Cargando…

Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor

A biosensing membrane base on ferulic acid and glucose oxidase is synthesized onto a carbon paste electrode by electropolymerization via cyclic voltammetry in aqueous media at neutral pH at a single step. The developed biosensors exhibit a linear response from 0.082 to 34 mM glucose concentration, w...

Descripción completa

Detalles Bibliográficos
Autores principales: Valdés-Ramírez, Gabriela, Galicia, Laura
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8233774/
https://www.ncbi.nlm.nih.gov/pubmed/34203057
http://dx.doi.org/10.3390/molecules26123757
_version_ 1783713927429881856
author Valdés-Ramírez, Gabriela
Galicia, Laura
author_facet Valdés-Ramírez, Gabriela
Galicia, Laura
author_sort Valdés-Ramírez, Gabriela
collection PubMed
description A biosensing membrane base on ferulic acid and glucose oxidase is synthesized onto a carbon paste electrode by electropolymerization via cyclic voltammetry in aqueous media at neutral pH at a single step. The developed biosensors exhibit a linear response from 0.082 to 34 mM glucose concentration, with a coefficient of determination R(2) equal to 0.997. The biosensors display a sensitivity of 1.1 μAmM(−1) cm(−2), a detection limit of 0.025 mM, and 0.082 mM as glucose quantification limit. The studies reveal stable, repeatable, and reproducible biosensors response. The results indicate that the novel poly-ferulic acid membrane synthesized by electropolymerization is a promising method for glucose oxidase immobilization towards the development of glucose biosensors. The developed glucose biosensors exhibit a broader linear glucose response than other polymer-based glucose biosensors.
format Online
Article
Text
id pubmed-8233774
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82337742021-06-27 Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor Valdés-Ramírez, Gabriela Galicia, Laura Molecules Communication A biosensing membrane base on ferulic acid and glucose oxidase is synthesized onto a carbon paste electrode by electropolymerization via cyclic voltammetry in aqueous media at neutral pH at a single step. The developed biosensors exhibit a linear response from 0.082 to 34 mM glucose concentration, with a coefficient of determination R(2) equal to 0.997. The biosensors display a sensitivity of 1.1 μAmM(−1) cm(−2), a detection limit of 0.025 mM, and 0.082 mM as glucose quantification limit. The studies reveal stable, repeatable, and reproducible biosensors response. The results indicate that the novel poly-ferulic acid membrane synthesized by electropolymerization is a promising method for glucose oxidase immobilization towards the development of glucose biosensors. The developed glucose biosensors exhibit a broader linear glucose response than other polymer-based glucose biosensors. MDPI 2021-06-20 /pmc/articles/PMC8233774/ /pubmed/34203057 http://dx.doi.org/10.3390/molecules26123757 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Valdés-Ramírez, Gabriela
Galicia, Laura
Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor
title Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor
title_full Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor
title_fullStr Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor
title_full_unstemmed Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor
title_short Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor
title_sort biosensing membrane base on ferulic acid and glucose oxidase for an amperometric glucose biosensor
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8233774/
https://www.ncbi.nlm.nih.gov/pubmed/34203057
http://dx.doi.org/10.3390/molecules26123757
work_keys_str_mv AT valdesramirezgabriela biosensingmembranebaseonferulicacidandglucoseoxidaseforanamperometricglucosebiosensor
AT galicialaura biosensingmembranebaseonferulicacidandglucoseoxidaseforanamperometricglucosebiosensor