Cargando…
Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN
The Compact Muon Solenoid (CMS) is a particle physics experiment situated on the Large Hadron Collider (LHC) at CERN, Switzerland. The CMS upgrade (planned for 2025) involves installing a new advanced sensor system within the CMS tracker, the centre of the detector closest to the particle collisions...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8228960/ https://www.ncbi.nlm.nih.gov/pubmed/34207833 http://dx.doi.org/10.3390/ma14123190 |
_version_ | 1783712864687620096 |
---|---|
author | Zaburda, George Onnela, Antti Cichy, Kamil Daguin, Jerome Lunt, Alexander J. G. |
author_facet | Zaburda, George Onnela, Antti Cichy, Kamil Daguin, Jerome Lunt, Alexander J. G. |
author_sort | Zaburda, George |
collection | PubMed |
description | The Compact Muon Solenoid (CMS) is a particle physics experiment situated on the Large Hadron Collider (LHC) at CERN, Switzerland. The CMS upgrade (planned for 2025) involves installing a new advanced sensor system within the CMS tracker, the centre of the detector closest to the particle collisions. The increased heat load associated with these sensors has required the design of an enhanced cooling system that exploits the latent heat of 40 bar CO(2). In order to minimise interaction with the incident radiation and improve the detector performance, the cooling pipes within this system need to be thin-walled (~100 μm) and strong enough to withstand these pressures. The purpose of this paper is to analyse the microstructure and mechanical properties of thin-walled cooling pipes currently in use in existing detectors to assess their potential for the tracker upgrade. In total, 22 different pipes were examined, which were composed of CuNi, SS316L, and Ti and were coated with Ni, Cu, and Au. The samples were characterised using computer tomography for 3D structural assessment, focused ion beam ring-core milling for microscale residual stress analysis, optical profilometry for surface roughness, optical microscopy for grain size analysis, and energy dispersive X-ray spectroscopy for elemental analysis. Overall, this examination demonstrated that the Ni- and Cu-coated SS316L tubing was optimal due to a combination of low residual stress (20 MPa axial and 5 MPa hoop absolute), low coating roughness (0.4 μm Ra), minimal elemental diffusion, and a small void fraction (1.4%). This result offers a crucial starting point for the ongoing thin-walled pipe selection, development, and pipe-joining research required for the CMS tracker upgrade, as well as the widespread use of CO(2) cooling systems in general. |
format | Online Article Text |
id | pubmed-8228960 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82289602021-06-26 Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN Zaburda, George Onnela, Antti Cichy, Kamil Daguin, Jerome Lunt, Alexander J. G. Materials (Basel) Article The Compact Muon Solenoid (CMS) is a particle physics experiment situated on the Large Hadron Collider (LHC) at CERN, Switzerland. The CMS upgrade (planned for 2025) involves installing a new advanced sensor system within the CMS tracker, the centre of the detector closest to the particle collisions. The increased heat load associated with these sensors has required the design of an enhanced cooling system that exploits the latent heat of 40 bar CO(2). In order to minimise interaction with the incident radiation and improve the detector performance, the cooling pipes within this system need to be thin-walled (~100 μm) and strong enough to withstand these pressures. The purpose of this paper is to analyse the microstructure and mechanical properties of thin-walled cooling pipes currently in use in existing detectors to assess their potential for the tracker upgrade. In total, 22 different pipes were examined, which were composed of CuNi, SS316L, and Ti and were coated with Ni, Cu, and Au. The samples were characterised using computer tomography for 3D structural assessment, focused ion beam ring-core milling for microscale residual stress analysis, optical profilometry for surface roughness, optical microscopy for grain size analysis, and energy dispersive X-ray spectroscopy for elemental analysis. Overall, this examination demonstrated that the Ni- and Cu-coated SS316L tubing was optimal due to a combination of low residual stress (20 MPa axial and 5 MPa hoop absolute), low coating roughness (0.4 μm Ra), minimal elemental diffusion, and a small void fraction (1.4%). This result offers a crucial starting point for the ongoing thin-walled pipe selection, development, and pipe-joining research required for the CMS tracker upgrade, as well as the widespread use of CO(2) cooling systems in general. MDPI 2021-06-09 /pmc/articles/PMC8228960/ /pubmed/34207833 http://dx.doi.org/10.3390/ma14123190 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zaburda, George Onnela, Antti Cichy, Kamil Daguin, Jerome Lunt, Alexander J. G. Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN |
title | Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN |
title_full | Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN |
title_fullStr | Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN |
title_full_unstemmed | Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN |
title_short | Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN |
title_sort | mechanical and microstructural characterisation of cooling pipes for the compact muon solenoid experiment at cern |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8228960/ https://www.ncbi.nlm.nih.gov/pubmed/34207833 http://dx.doi.org/10.3390/ma14123190 |
work_keys_str_mv | AT zaburdageorge mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern AT onnelaantti mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern AT cichykamil mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern AT daguinjerome mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern AT luntalexanderjg mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern |