Cargando…
The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation
The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient’s anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intrao...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8234047/ https://www.ncbi.nlm.nih.gov/pubmed/34203107 http://dx.doi.org/10.3390/s21124232 |
_version_ | 1783713992230830080 |
---|---|
author | Ferretti, Andrea Iannotti, Ferdinando Proietti, Lorenzo Massafra, Carlo Speranza, Attilio Laghi, Andrea Iorio, Raffaele |
author_facet | Ferretti, Andrea Iannotti, Ferdinando Proietti, Lorenzo Massafra, Carlo Speranza, Attilio Laghi, Andrea Iorio, Raffaele |
author_sort | Ferretti, Andrea |
collection | PubMed |
description | The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient’s anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intraoperatively. The main purpose of this study was to verify the reliability and accuracy of a patient-specific instrumentation (PSI) and laser-guided technique to replicate preoperative dynamic planning. Thirty-six patients were prospectively enrolled and received dynamic hip preoperative planning based on three functional lateral spinopelvic X-rays and a low dose CT scan. Three-dimensional (3D) printed PSI guides and laser-guided instrumentation were used intraoperatively. The orientation of the components, osteotomy level and change in hip length and offset were measured on postoperative CT scans and compared with the planned preoperative values. The length of surgery was compared with that of a matched group of thirty-six patients who underwent a conventional THA. The mean absolute deviation from the planned inclination and anteversion was 3.9° and 4.4°, respectively. In 92% of cases, both the inclination and anteversion were within +/− 10° of the planned values. Regarding the osteotomy level, offset change and limb length change, the mean deviation was, respectively, 1.6 mm, 2.6 mm and 2 mm. No statistically significant difference was detected when comparing the planned values with the achieved values. The mean surgical time was 71.4 min in the PSI group and 60.4 min in the conventional THA group (p < 0.05). Patient-specific and laser-guided instrumentation is safe and accurately reproduces dynamic planning in terms of the orientation of the components, osteotomy level, leg length and offset. Moreover, the increase in surgical time is negligible. |
format | Online Article Text |
id | pubmed-8234047 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82340472021-06-27 The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation Ferretti, Andrea Iannotti, Ferdinando Proietti, Lorenzo Massafra, Carlo Speranza, Attilio Laghi, Andrea Iorio, Raffaele Sensors (Basel) Article The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient’s anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intraoperatively. The main purpose of this study was to verify the reliability and accuracy of a patient-specific instrumentation (PSI) and laser-guided technique to replicate preoperative dynamic planning. Thirty-six patients were prospectively enrolled and received dynamic hip preoperative planning based on three functional lateral spinopelvic X-rays and a low dose CT scan. Three-dimensional (3D) printed PSI guides and laser-guided instrumentation were used intraoperatively. The orientation of the components, osteotomy level and change in hip length and offset were measured on postoperative CT scans and compared with the planned preoperative values. The length of surgery was compared with that of a matched group of thirty-six patients who underwent a conventional THA. The mean absolute deviation from the planned inclination and anteversion was 3.9° and 4.4°, respectively. In 92% of cases, both the inclination and anteversion were within +/− 10° of the planned values. Regarding the osteotomy level, offset change and limb length change, the mean deviation was, respectively, 1.6 mm, 2.6 mm and 2 mm. No statistically significant difference was detected when comparing the planned values with the achieved values. The mean surgical time was 71.4 min in the PSI group and 60.4 min in the conventional THA group (p < 0.05). Patient-specific and laser-guided instrumentation is safe and accurately reproduces dynamic planning in terms of the orientation of the components, osteotomy level, leg length and offset. Moreover, the increase in surgical time is negligible. MDPI 2021-06-20 /pmc/articles/PMC8234047/ /pubmed/34203107 http://dx.doi.org/10.3390/s21124232 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ferretti, Andrea Iannotti, Ferdinando Proietti, Lorenzo Massafra, Carlo Speranza, Attilio Laghi, Andrea Iorio, Raffaele The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation |
title | The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation |
title_full | The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation |
title_fullStr | The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation |
title_full_unstemmed | The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation |
title_short | The Accuracy of Patient-Specific Instrumentation with Laser Guidance in a Dynamic Total Hip Arthroplasty: A Radiological Evaluation |
title_sort | accuracy of patient-specific instrumentation with laser guidance in a dynamic total hip arthroplasty: a radiological evaluation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8234047/ https://www.ncbi.nlm.nih.gov/pubmed/34203107 http://dx.doi.org/10.3390/s21124232 |
work_keys_str_mv | AT ferrettiandrea theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT iannottiferdinando theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT proiettilorenzo theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT massafracarlo theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT speranzaattilio theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT laghiandrea theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT iorioraffaele theaccuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT ferrettiandrea accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT iannottiferdinando accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT proiettilorenzo accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT massafracarlo accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT speranzaattilio accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT laghiandrea accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation AT iorioraffaele accuracyofpatientspecificinstrumentationwithlaserguidanceinadynamictotalhiparthroplastyaradiologicalevaluation |