Cargando…

Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN

The Compact Muon Solenoid (CMS) is a particle physics experiment situated on the Large Hadron Collider (LHC) at CERN, Switzerland. The CMS upgrade (planned for 2025) involves installing a new advanced sensor system within the CMS tracker, the centre of the detector closest to the particle collisions...

Descripción completa

Detalles Bibliográficos
Autores principales: Zaburda, George, Onnela, Antti, Cichy, Kamil, Daguin, Jerome, Lunt, Alexander J. G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8228960/
https://www.ncbi.nlm.nih.gov/pubmed/34207833
http://dx.doi.org/10.3390/ma14123190
_version_ 1783712864687620096
author Zaburda, George
Onnela, Antti
Cichy, Kamil
Daguin, Jerome
Lunt, Alexander J. G.
author_facet Zaburda, George
Onnela, Antti
Cichy, Kamil
Daguin, Jerome
Lunt, Alexander J. G.
author_sort Zaburda, George
collection PubMed
description The Compact Muon Solenoid (CMS) is a particle physics experiment situated on the Large Hadron Collider (LHC) at CERN, Switzerland. The CMS upgrade (planned for 2025) involves installing a new advanced sensor system within the CMS tracker, the centre of the detector closest to the particle collisions. The increased heat load associated with these sensors has required the design of an enhanced cooling system that exploits the latent heat of 40 bar CO(2). In order to minimise interaction with the incident radiation and improve the detector performance, the cooling pipes within this system need to be thin-walled (~100 μm) and strong enough to withstand these pressures. The purpose of this paper is to analyse the microstructure and mechanical properties of thin-walled cooling pipes currently in use in existing detectors to assess their potential for the tracker upgrade. In total, 22 different pipes were examined, which were composed of CuNi, SS316L, and Ti and were coated with Ni, Cu, and Au. The samples were characterised using computer tomography for 3D structural assessment, focused ion beam ring-core milling for microscale residual stress analysis, optical profilometry for surface roughness, optical microscopy for grain size analysis, and energy dispersive X-ray spectroscopy for elemental analysis. Overall, this examination demonstrated that the Ni- and Cu-coated SS316L tubing was optimal due to a combination of low residual stress (20 MPa axial and 5 MPa hoop absolute), low coating roughness (0.4 μm Ra), minimal elemental diffusion, and a small void fraction (1.4%). This result offers a crucial starting point for the ongoing thin-walled pipe selection, development, and pipe-joining research required for the CMS tracker upgrade, as well as the widespread use of CO(2) cooling systems in general.
format Online
Article
Text
id pubmed-8228960
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82289602021-06-26 Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN Zaburda, George Onnela, Antti Cichy, Kamil Daguin, Jerome Lunt, Alexander J. G. Materials (Basel) Article The Compact Muon Solenoid (CMS) is a particle physics experiment situated on the Large Hadron Collider (LHC) at CERN, Switzerland. The CMS upgrade (planned for 2025) involves installing a new advanced sensor system within the CMS tracker, the centre of the detector closest to the particle collisions. The increased heat load associated with these sensors has required the design of an enhanced cooling system that exploits the latent heat of 40 bar CO(2). In order to minimise interaction with the incident radiation and improve the detector performance, the cooling pipes within this system need to be thin-walled (~100 μm) and strong enough to withstand these pressures. The purpose of this paper is to analyse the microstructure and mechanical properties of thin-walled cooling pipes currently in use in existing detectors to assess their potential for the tracker upgrade. In total, 22 different pipes were examined, which were composed of CuNi, SS316L, and Ti and were coated with Ni, Cu, and Au. The samples were characterised using computer tomography for 3D structural assessment, focused ion beam ring-core milling for microscale residual stress analysis, optical profilometry for surface roughness, optical microscopy for grain size analysis, and energy dispersive X-ray spectroscopy for elemental analysis. Overall, this examination demonstrated that the Ni- and Cu-coated SS316L tubing was optimal due to a combination of low residual stress (20 MPa axial and 5 MPa hoop absolute), low coating roughness (0.4 μm Ra), minimal elemental diffusion, and a small void fraction (1.4%). This result offers a crucial starting point for the ongoing thin-walled pipe selection, development, and pipe-joining research required for the CMS tracker upgrade, as well as the widespread use of CO(2) cooling systems in general. MDPI 2021-06-09 /pmc/articles/PMC8228960/ /pubmed/34207833 http://dx.doi.org/10.3390/ma14123190 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zaburda, George
Onnela, Antti
Cichy, Kamil
Daguin, Jerome
Lunt, Alexander J. G.
Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN
title Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN
title_full Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN
title_fullStr Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN
title_full_unstemmed Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN
title_short Mechanical and Microstructural Characterisation of Cooling Pipes for the Compact Muon Solenoid Experiment at CERN
title_sort mechanical and microstructural characterisation of cooling pipes for the compact muon solenoid experiment at cern
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8228960/
https://www.ncbi.nlm.nih.gov/pubmed/34207833
http://dx.doi.org/10.3390/ma14123190
work_keys_str_mv AT zaburdageorge mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern
AT onnelaantti mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern
AT cichykamil mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern
AT daguinjerome mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern
AT luntalexanderjg mechanicalandmicrostructuralcharacterisationofcoolingpipesforthecompactmuonsolenoidexperimentatcern