Cargando…

A Ratiometric Optical Dual Sensor for the Simultaneous Detection of Oxygen and Carbon Dioxide

Simultaneous detection of carbon dioxide (CO(2)) and oxygen (O(2)) has attracted considerable interest since CO(2) and O(2) play key roles in various industrial and domestic applications. In this study, a new approach based on a fluorescence ratiometric referencing method was reported to develop an...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumar, Divyanshu, Chu, Cheng-Shane
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8231558/
https://www.ncbi.nlm.nih.gov/pubmed/34204697
http://dx.doi.org/10.3390/s21124057
_version_ 1783713452438585344
author Kumar, Divyanshu
Chu, Cheng-Shane
author_facet Kumar, Divyanshu
Chu, Cheng-Shane
author_sort Kumar, Divyanshu
collection PubMed
description Simultaneous detection of carbon dioxide (CO(2)) and oxygen (O(2)) has attracted considerable interest since CO(2) and O(2) play key roles in various industrial and domestic applications. In this study, a new approach based on a fluorescence ratiometric referencing method was reported to develop an optical dual sensor where platinum (II) meso-tetrakis(pentafluorophenyl)porphyrin (PtTFPP) complex used as the O(2)-sensitive dye, CdSe/ZnS quantum dots (QDs) combined with phenol red used as the CO(2)-sensitive dye, and CdSe/ZnS QDs used as the reference dye for the simultaneous detection of O(2) and CO(2). All the dyes were immobilized in a gas-permeable matrix poly (isobutyl methacrylate) (PolyIBM) and subjected to excitation using a 380 nm LED. The as-obtained distinct fluorescence spectral intensities were alternately exposed to analyte gases to observe changes in the fluorescence intensity. In the presence of O(2), the fluorescence intensity of the Pt (II) complex was considerably quenched, while in the presence of CO(2), the fluorescence intensity of QDs was increased. The corresponding ratiometric sensitivities of the optical dual sensor for O(2) and CO(2) were approximately 13 and 144, respectively. In addition, the response and recovery for O(2) and CO(2) were calculated to be 10 s/35 s and 20 s/60 s, respectively. Thus, a ratiometric optical dual gas sensor for the simultaneous detection of O(2) and CO(2) was successfully developed. Effects of spurious fluctuations in the intensity of external and excitation sources were suppressed by the ratiometric sensing approach.
format Online
Article
Text
id pubmed-8231558
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82315582021-06-26 A Ratiometric Optical Dual Sensor for the Simultaneous Detection of Oxygen and Carbon Dioxide Kumar, Divyanshu Chu, Cheng-Shane Sensors (Basel) Communication Simultaneous detection of carbon dioxide (CO(2)) and oxygen (O(2)) has attracted considerable interest since CO(2) and O(2) play key roles in various industrial and domestic applications. In this study, a new approach based on a fluorescence ratiometric referencing method was reported to develop an optical dual sensor where platinum (II) meso-tetrakis(pentafluorophenyl)porphyrin (PtTFPP) complex used as the O(2)-sensitive dye, CdSe/ZnS quantum dots (QDs) combined with phenol red used as the CO(2)-sensitive dye, and CdSe/ZnS QDs used as the reference dye for the simultaneous detection of O(2) and CO(2). All the dyes were immobilized in a gas-permeable matrix poly (isobutyl methacrylate) (PolyIBM) and subjected to excitation using a 380 nm LED. The as-obtained distinct fluorescence spectral intensities were alternately exposed to analyte gases to observe changes in the fluorescence intensity. In the presence of O(2), the fluorescence intensity of the Pt (II) complex was considerably quenched, while in the presence of CO(2), the fluorescence intensity of QDs was increased. The corresponding ratiometric sensitivities of the optical dual sensor for O(2) and CO(2) were approximately 13 and 144, respectively. In addition, the response and recovery for O(2) and CO(2) were calculated to be 10 s/35 s and 20 s/60 s, respectively. Thus, a ratiometric optical dual gas sensor for the simultaneous detection of O(2) and CO(2) was successfully developed. Effects of spurious fluctuations in the intensity of external and excitation sources were suppressed by the ratiometric sensing approach. MDPI 2021-06-12 /pmc/articles/PMC8231558/ /pubmed/34204697 http://dx.doi.org/10.3390/s21124057 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Kumar, Divyanshu
Chu, Cheng-Shane
A Ratiometric Optical Dual Sensor for the Simultaneous Detection of Oxygen and Carbon Dioxide
title A Ratiometric Optical Dual Sensor for the Simultaneous Detection of Oxygen and Carbon Dioxide
title_full A Ratiometric Optical Dual Sensor for the Simultaneous Detection of Oxygen and Carbon Dioxide
title_fullStr A Ratiometric Optical Dual Sensor for the Simultaneous Detection of Oxygen and Carbon Dioxide
title_full_unstemmed A Ratiometric Optical Dual Sensor for the Simultaneous Detection of Oxygen and Carbon Dioxide
title_short A Ratiometric Optical Dual Sensor for the Simultaneous Detection of Oxygen and Carbon Dioxide
title_sort ratiometric optical dual sensor for the simultaneous detection of oxygen and carbon dioxide
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8231558/
https://www.ncbi.nlm.nih.gov/pubmed/34204697
http://dx.doi.org/10.3390/s21124057
work_keys_str_mv AT kumardivyanshu aratiometricopticaldualsensorforthesimultaneousdetectionofoxygenandcarbondioxide
AT chuchengshane aratiometricopticaldualsensorforthesimultaneousdetectionofoxygenandcarbondioxide
AT kumardivyanshu ratiometricopticaldualsensorforthesimultaneousdetectionofoxygenandcarbondioxide
AT chuchengshane ratiometricopticaldualsensorforthesimultaneousdetectionofoxygenandcarbondioxide