition, it allows the adjustment of the viewing angle and fluorescence brightness. The proposed probe has no blind spots or optical density loss. MDPI 2021-06-01 /pmc/articles/PMC8228542/ /pubmed/34206028 http://dx.doi.org/10.3390/diagnostics11061014 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yoon, Kicheol
Kim, Kwanggi
Lee, Seunghoon
A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid
title A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid
title_full A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid
title_fullStr A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid
title_full_unstemmed A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid
title_short A Surgical Pen-Type Probe Design for Real-Time Optical Diagnosis of Tumor Status Using 5-Aminolevulinic Acid
title_sort surgical pen-type probe design for real-time optical diagnosis of tumor status using 5-aminolevulinic acid
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8228542/
https://www.ncbi.nlm.nih.gov/pubmed/34206028
http://dx.doi.org/10.3390/diagnostics11061014
work_keys_str_mv AT yoonkicheol asurgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid
AT kimkwanggi asurgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid
AT leeseunghoon asurgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid
AT yoonkicheol surgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid
AT kimkwanggi surgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid
AT leeseunghoon surgicalpentypeprobedesignforrealtimeopticaldiagnosisoftumorstatususing5aminolevulinicacid