Anisotropy of the Radiation Field Following Canine Sn-117m Treatment

Tin-117m ((117m)Sn) is used to treated dogs with osteoarthritic joints by radiosynoviorthesis. The internal conversion and Auger electrons emitted by the (117m)Sn provide the therapeutic effect. Sn-117m also emits gamma rays, of which the most significant is 158.6 keV. The external radiation field a...

Descripción completa

Detalles Bibliográficos
Autores principales: Arno, Matthew G., Simon, Jaime, Stevenson, Nigel, Donecker, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8231667/
https://www.ncbi.nlm.nih.gov/pubmed/34169926
http://dx.doi.org/10.1097/HP.0000000000001428
_version_ 1783713477239504896
author Arno, Matthew G.
Simon, Jaime
Stevenson, Nigel
Donecker, John
author_facet Arno, Matthew G.
Simon, Jaime
Stevenson, Nigel
Donecker, John
author_sort Arno, Matthew G.
collection PubMed
description Tin-117m ((117m)Sn) is used to treated dogs with osteoarthritic joints by radiosynoviorthesis. The internal conversion and Auger electrons emitted by the (117m)Sn provide the therapeutic effect. Sn-117m also emits gamma rays, of which the most significant is 158.6 keV. The external radiation field around a treated dog is of interest to limit the dose to the owners/caretakers of the dog. The dog’s torso attenuates the radiation being emitted toward the opposite side of the dog’s body. This leads to a radiation field that is significantly non-isotropic. This study characterizes the anisotropy of this field to permit maximum dose rate measurements to be used to calculate the dose to individuals in the vicinity of the dog. Measurements were made in nine directions and at two distances, 0.3 and 1.0 m, to characterize common distances and spatial orientations for human-dog interactions. From these measurements, the percent reduction in the average dose rate compared to the maximum dose rate was determined. From a radiation safety perspective, the important factor is the minimum amount of shielding effectiveness or percent reduction that can be expected. A reasonable measure for this value is the fifth percentile of the shielding effectiveness distribution. The fifth percentile shielding effectiveness measures are 27% and 21% at 0.3 and 1.0 m, respectively.
format Online
Article
Text
id pubmed-8231667
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-82316672021-07-06 Anisotropy of the Radiation Field Following Canine Sn-117m Treatment Arno, Matthew G. Simon, Jaime Stevenson, Nigel Donecker, John Health Phys Papers Tin-117m ((117m)Sn) is used to treated dogs with osteoarthritic joints by radiosynoviorthesis. The internal conversion and Auger electrons emitted by the (117m)Sn provide the therapeutic effect. Sn-117m also emits gamma rays, of which the most significant is 158.6 keV. The external radiation field around a treated dog is of interest to limit the dose to the owners/caretakers of the dog. The dog’s torso attenuates the radiation being emitted toward the opposite side of the dog’s body. This leads to a radiation field that is significantly non-isotropic. This study characterizes the anisotropy of this field to permit maximum dose rate measurements to be used to calculate the dose to individuals in the vicinity of the dog. Measurements were made in nine directions and at two distances, 0.3 and 1.0 m, to characterize common distances and spatial orientations for human-dog interactions. From these measurements, the percent reduction in the average dose rate compared to the maximum dose rate was determined. From a radiation safety perspective, the important factor is the minimum amount of shielding effectiveness or percent reduction that can be expected. A reasonable measure for this value is the fifth percentile of the shielding effectiveness distribution. The fifth percentile shielding effectiveness measures are 27% and 21% at 0.3 and 1.0 m, respectively. Lippincott Williams & Wilkins 2021-08 2021-05-14 /pmc/articles/PMC8231667/ /pubmed/34169926 http://dx.doi.org/10.1097/HP.0000000000001428 Text en Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Health Physics Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Papers
Arno, Matthew G.
Simon, Jaime
Stevenson, Nigel
Donecker, John
Anisotropy of the Radiation Field Following Canine Sn-117m Treatment
title Anisotropy of the Radiation Field Following Canine Sn-117m Treatment
title_full Anisotropy of the Radiation Field Following Canine Sn-117m Treatment
title_fullStr Anisotropy of the Radiation Field Following Canine Sn-117m Treatment
title_full_unstemmed Anisotropy of the Radiation Field Following Canine Sn-117m Treatment
title_short Anisotropy of the Radiation Field Following Canine Sn-117m Treatment
title_sort anisotropy of the radiation field following canine sn-117m treatment
topic Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8231667/
https://www.ncbi.nlm.nih.gov/pubmed/34169926
http://dx.doi.org/10.1097/HP.0000000000001428
work_keys_str_mv AT arnomatthewg anisotropyoftheradiationfieldfollowingcaninesn117mtreatment
AT simonjaime anisotropyoftheradiationfieldfollowingcaninesn117mtreatment
AT stevensonnigel anisotropyoftheradiationfieldfollowingcaninesn117mtreatment
AT doneckerjohn anisotropyoftheradiationfieldfollowingcaninesn117mtreatment