Cargando…
Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies
Computer-assisted analysis is expected to improve the reliability of videofluoroscopic swallowing studies (VFSSs), but its usefulness is limited. Previously, we proposed a deep learning model that can detect laryngeal penetration or aspiration fully automatically in VFSS video images, but the eviden...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8233836/ https://www.ncbi.nlm.nih.gov/pubmed/34207049 http://dx.doi.org/10.3390/jcm10122681 |
_version_ | 1783713942242066432 |
---|---|
author | Kim, Yuna Kim, Hyun-Il Park, Geun Seok Kim, Seo Young Choi, Sang-Il Lee, Seong Jae |
author_facet | Kim, Yuna Kim, Hyun-Il Park, Geun Seok Kim, Seo Young Choi, Sang-Il Lee, Seong Jae |
author_sort | Kim, Yuna |
collection | PubMed |
description | Computer-assisted analysis is expected to improve the reliability of videofluoroscopic swallowing studies (VFSSs), but its usefulness is limited. Previously, we proposed a deep learning model that can detect laryngeal penetration or aspiration fully automatically in VFSS video images, but the evidence for its reliability was insufficient. This study aims to compare the intra- and inter-rater reliability of the computer model and human raters. The test dataset consisted of 173 video files from which the existence of laryngeal penetration or aspiration was judged by the computer and three physicians in two sessions separated by a one-month interval. Intra- and inter-rater reliability were calculated using Cohen’s kappa coefficient, the positive reliability ratio (PRR) and the negative reliability ratio (NRR). Intrarater reliability was almost perfect for the computer and two experienced physicians. Interrater reliability was moderate to substantial between the model and each human rater and between the human raters. The average PRR and NRR between the model and the human raters were similar to those between the human raters. The results demonstrate that the deep learning model can detect laryngeal penetration or aspiration from VFSS video as reliably as human examiners. |
format | Online Article Text |
id | pubmed-8233836 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82338362021-06-27 Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies Kim, Yuna Kim, Hyun-Il Park, Geun Seok Kim, Seo Young Choi, Sang-Il Lee, Seong Jae J Clin Med Article Computer-assisted analysis is expected to improve the reliability of videofluoroscopic swallowing studies (VFSSs), but its usefulness is limited. Previously, we proposed a deep learning model that can detect laryngeal penetration or aspiration fully automatically in VFSS video images, but the evidence for its reliability was insufficient. This study aims to compare the intra- and inter-rater reliability of the computer model and human raters. The test dataset consisted of 173 video files from which the existence of laryngeal penetration or aspiration was judged by the computer and three physicians in two sessions separated by a one-month interval. Intra- and inter-rater reliability were calculated using Cohen’s kappa coefficient, the positive reliability ratio (PRR) and the negative reliability ratio (NRR). Intrarater reliability was almost perfect for the computer and two experienced physicians. Interrater reliability was moderate to substantial between the model and each human rater and between the human raters. The average PRR and NRR between the model and the human raters were similar to those between the human raters. The results demonstrate that the deep learning model can detect laryngeal penetration or aspiration from VFSS video as reliably as human examiners. MDPI 2021-06-18 /pmc/articles/PMC8233836/ /pubmed/34207049 http://dx.doi.org/10.3390/jcm10122681 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kim, Yuna Kim, Hyun-Il Park, Geun Seok Kim, Seo Young Choi, Sang-Il Lee, Seong Jae Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies |
title | Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies |
title_full | Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies |
title_fullStr | Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies |
title_full_unstemmed | Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies |
title_short | Reliability of Machine and Human Examiners for Detection of Laryngeal Penetration or Aspiration in Videofluoroscopic Swallowing Studies |
title_sort | reliability of machine and human examiners for detection of laryngeal penetration or aspiration in videofluoroscopic swallowing studies |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8233836/ https://www.ncbi.nlm.nih.gov/pubmed/34207049 http://dx.doi.org/10.3390/jcm10122681 |
work_keys_str_mv | AT kimyuna reliabilityofmachineandhumanexaminersfordetectionoflaryngealpenetrationoraspirationinvideofluoroscopicswallowingstudies AT kimhyunil reliabilityofmachineandhumanexaminersfordetectionoflaryngealpenetrationoraspirationinvideofluoroscopicswallowingstudies AT parkgeunseok reliabilityofmachineandhumanexaminersfordetectionoflaryngealpenetrationoraspirationinvideofluoroscopicswallowingstudies AT kimseoyoung reliabilityofmachineandhumanexaminersfordetectionoflaryngealpenetrationoraspirationinvideofluoroscopicswallowingstudies AT choisangil reliabilityofmachineandhumanexaminersfordetectionoflaryngealpenetrationoraspirationinvideofluoroscopicswallowingstudies AT leeseongjae reliabilityofmachineandhumanexaminersfordetectionoflaryngealpenetrationoraspirationinvideofluoroscopicswallowingstudies |