A biosensing membrane base on ferulic acid and glucose oxidase is synthesized onto a carbon paste electrode by electropolymerization via cyclic voltammetry in aqueous media at neutral pH at a single step. The developed biosensors exhibit a linear response from 0.082 to 34 mM glucose concentration, w...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8233774/ https://www.ncbi.nlm.nih.gov/pubmed/34203057 http://dx.doi.org/10.3390/molecules26123757 |
_version_ | 1783713927429881856 |
---|---|
author | Valdés-Ramírez, Gabriela Galicia, Laura |
author_facet | Valdés-Ramírez, Gabriela Galicia, Laura |
author_sort | Valdés-Ramírez, Gabriela |
collection | PubMed |
description | A biosensing membrane base on ferulic acid and glucose oxidase is synthesized onto a carbon paste electrode by electropolymerization via cyclic voltammetry in aqueous media at neutral pH at a single step. The developed biosensors exhibit a linear response from 0.082 to 34 mM glucose concentration, with a coefficient of determination R(2) equal to 0.997. The biosensors display a sensitivity of 1.1 μAmM(−1) cm(−2), a detection limit of 0.025 mM, and 0.082 mM as glucose quantification limit. The studies reveal stable, repeatable, and reproducible biosensors response. The results indicate that the novel poly-ferulic acid membrane synthesized by electropolymerization is a promising method for glucose oxidase immobilization towards the development of glucose biosensors. The developed glucose biosensors exhibit a broader linear glucose response than other polymer-based glucose biosensors. |
format | Online Article Text |
id | pubmed-8233774 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82337742021-06-27 Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor Valdés-Ramírez, Gabriela Galicia, Laura Molecules Communication A biosensing membrane base on ferulic acid and glucose oxidase is synthesized onto a carbon paste electrode by electropolymerization via cyclic voltammetry in aqueous media at neutral pH at a single step. The developed biosensors exhibit a linear response from 0.082 to 34 mM glucose concentration, with a coefficient of determination R(2) equal to 0.997. The biosensors display a sensitivity of 1.1 μAmM(−1) cm(−2), a detection limit of 0.025 mM, and 0.082 mM as glucose quantification limit. The studies reveal stable, repeatable, and reproducible biosensors response. The results indicate that the novel poly-ferulic acid membrane synthesized by electropolymerization is a promising method for glucose oxidase immobilization towards the development of glucose biosensors. The developed glucose biosensors exhibit a broader linear glucose response than other polymer-based glucose biosensors. MDPI 2021-06-20 /pmc/articles/PMC8233774/ /pubmed/34203057 http://dx.doi.org/10.3390/molecules26123757 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Valdés-Ramírez, Gabriela Galicia, Laura Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor |
title | Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor |
title_full | Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor |
title_fullStr | Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor |
title_full_unstemmed | Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor |
title_short | Biosensing Membrane Base on Ferulic Acid and Glucose Oxidase for an Amperometric Glucose Biosensor |
title_sort | biosensing membrane base on ferulic acid and glucose oxidase for an amperometric glucose biosensor |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8233774/ https://www.ncbi.nlm.nih.gov/pubmed/34203057 http://dx.doi.org/10.3390/molecules26123757 |
work_keys_str_mv | AT valdesramirezgabriela biosensingmembranebaseonferulicacidandglucoseoxidaseforanamperometricglucosebiosensor AT galicialaura biosensingmembranebaseonferulicacidandglucoseoxidaseforanamperometricglucosebiosensor |