Image Registration of (18)F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation

We evaluated the benefits of the MotionFree algorithm through phantom and patient studies. The various sizes of phantom and vacuum vials were linked to RPM moving with or without MotionFree application. A total of 600 patients were divided into six groups by breathing protocols and CT scanning time....

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Deok-Hwan, Yoo, Eun-Hye, Hong, Ui-Seong, Kim, Jun-Hyeok, Ko, Young-Heon, Moon, Seung-Cheol, Cheon, Miju, Yoo, Jang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8229608/
https://www.ncbi.nlm.nih.gov/pubmed/34199705
http://dx.doi.org/10.3390/healthcare9060669
_version_ 1783713017904496640
author Kim, Deok-Hwan
Yoo, Eun-Hye
Hong, Ui-Seong
Kim, Jun-Hyeok
Ko, Young-Heon
Moon, Seung-Cheol
Cheon, Miju
Yoo, Jang
author_facet Kim, Deok-Hwan
Yoo, Eun-Hye
Hong, Ui-Seong
Kim, Jun-Hyeok
Ko, Young-Heon
Moon, Seung-Cheol
Cheon, Miju
Yoo, Jang
author_sort Kim, Deok-Hwan
collection PubMed
description We evaluated the benefits of the MotionFree algorithm through phantom and patient studies. The various sizes of phantom and vacuum vials were linked to RPM moving with or without MotionFree application. A total of 600 patients were divided into six groups by breathing protocols and CT scanning time. Breathing protocols were applied as follows: (a) patients who underwent scanning without any breathing instructions; (b) patients who were instructed to hold their breath after expiration during CT scan; and (c) patients who were instructed to breathe naturally. The length of PET/CT misregistration was measured and we defined the misregistration when it exceeded 10 mm. In the phantom tests, the images produced by the MotionFree algorithm were observed to have excellent agreement with static images. There were significant differences in PET/CT misregistration according to CT scanning time and each breathing protocol. When applying the type (c) protocol, decreasing the CT scanning time significantly reduced the frequency and length of misregistrations (p < 0.05). The MotionFree application is able to correct respiratory motion artifacts and to accurately quantify lesions. The shorter time of CT scan can reduce the frequency, and the natural breathing protocol also decreases the lengths of misregistrations.
format Online
Article
Text
id pubmed-8229608
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82296082021-06-26 Image Registration of (18)F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation Kim, Deok-Hwan Yoo, Eun-Hye Hong, Ui-Seong Kim, Jun-Hyeok Ko, Young-Heon Moon, Seung-Cheol Cheon, Miju Yoo, Jang Healthcare (Basel) Article We evaluated the benefits of the MotionFree algorithm through phantom and patient studies. The various sizes of phantom and vacuum vials were linked to RPM moving with or without MotionFree application. A total of 600 patients were divided into six groups by breathing protocols and CT scanning time. Breathing protocols were applied as follows: (a) patients who underwent scanning without any breathing instructions; (b) patients who were instructed to hold their breath after expiration during CT scan; and (c) patients who were instructed to breathe naturally. The length of PET/CT misregistration was measured and we defined the misregistration when it exceeded 10 mm. In the phantom tests, the images produced by the MotionFree algorithm were observed to have excellent agreement with static images. There were significant differences in PET/CT misregistration according to CT scanning time and each breathing protocol. When applying the type (c) protocol, decreasing the CT scanning time significantly reduced the frequency and length of misregistrations (p < 0.05). The MotionFree application is able to correct respiratory motion artifacts and to accurately quantify lesions. The shorter time of CT scan can reduce the frequency, and the natural breathing protocol also decreases the lengths of misregistrations. MDPI 2021-06-04 /pmc/articles/PMC8229608/ /pubmed/34199705 http://dx.doi.org/10.3390/healthcare9060669 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Deok-Hwan
Yoo, Eun-Hye
Hong, Ui-Seong
Kim, Jun-Hyeok
Ko, Young-Heon
Moon, Seung-Cheol
Cheon, Miju
Yoo, Jang
Image Registration of (18)F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation
title Image Registration of (18)F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation
title_full Image Registration of (18)F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation
title_fullStr Image Registration of (18)F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation
title_full_unstemmed Image Registration of (18)F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation
title_short Image Registration of (18)F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation
title_sort image registration of (18)f-fdg pet/ct using the motionfree algorithm and ct protocols through phantom study and clinical evaluation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8229608/
https://www.ncbi.nlm.nih.gov/pubmed/34199705
http://dx.doi.org/10.3390/healthcare9060669
work_keys_str_mv AT kimdeokhwan imageregistrationof18ffdgpetctusingthemotionfreealgorithmandctprotocolsthroughphantomstudyandclinicalevaluation
AT yooeunhye imageregistrationof18ffdgpetctusingthemotionfreealgorithmandctprotocolsthroughphantomstudyandclinicalevaluation
AT honguiseong imageregistrationof18ffdgpetctusingthemotionfreealgorithmandctprotocolsthroughphantomstudyandclinicalevaluation
AT kimjunhyeok imageregistrationof18ffdgpetctusingthemotionfreealgorithmandctprotocolsthroughphantomstudyandclinicalevaluation
AT koyoungheon imageregistrationof18ffdgpetctusingthemotionfreealgorithmandctprotocolsthroughphantomstudyandclinicalevaluation
AT moonseungcheol imageregistrationof18ffdgpetctusingthemotionfreealgorithmandctprotocolsthroughphantomstudyandclinicalevaluation
AT cheonmiju imageregistrationof18ffdgpetctusingthemotionfreealgorithmandctprotocolsthroughphantomstudyandclinicalevaluation
AT yoojang imageregistrationof18ffdgpetctusingthemotionfreealgorithmandctprotocolsthroughphantomstudyandclinicalevaluation