Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid
The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al(2)O(3)/water). A...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8232209/ https://www.ncbi.nlm.nih.gov/pubmed/34203635 http://dx.doi.org/10.3390/nano11061570 |
_version_ | 1783713587974373376 |
---|---|
author | Ju, Yongfeng Zhu, Tiezhu Mashayekhi, Ramin Mohammed, Hayder I. Khan, Afrasyab Talebizadehsardari, Pouyan Yaïci, Wahiba |
author_facet | Ju, Yongfeng Zhu, Tiezhu Mashayekhi, Ramin Mohammed, Hayder I. Khan, Afrasyab Talebizadehsardari, Pouyan Yaïci, Wahiba |
author_sort | Ju, Yongfeng |
collection | PubMed |
description | The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al(2)O(3)/water). A performance evaluation criterion (PEC) is defined to characterize the performance based on both friction factor and heat transfer. It was found that increasing the number of semi-twisted tapes increases the number of swirl flow streams and leads to an enhancement in the local Nusselt number as well as the friction factor. The average Nusselt number increases from 15.13 to 28.42 and the average friction factor enhances from 0.022 to 0.052 by increasing the number of the semi-twisted tapes from 0 to 4 for the Reynolds number of 1000 for the base fluid. By using four semi-twisted tapes, the average Nusselt number increases from 12.5 to 28.5, while the friction factor reduces from 0.155 to 0.052 when the Reynolds number increases from 250 to 1000 for the base fluid. For the Reynolds number of 1000, the increase in nanofluid concentration from 0 to 3% improves the average Nusselt number and friction factor by 6.41% and 2.29%, respectively. The highest PEC is equal to 1.66 and belongs to the Reynolds number of 750 using four semi-twisted tape inserts with 3% nanoparticles. This work offers instructions to model an advanced design of twisted tape integrated with tubes using multiple semi-twisted tapes, which helps to provide a higher amount of energy demand for solar applications. |
format | Online Article Text |
id | pubmed-8232209 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82322092021-06-26 Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid Ju, Yongfeng Zhu, Tiezhu Mashayekhi, Ramin Mohammed, Hayder I. Khan, Afrasyab Talebizadehsardari, Pouyan Yaïci, Wahiba Nanomaterials (Basel) Article The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al(2)O(3)/water). A performance evaluation criterion (PEC) is defined to characterize the performance based on both friction factor and heat transfer. It was found that increasing the number of semi-twisted tapes increases the number of swirl flow streams and leads to an enhancement in the local Nusselt number as well as the friction factor. The average Nusselt number increases from 15.13 to 28.42 and the average friction factor enhances from 0.022 to 0.052 by increasing the number of the semi-twisted tapes from 0 to 4 for the Reynolds number of 1000 for the base fluid. By using four semi-twisted tapes, the average Nusselt number increases from 12.5 to 28.5, while the friction factor reduces from 0.155 to 0.052 when the Reynolds number increases from 250 to 1000 for the base fluid. For the Reynolds number of 1000, the increase in nanofluid concentration from 0 to 3% improves the average Nusselt number and friction factor by 6.41% and 2.29%, respectively. The highest PEC is equal to 1.66 and belongs to the Reynolds number of 750 using four semi-twisted tape inserts with 3% nanoparticles. This work offers instructions to model an advanced design of twisted tape integrated with tubes using multiple semi-twisted tapes, which helps to provide a higher amount of energy demand for solar applications. MDPI 2021-06-15 /pmc/articles/PMC8232209/ /pubmed/34203635 http://dx.doi.org/10.3390/nano11061570 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ju, Yongfeng Zhu, Tiezhu Mashayekhi, Ramin Mohammed, Hayder I. Khan, Afrasyab Talebizadehsardari, Pouyan Yaïci, Wahiba Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid |
title | Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid |
title_full | Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid |
title_fullStr | Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid |
title_full_unstemmed | Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid |
title_short | Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al(2)O(3) Nanofluid |
title_sort | evaluation of multiple semi-twisted tape inserts in a heat exchanger pipe using al(2)o(3) nanofluid |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8232209/ https://www.ncbi.nlm.nih.gov/pubmed/34203635 http://dx.doi.org/10.3390/nano11061570 |
work_keys_str_mv | AT juyongfeng evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid AT zhutiezhu evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid AT mashayekhiramin evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid AT mohammedhayderi evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid AT khanafrasyab evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid AT talebizadehsardaripouyan evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid AT yaiciwahiba evaluationofmultiplesemitwistedtapeinsertsinaheatexchangerpipeusingal2o3nanofluid |