Cargando…

Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy

BACKGROUND: Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim...

Descripción completa

Detalles Bibliográficos
Autores principales: Wagner, Franziska C., Reese, Sven, Gerlach, Kerstin, Böttcher, Peter, Mülling, Christoph K. W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8229380/
https://www.ncbi.nlm.nih.gov/pubmed/34172051
http://dx.doi.org/10.1186/s12917-021-02914-w
_version_ 1783712963698360320
author Wagner, Franziska C.
Reese, Sven
Gerlach, Kerstin
Böttcher, Peter
Mülling, Christoph K. W.
author_facet Wagner, Franziska C.
Reese, Sven
Gerlach, Kerstin
Böttcher, Peter
Mülling, Christoph K. W.
author_sort Wagner, Franziska C.
collection PubMed
description BACKGROUND: Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min. RESULTS: A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance. CONCLUSION: In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12917-021-02914-w.
format Online
Article
Text
id pubmed-8229380
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-82293802021-06-28 Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy Wagner, Franziska C. Reese, Sven Gerlach, Kerstin Böttcher, Peter Mülling, Christoph K. W. BMC Vet Res Research Article BACKGROUND: Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min. RESULTS: A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance. CONCLUSION: In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12917-021-02914-w. BioMed Central 2021-06-25 /pmc/articles/PMC8229380/ /pubmed/34172051 http://dx.doi.org/10.1186/s12917-021-02914-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Wagner, Franziska C.
Reese, Sven
Gerlach, Kerstin
Böttcher, Peter
Mülling, Christoph K. W.
Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy
title Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy
title_full Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy
title_fullStr Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy
title_full_unstemmed Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy
title_short Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy
title_sort cyclic tensile tests of shetland pony superficial digital flexor tendons (sdfts) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8229380/
https://www.ncbi.nlm.nih.gov/pubmed/34172051
http://dx.doi.org/10.1186/s12917-021-02914-w
work_keys_str_mv AT wagnerfranziskac cyclictensiletestsofshetlandponysuperficialdigitalflexortendonssdftswithanoptimizedcryoclampcombinedwithbiplanarhighspeedfluoroscopy
AT reesesven cyclictensiletestsofshetlandponysuperficialdigitalflexortendonssdftswithanoptimizedcryoclampcombinedwithbiplanarhighspeedfluoroscopy
AT gerlachkerstin cyclictensiletestsofshetlandponysuperficialdigitalflexortendonssdftswithanoptimizedcryoclampcombinedwithbiplanarhighspeedfluoroscopy
AT bottcherpeter cyclictensiletestsofshetlandponysuperficialdigitalflexortendonssdftswithanoptimizedcryoclampcombinedwithbiplanarhighspeedfluoroscopy
AT mullingchristophkw cyclictensiletestsofshetlandponysuperficialdigitalflexortendonssdftswithanoptimizedcryoclampcombinedwithbiplanarhighspeedfluoroscopy