Measurement of Exhaled Nitric Oxide in 456 Lung Cancer Patients Using a Ringdown FENO Analyzer

The objective of this study was to investigate the clinical value of exhaled nitric oxide (NO) for diagnosing lung cancer patients by using a relatively large sample. An online and near-real-time ringdown exhaled NO analyzer calibrated by an electrochemical sensor at clinical was used for breath ana...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Jing, Li, Qingyuan, Wei, Xin, Chen, Qing, Sun, Meixiu, Li, Yingxin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8230208/
https://www.ncbi.nlm.nih.gov/pubmed/34072964
http://dx.doi.org/10.3390/metabo11060352
Descripción
Sumario:The objective of this study was to investigate the clinical value of exhaled nitric oxide (NO) for diagnosing lung cancer patients by using a relatively large sample. An online and near-real-time ringdown exhaled NO analyzer calibrated by an electrochemical sensor at clinical was used for breath analysis. A total of 740 breath samples from 284 healthy control subjects (H) and 456 lung cancer patients (LC) were collected. The recorded data included exhaled NO, medications taken within the last half month, demographics, fasting status and smoking status. The LC had a significantly higher level of exhaled NO than the H (H: 21.0 ± 12.1 ppb vs. LC: 34.1 ± 17.2 ppb). The area under the receiver operating characteristic curve for exhaled NO predicting LC and H was 0.728 (sensitivity was 0.798; specificity was 0.55). There was no significant difference in exhaled NO level between groups divided by different types of LC, tumor node metastasis (TNM) stage, sex, smoking status, age, body mass index (BMI) or fasting status. Exhaled NO level alone is not a useful clinical tool for identifying lung cancer, but it should be considered when developing a diagnosis model of lung cancer by using breath analysis.