Cargando…
Resistance to Fracture of Lithium Disilicate Feldspathic Restorations Manufactured Using a CAD/CAM System and Crystallized with Different Thermal Units and Programs
The aim of this study was to determine the resistance to fracture of feldspathic restorations with lithium disilicate and crystallized with different ovens and programs. Methods: Sixty monolithic restorations (LD) (EMAX CAD™ LT, Ivoclar-Vivadent™) were designed with the same parameters and milled wi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8230546/ https://www.ncbi.nlm.nih.gov/pubmed/34200881 http://dx.doi.org/10.3390/ma14123215 |
_version_ | 1783713235896107008 |
---|---|
author | Abad-Coronel, Cristian Ordoñez Balladares, Andrea Fajardo, Jorge I. Martín Biedma, Benjamín José |
author_facet | Abad-Coronel, Cristian Ordoñez Balladares, Andrea Fajardo, Jorge I. Martín Biedma, Benjamín José |
author_sort | Abad-Coronel, Cristian |
collection | PubMed |
description | The aim of this study was to determine the resistance to fracture of feldspathic restorations with lithium disilicate and crystallized with different ovens and programs. Methods: Sixty monolithic restorations (LD) (EMAX CAD™ LT, Ivoclar-Vivadent™) were designed with the same parameters and milled with a CAD/CAM system (CEREC SW 5.1, CEREC MCXL, Dentsply-Sirona™, Bensheim). Each restoration was randomly assigned by randomization software (RANDNUM) to one of the three groups: (a) (NF) Oven P310 (Ivoclar, Vivadent) normal crystallization program, (b) (FF) Ivoclar P310 oven (Ivoclar-Vivadent™) rapid crystallization program, or (c) (SF) SpeedFire oven (Dentsply-Sirona™). Results: There were statistically significant differences between the groups (ANOVA, p < 0.05). The NF and FF groups showed the highest values of resistance to fracture, with statistically significant differences with the SF group. Conclusions: Using a furnace from the same dental company with predetermined programs from the material manufacturer, as well as using a predetermined program for rapid crystallization, has no effect on fracture resistance, and would save clinical time when performing ceramic restorations with lithium disilicate, while keeping their mechanical properties. |
format | Online Article Text |
id | pubmed-8230546 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82305462021-06-26 Resistance to Fracture of Lithium Disilicate Feldspathic Restorations Manufactured Using a CAD/CAM System and Crystallized with Different Thermal Units and Programs Abad-Coronel, Cristian Ordoñez Balladares, Andrea Fajardo, Jorge I. Martín Biedma, Benjamín José Materials (Basel) Article The aim of this study was to determine the resistance to fracture of feldspathic restorations with lithium disilicate and crystallized with different ovens and programs. Methods: Sixty monolithic restorations (LD) (EMAX CAD™ LT, Ivoclar-Vivadent™) were designed with the same parameters and milled with a CAD/CAM system (CEREC SW 5.1, CEREC MCXL, Dentsply-Sirona™, Bensheim). Each restoration was randomly assigned by randomization software (RANDNUM) to one of the three groups: (a) (NF) Oven P310 (Ivoclar, Vivadent) normal crystallization program, (b) (FF) Ivoclar P310 oven (Ivoclar-Vivadent™) rapid crystallization program, or (c) (SF) SpeedFire oven (Dentsply-Sirona™). Results: There were statistically significant differences between the groups (ANOVA, p < 0.05). The NF and FF groups showed the highest values of resistance to fracture, with statistically significant differences with the SF group. Conclusions: Using a furnace from the same dental company with predetermined programs from the material manufacturer, as well as using a predetermined program for rapid crystallization, has no effect on fracture resistance, and would save clinical time when performing ceramic restorations with lithium disilicate, while keeping their mechanical properties. MDPI 2021-06-10 /pmc/articles/PMC8230546/ /pubmed/34200881 http://dx.doi.org/10.3390/ma14123215 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Abad-Coronel, Cristian Ordoñez Balladares, Andrea Fajardo, Jorge I. Martín Biedma, Benjamín José Resistance to Fracture of Lithium Disilicate Feldspathic Restorations Manufactured Using a CAD/CAM System and Crystallized with Different Thermal Units and Programs |
title | Resistance to Fracture of Lithium Disilicate Feldspathic Restorations Manufactured Using a CAD/CAM System and Crystallized with Different Thermal Units and Programs |
title_full | Resistance to Fracture of Lithium Disilicate Feldspathic Restorations Manufactured Using a CAD/CAM System and Crystallized with Different Thermal Units and Programs |
title_fullStr | Resistance to Fracture of Lithium Disilicate Feldspathic Restorations Manufactured Using a CAD/CAM System and Crystallized with Different Thermal Units and Programs |
title_full_unstemmed | Resistance to Fracture of Lithium Disilicate Feldspathic Restorations Manufactured Using a CAD/CAM System and Crystallized with Different Thermal Units and Programs |
title_short | Resistance to Fracture of Lithium Disilicate Feldspathic Restorations Manufactured Using a CAD/CAM System and Crystallized with Different Thermal Units and Programs |
title_sort | resistance to fracture of lithium disilicate feldspathic restorations manufactured using a cad/cam system and crystallized with different thermal units and programs |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8230546/ https://www.ncbi.nlm.nih.gov/pubmed/34200881 http://dx.doi.org/10.3390/ma14123215 |
work_keys_str_mv | AT abadcoronelcristian resistancetofractureoflithiumdisilicatefeldspathicrestorationsmanufacturedusingacadcamsystemandcrystallizedwithdifferentthermalunitsandprograms AT ordonezballadaresandrea resistancetofractureoflithiumdisilicatefeldspathicrestorationsmanufacturedusingacadcamsystemandcrystallizedwithdifferentthermalunitsandprograms AT fajardojorgei resistancetofractureoflithiumdisilicatefeldspathicrestorationsmanufacturedusingacadcamsystemandcrystallizedwithdifferentthermalunitsandprograms AT martinbiedmabenjaminjose resistancetofractureoflithiumdisilicatefeldspathicrestorationsmanufacturedusingacadcamsystemandcrystallizedwithdifferentthermalunitsandprograms |