Cargando…

Efficient Matrix Cleanup of Soft-Gel-Type Dietary Supplements for Rapid Screening of 92 Illegal Adulterants Using EMR-Lipid dSPE and UHPLC-Q/TOF-MS

An efficient matrix cleanup method was developed for the rapid screening of 92 illegal adulterants (25 erectile dysfunction drugs, 15 steroids, seven anabolic steroids, 12 antihistamines, 12 nonsteroidal anti-inflammatory drugs (NSAIDs), four diuretics, and 17 weight-loss drugs) in soft-gel-type sup...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Beom Hee, Lee, Wonwoong, Kim, You Lee, Lee, Ji Hyun, Hong, Jongki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8232078/
https://www.ncbi.nlm.nih.gov/pubmed/34203614
http://dx.doi.org/10.3390/ph14060570
_version_ 1783713557898067968
author Kim, Beom Hee
Lee, Wonwoong
Kim, You Lee
Lee, Ji Hyun
Hong, Jongki
author_facet Kim, Beom Hee
Lee, Wonwoong
Kim, You Lee
Lee, Ji Hyun
Hong, Jongki
author_sort Kim, Beom Hee
collection PubMed
description An efficient matrix cleanup method was developed for the rapid screening of 92 illegal adulterants (25 erectile dysfunction drugs, 15 steroids, seven anabolic steroids, 12 antihistamines, 12 nonsteroidal anti-inflammatory drugs (NSAIDs), four diuretics, and 17 weight-loss drugs) in soft-gel-type supplements by ultra-high performance liquid chromatography-quadrupole/time of flight-mass spectrometry (UHPLC-Q/TOF-MS). As representative green chemistry methods, three sample preparation methods (dispersive liquid-liquid microextraction (DLLME), “quick, easy, cheap, effective, rugged, and safe” dispersive solid-phase extraction (QuEChERS-dSPE), and enhanced matrix removal-lipid (EMR-Lipid) dSPE) were evaluated for matrix removal efficiency, recovery rate, and matrix effect. In this study, EMR-Lipid dSPE was shown to effectively remove complicated matrix contents in soft-gels, compared to DLLME and QuEChERS-dSPE. For the rapid screening of a wide range of adulterants, extracted common ion chromatogram (ECIC) and neutral loss scan (NLS) based on specific common MS/MS fragments were applied to randomly collected soft-gel-type dietary supplement samples using UHPLC-Q/TOF-MS. Both ECICs and NLSs enabled rapid and simple screening of multi-class adulterants and could be an alternative to the multiple reaction monitoring (MRM) method. The developed method was validated in terms of limit of detection (LOD), precision, accuracy, recovery, and matrix effects. The range of LODs was 0.1–16 ng/g. The overall precision values were within 0.09–14.65%. The accuracy ranged from 81.6% to 116.6%. The recoveries and matrix effects of 92 illegal adulterants ranged within 16.9–119.4% and 69.8–114.8%, respectively. The established method was successfully applied to screen and identify 92 illegal adulterants in soft-gels. This method can be a promising tool for the high-throughput screening of various adulterants in dietary supplements and could be used as a more environmentally friendly routine analytical method for screening dietary supplements illegally adulterated with multi-class drug substances.
format Online
Article
Text
id pubmed-8232078
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82320782021-06-26 Efficient Matrix Cleanup of Soft-Gel-Type Dietary Supplements for Rapid Screening of 92 Illegal Adulterants Using EMR-Lipid dSPE and UHPLC-Q/TOF-MS Kim, Beom Hee Lee, Wonwoong Kim, You Lee Lee, Ji Hyun Hong, Jongki Pharmaceuticals (Basel) Article An efficient matrix cleanup method was developed for the rapid screening of 92 illegal adulterants (25 erectile dysfunction drugs, 15 steroids, seven anabolic steroids, 12 antihistamines, 12 nonsteroidal anti-inflammatory drugs (NSAIDs), four diuretics, and 17 weight-loss drugs) in soft-gel-type supplements by ultra-high performance liquid chromatography-quadrupole/time of flight-mass spectrometry (UHPLC-Q/TOF-MS). As representative green chemistry methods, three sample preparation methods (dispersive liquid-liquid microextraction (DLLME), “quick, easy, cheap, effective, rugged, and safe” dispersive solid-phase extraction (QuEChERS-dSPE), and enhanced matrix removal-lipid (EMR-Lipid) dSPE) were evaluated for matrix removal efficiency, recovery rate, and matrix effect. In this study, EMR-Lipid dSPE was shown to effectively remove complicated matrix contents in soft-gels, compared to DLLME and QuEChERS-dSPE. For the rapid screening of a wide range of adulterants, extracted common ion chromatogram (ECIC) and neutral loss scan (NLS) based on specific common MS/MS fragments were applied to randomly collected soft-gel-type dietary supplement samples using UHPLC-Q/TOF-MS. Both ECICs and NLSs enabled rapid and simple screening of multi-class adulterants and could be an alternative to the multiple reaction monitoring (MRM) method. The developed method was validated in terms of limit of detection (LOD), precision, accuracy, recovery, and matrix effects. The range of LODs was 0.1–16 ng/g. The overall precision values were within 0.09–14.65%. The accuracy ranged from 81.6% to 116.6%. The recoveries and matrix effects of 92 illegal adulterants ranged within 16.9–119.4% and 69.8–114.8%, respectively. The established method was successfully applied to screen and identify 92 illegal adulterants in soft-gels. This method can be a promising tool for the high-throughput screening of various adulterants in dietary supplements and could be used as a more environmentally friendly routine analytical method for screening dietary supplements illegally adulterated with multi-class drug substances. MDPI 2021-06-15 /pmc/articles/PMC8232078/ /pubmed/34203614 http://dx.doi.org/10.3390/ph14060570 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Beom Hee
Lee, Wonwoong
Kim, You Lee
Lee, Ji Hyun
Hong, Jongki
Efficient Matrix Cleanup of Soft-Gel-Type Dietary Supplements for Rapid Screening of 92 Illegal Adulterants Using EMR-Lipid dSPE and UHPLC-Q/TOF-MS
title Efficient Matrix Cleanup of Soft-Gel-Type Dietary Supplements for Rapid Screening of 92 Illegal Adulterants Using EMR-Lipid dSPE and UHPLC-Q/TOF-MS
title_full Efficient Matrix Cleanup of Soft-Gel-Type Dietary Supplements for Rapid Screening of 92 Illegal Adulterants Using EMR-Lipid dSPE and UHPLC-Q/TOF-MS
title_fullStr Efficient Matrix Cleanup of Soft-Gel-Type Dietary Supplements for Rapid Screening of 92 Illegal Adulterants Using EMR-Lipid dSPE and UHPLC-Q/TOF-MS
title_full_unstemmed Efficient Matrix Cleanup of Soft-Gel-Type Dietary Supplements for Rapid Screening of 92 Illegal Adulterants Using EMR-Lipid dSPE and UHPLC-Q/TOF-MS
title_short Efficient Matrix Cleanup of Soft-Gel-Type Dietary Supplements for Rapid Screening of 92 Illegal Adulterants Using EMR-Lipid dSPE and UHPLC-Q/TOF-MS
title_sort efficient matrix cleanup of soft-gel-type dietary supplements for rapid screening of 92 illegal adulterants using emr-lipid dspe and uhplc-q/tof-ms
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8232078/
https://www.ncbi.nlm.nih.gov/pubmed/34203614
http://dx.doi.org/10.3390/ph14060570
work_keys_str_mv AT kimbeomhee efficientmatrixcleanupofsoftgeltypedietarysupplementsforrapidscreeningof92illegaladulterantsusingemrlipiddspeanduhplcqtofms
AT leewonwoong efficientmatrixcleanupofsoftgeltypedietarysupplementsforrapidscreeningof92illegaladulterantsusingemrlipiddspeanduhplcqtofms
AT kimyoulee efficientmatrixcleanupofsoftgeltypedietarysupplementsforrapidscreeningof92illegaladulterantsusingemrlipiddspeanduhplcqtofms
AT leejihyun efficientmatrixcleanupofsoftgeltypedietarysupplementsforrapidscreeningof92illegaladulterantsusingemrlipiddspeanduhplcqtofms
AT hongjongki efficientmatrixcleanupofsoftgeltypedietarysupplementsforrapidscreeningof92illegaladulterantsusingemrlipiddspeanduhplcqtofms