Cargando…

Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology

Respiratory rate (RR) is typically the first vital sign to change when a patient decompensates. Despite this, RR is often monitored infrequently and inaccurately. The Circadia Contactless Breathing Monitor™ (model C100) is a novel device that uses ultra-wideband radar to monitor RR continuously and...

Descripción completa

Detalles Bibliográficos
Autores principales: Lauteslager, Timo, Maslik, Michal, Siddiqui, Fares, Marfani, Saad, Leschziner, Guy D., Williams, Adrian J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8230718/
https://www.ncbi.nlm.nih.gov/pubmed/34207961
http://dx.doi.org/10.3390/s21124027
_version_ 1783713277110386688
author Lauteslager, Timo
Maslik, Michal
Siddiqui, Fares
Marfani, Saad
Leschziner, Guy D.
Williams, Adrian J.
author_facet Lauteslager, Timo
Maslik, Michal
Siddiqui, Fares
Marfani, Saad
Leschziner, Guy D.
Williams, Adrian J.
author_sort Lauteslager, Timo
collection PubMed
description Respiratory rate (RR) is typically the first vital sign to change when a patient decompensates. Despite this, RR is often monitored infrequently and inaccurately. The Circadia Contactless Breathing Monitor™ (model C100) is a novel device that uses ultra-wideband radar to monitor RR continuously and un-obtrusively. Performance of the Circadia Monitor was assessed by direct comparison to manually scored reference data. Data were collected across a range of clinical and non-clinical settings, considering a broad range of user characteristics and use cases, in a total of 50 subjects. Bland–Altman analysis showed high agreement with the gold standard reference for all study data, and agreement fell within the predefined acceptance criteria of ±5 breaths per minute (BrPM). The 95% limits of agreement were −3.0 to 1.3 BrPM for a nonprobability sample of subjects while awake, −2.3 to 1.7 BrPM for a clinical sample of subjects while asleep, and −1.2 to 0.7 BrPM for a sample of healthy subjects while asleep. Accuracy rate, using an error margin of ±2 BrPM, was found to be 90% or higher. Results demonstrate that the Circadia Monitor can effectively and efficiently be used for accurate spot measurements and continuous bedside monitoring of RR in low acuity settings, such as the nursing home or hospital ward, or for remote patient monitoring.
format Online
Article
Text
id pubmed-8230718
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82307182021-06-26 Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology Lauteslager, Timo Maslik, Michal Siddiqui, Fares Marfani, Saad Leschziner, Guy D. Williams, Adrian J. Sensors (Basel) Article Respiratory rate (RR) is typically the first vital sign to change when a patient decompensates. Despite this, RR is often monitored infrequently and inaccurately. The Circadia Contactless Breathing Monitor™ (model C100) is a novel device that uses ultra-wideband radar to monitor RR continuously and un-obtrusively. Performance of the Circadia Monitor was assessed by direct comparison to manually scored reference data. Data were collected across a range of clinical and non-clinical settings, considering a broad range of user characteristics and use cases, in a total of 50 subjects. Bland–Altman analysis showed high agreement with the gold standard reference for all study data, and agreement fell within the predefined acceptance criteria of ±5 breaths per minute (BrPM). The 95% limits of agreement were −3.0 to 1.3 BrPM for a nonprobability sample of subjects while awake, −2.3 to 1.7 BrPM for a clinical sample of subjects while asleep, and −1.2 to 0.7 BrPM for a sample of healthy subjects while asleep. Accuracy rate, using an error margin of ±2 BrPM, was found to be 90% or higher. Results demonstrate that the Circadia Monitor can effectively and efficiently be used for accurate spot measurements and continuous bedside monitoring of RR in low acuity settings, such as the nursing home or hospital ward, or for remote patient monitoring. MDPI 2021-06-11 /pmc/articles/PMC8230718/ /pubmed/34207961 http://dx.doi.org/10.3390/s21124027 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lauteslager, Timo
Maslik, Michal
Siddiqui, Fares
Marfani, Saad
Leschziner, Guy D.
Williams, Adrian J.
Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology
title Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology
title_full Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology
title_fullStr Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology
title_full_unstemmed Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology
title_short Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology
title_sort validation of a new contactless and continuous respiratory rate monitoring device based on ultra-wideband radar technology
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8230718/
https://www.ncbi.nlm.nih.gov/pubmed/34207961
http://dx.doi.org/10.3390/s21124027
work_keys_str_mv AT lauteslagertimo validationofanewcontactlessandcontinuousrespiratoryratemonitoringdevicebasedonultrawidebandradartechnology
AT maslikmichal validationofanewcontactlessandcontinuousrespiratoryratemonitoringdevicebasedonultrawidebandradartechnology
AT siddiquifares validationofanewcontactlessandcontinuousrespiratoryratemonitoringdevicebasedonultrawidebandradartechnology
AT marfanisaad validationofanewcontactlessandcontinuousrespiratoryratemonitoringdevicebasedonultrawidebandradartechnology
AT leschzinerguyd validationofanewcontactlessandcontinuousrespiratoryratemonitoringdevicebasedonultrawidebandradartechnology
AT williamsadrianj validationofanewcontactlessandcontinuousrespiratoryratemonitoringdevicebasedonultrawidebandradartechnology