Cargando…

Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid

The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al(2)O(3)/water). A...

Descripción completa

Detalles Bibliográficos
Autores principales: Ju, Yongfeng, Zhu, Tiezhu, Mashayekhi, Ramin, Mohammed, Hayder I., Khan, Afrasyab, Talebizadehsardari, Pouyan, Yaïci, Wahiba
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8232209/
https://www.ncbi.nlm.nih.gov/pubmed/34203635
http://dx.doi.org/10.3390/nano11061570
_version_ 1783713587974373376
author Ju, Yongfeng
Zhu, Tiezhu
Mashayekhi, Ramin
Mohammed, Hayder I.
Khan, Afrasyab
Talebizadehsardari, Pouyan
Yaïci, Wahiba
author_facet Ju, Yongfeng
Zhu, Tiezhu
Mashayekhi, Ramin
Mohammed, Hayder I.
Khan, Afrasyab
Talebizadehsardari, Pouyan
Yaïci, Wahiba
author_sort Ju, Yongfeng
collection PubMed
description The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al(2)O(3)/water). A performance evaluation criterion (PEC) is defined to characterize the performance based on both friction factor and heat transfer. It was found that increasing the number of semi-twisted tapes increases the number of swirl flow streams and leads to an enhancement in the local Nusselt number as well as the friction factor. The average Nusselt number increases from 15.13 to 28.42 and the average friction factor enhances from 0.022 to 0.052 by increasing the number of the semi-twisted tapes from 0 to 4 for the Reynolds number of 1000 for the base fluid. By using four semi-twisted tapes, the average Nusselt number increases from 12.5 to 28.5, while the friction factor reduces from 0.155 to 0.052 when the Reynolds number increases from 250 to 1000 for the base fluid. For the Reynolds number of 1000, the increase in nanofluid concentration from 0 to 3% improves the average Nusselt number and friction factor by 6.41% and 2.29%, respectively. The highest PEC is equal to 1.66 and belongs to the Reynolds number of 750 using four semi-twisted tape inserts with 3% nanoparticles. This work offers instructions to model an advanced design of twisted tape integrated with tubes using multiple semi-twisted tapes, which helps to provide a higher amount of energy demand for solar applications.
format Online
Article
Text
id pubmed-8232209
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82322092021-06-26 Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid Ju, Yongfeng Zhu, Tiezhu Mashayekhi, Ramin Mohammed, Hayder I. Khan, Afrasyab Talebizadehsardari, Pouyan Yaïci, Wahiba Nanomaterials (Basel) Article The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al(2)O(3)/water). A performance evaluation criterion (PEC) is defined to characterize the performance based on both friction factor and heat transfer. It was found that increasing the number of semi-twisted tapes increases the number of swirl flow streams and leads to an enhancement in the local Nusselt number as well as the friction factor. The average Nusselt number increases from 15.13 to 28.42 and the average friction factor enhances from 0.022 to 0.052 by increasing the number of the semi-twisted tapes from 0 to 4 for the Reynolds number of 1000 for the base fluid. By using four semi-twisted tapes, the average Nusselt number increases from 12.5 to 28.5, while the friction factor reduces from 0.155 to 0.052 when the Reynolds number increases from 250 to 1000 for the base fluid. For the Reynolds number of 1000, the increase in nanofluid concentration from 0 to 3% improves the average Nusselt number and friction factor by 6.41% and 2.29%, respectively. The highest PEC is equal to 1.66 and belongs to the Reynolds number of 750 using four semi-twisted tape inserts with 3% nanoparticles. This work offers instructions to model an advanced design of twisted tape integrated with tubes using multiple semi-twisted tapes, which helps to provide a higher amount of energy demand for solar applications. MDPI 2021-06-15 /pmc/articles/PMC8232209/ /pubmed/34203635 http://dx.doi.org/10.3390/nano11061570 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ju, Yongfeng
Zhu, Tiezhu
Mashayekhi, Ramin
Mohammed, Hayder I.
Khan, Afrasyab
Talebizadehsardari, Pouyan
Yaïci, Wahiba
Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid
title Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid
title_full Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid
title_fullStr Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid
title_full_unstemmed Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid
title_short Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid
title_sort evaluation of multiple semi-twisted tape inserts in a heat exchanger pipe using al(2)o(3) nanofluid
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8232209/
https://www.ncbi.nlm.nih.gov/pubmed/34203635
http://dx.doi.org/10.3390/nano11061570
work_keys_str_mv AT juyongfeng evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid
AT zhutiezhu evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid
AT mashayekhiramin evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid
AT mohammedhayderi evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid
AT khanafrasyab evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid
AT talebizadehsardaripouyan evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid
AT yaiciwahiba evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid