Cargando…

The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation

The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient’s anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intrao...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferretti, Andrea, Iannotti, Ferdinando, Proietti, Lorenzo, Massafra, Carlo, Speranza, Attilio, Laghi, Andrea, Iorio, Raffaele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8234047/
https://www.ncbi.nlm.nih.gov/pubmed/34203107
http://dx.doi.org/10.3390/s21124232
_version_ 1783713992230830080
author Ferretti, Andrea
Iannotti, Ferdinando
Proietti, Lorenzo
Massafra, Carlo
Speranza, Attilio
Laghi, Andrea
Iorio, Raffaele
author_facet Ferretti, Andrea
Iannotti, Ferdinando
Proietti, Lorenzo
Massafra, Carlo
Speranza, Attilio
Laghi, Andrea
Iorio, Raffaele
author_sort Ferretti, Andrea
collection PubMed
description The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient’s anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intraoperatively. The main purpose of this study was to verify the reliability and accuracy of a patient-specific instrumentation (PSI) and laser-guided technique to replicate preoperative dynamic planning. Thirty-six patients were prospectively enrolled and received dynamic hip preoperative planning based on three functional lateral spinopelvic X-rays and a low dose CT scan. Three-dimensional (3D) printed PSI guides and laser-guided instrumentation were used intraoperatively. The orientation of the components, osteotomy level and change in hip length and offset were measured on postoperative CT scans and compared with the planned preoperative values. The length of surgery was compared with that of a matched group of thirty-six patients who underwent a conventional THA. The mean absolute deviation from the planned inclination and anteversion was 3.9° and 4.4°, respectively. In 92% of cases, both the inclination and anteversion were within +/− 10° of the planned values. Regarding the osteotomy level, offset change and limb length change, the mean deviation was, respectively, 1.6 mm, 2.6 mm and 2 mm. No statistically significant difference was detected when comparing the planned values with the achieved values. The mean surgical time was 71.4 min in the PSI group and 60.4 min in the conventional THA group (p < 0.05). Patient-specific and laser-guided instrumentation is safe and accurately reproduces dynamic planning in terms of the orientation of the components, osteotomy level, leg length and offset. Moreover, the increase in surgical time is negligible.
format Online
Article
Text
id pubmed-8234047
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82340472021-06-27 The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation Ferretti, Andrea Iannotti, Ferdinando Proietti, Lorenzo Massafra, Carlo Speranza, Attilio Laghi, Andrea Iorio, Raffaele Sensors (Basel) Article The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient’s anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intraoperatively. The main purpose of this study was to verify the reliability and accuracy of a patient-specific instrumentation (PSI) and laser-guided technique to replicate preoperative dynamic planning. Thirty-six patients were prospectively enrolled and received dynamic hip preoperative planning based on three functional lateral spinopelvic X-rays and a low dose CT scan. Three-dimensional (3D) printed PSI guides and laser-guided instrumentation were used intraoperatively. The orientation of the components, osteotomy level and change in hip length and offset were measured on postoperative CT scans and compared with the planned preoperative values. The length of surgery was compared with that of a matched group of thirty-six patients who underwent a conventional THA. The mean absolute deviation from the planned inclination and anteversion was 3.9° and 4.4°, respectively. In 92% of cases, both the inclination and anteversion were within +/− 10° of the planned values. Regarding the osteotomy level, offset change and limb length change, the mean deviation was, respectively, 1.6 mm, 2.6 mm and 2 mm. No statistically significant difference was detected when comparing the planned values with the achieved values. The mean surgical time was 71.4 min in the PSI group and 60.4 min in the conventional THA group (p < 0.05). Patient-specific and laser-guided instrumentation is safe and accurately reproduces dynamic planning in terms of the orientation of the components, osteotomy level, leg length and offset. Moreover, the increase in surgical time is negligible. MDPI 2021-06-20 /pmc/articles/PMC8234047/ /pubmed/34203107 http://dx.doi.org/10.3390/s21124232 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ferretti, Andrea
Iannotti, Ferdinando
Proietti, Lorenzo
Massafra, Carlo
Speranza, Attilio
Laghi, Andrea
Iorio, Raffaele
The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation
title The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation
title_full The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation
title_fullStr The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation
title_full_unstemmed The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation
title_short The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation
title_sort accuracy of patient-specific instrumentation with laser guidance in a dynamic total hip arthroplasty: a radiological evaluation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8234047/
https://www.ncbi.nlm.nih.gov/pubmed/34203107
http://dx.doi.org/10.3390/s21124232
work_keys_str_mv AT ferrettiandrea theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT iannottiferdinando theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT proiettilorenzo theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT massafracarlo theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT speranzaattilio theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT laghiandrea theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT iorioraffaele theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT ferrettiandrea accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT iannottiferdinando accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT proiettilorenzo accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT massafracarlo accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT speranzaattilio accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT laghiandrea accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation
AT iorioraffaele accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation