Trends in the Design of Intensity-Based Optical Fiber Biosensors (2010–2020)
There exists an increasing interest in monitoring low concentrations of biochemical species, as they allow the early-stage detection of illnesses or the monitoring of the environment quality. Thus, both companies and research groups are focused on the development of accurate, fast and highly sensiti...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8232210/ https://www.ncbi.nlm.nih.gov/pubmed/34203715 http://dx.doi.org/10.3390/bios11060197 |
_version_ | 1783713588204011520 |
---|---|
author | De Acha, Nerea Socorro-Leránoz, Abián B. Elosúa, César Matías, Ignacio R. |
author_facet | De Acha, Nerea Socorro-Leránoz, Abián B. Elosúa, César Matías, Ignacio R. |
author_sort | De Acha, Nerea |
collection | PubMed |
description | There exists an increasing interest in monitoring low concentrations of biochemical species, as they allow the early-stage detection of illnesses or the monitoring of the environment quality. Thus, both companies and research groups are focused on the development of accurate, fast and highly sensitive biosensors. Optical fiber sensors have been widely employed for these purposes because they provide several advantages for their use in point-of-care and real-time applications. In particular, this review is focused on optical fiber biosensors based on luminescence and absorption. Apart from the key parameters that determine the performance of a sensor (limit of detection, sensibility, cross-sensibility, etc.), other features are analyzed, such as the optical fiber dimensions, the sensing set ups and the fiber functionalization. The aim of this review is to have a comprehensive insight of the different aspects that must be taken into account when working with this kind of sensors. |
format | Online Article Text |
id | pubmed-8232210 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82322102021-06-26 Trends in the Design of Intensity-Based Optical Fiber Biosensors (2010–2020) De Acha, Nerea Socorro-Leránoz, Abián B. Elosúa, César Matías, Ignacio R. Biosensors (Basel) Review There exists an increasing interest in monitoring low concentrations of biochemical species, as they allow the early-stage detection of illnesses or the monitoring of the environment quality. Thus, both companies and research groups are focused on the development of accurate, fast and highly sensitive biosensors. Optical fiber sensors have been widely employed for these purposes because they provide several advantages for their use in point-of-care and real-time applications. In particular, this review is focused on optical fiber biosensors based on luminescence and absorption. Apart from the key parameters that determine the performance of a sensor (limit of detection, sensibility, cross-sensibility, etc.), other features are analyzed, such as the optical fiber dimensions, the sensing set ups and the fiber functionalization. The aim of this review is to have a comprehensive insight of the different aspects that must be taken into account when working with this kind of sensors. MDPI 2021-06-15 /pmc/articles/PMC8232210/ /pubmed/34203715 http://dx.doi.org/10.3390/bios11060197 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review De Acha, Nerea Socorro-Leránoz, Abián B. Elosúa, César Matías, Ignacio R. Trends in the Design of Intensity-Based Optical Fiber Biosensors (2010–2020) |
title | Trends in the Design of Intensity-Based Optical Fiber Biosensors (2010–2020) |
title_full | Trends in the Design of Intensity-Based Optical Fiber Biosensors (2010–2020) |
title_fullStr | Trends in the Design of Intensity-Based Optical Fiber Biosensors (2010–2020) |
title_full_unstemmed | Trends in the Design of Intensity-Based Optical Fiber Biosensors (2010–2020) |
title_short | Trends in the Design of Intensity-Based Optical Fiber Biosensors (2010–2020) |
title_sort | trends in the design of intensity-based optical fiber biosensors (2010–2020) |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8232210/ https://www.ncbi.nlm.nih.gov/pubmed/34203715 http://dx.doi.org/10.3390/bios11060197 |
work_keys_str_mv | AT deachanerea trendsinthedesignofintensitybasedopticalfiberbiosensors20102020 AT socorroleranozabianb trendsinthedesignofintensitybasedopticalfiberbiosensors20102020 AT elosuacesar trendsinthedesignofintensitybasedopticalfiberbiosensors20102020 AT matiasignacior trendsinthedesignofintensitybasedopticalfiberbiosensors20102020 |