Cargando…

A Multifunctional Smart Meter Using ANN-PSO Flux Estimation and Harmonic Active Compensation with Fuzzy Voltage Regulation

This paper aims to present the analysis and development of a complete electronic smart meter that is able to perform four-quadrant measurements, act as a three-phase shunt active power filter (APF), and control three-phase induction motors by stator flux estimation. A transmission control protocol t...

Descripción completa

Detalles Bibliográficos
Autores principales: Batista, Edson A., de Brito, Moacyr A. G., Siqueira, João C., Dias, Jeandro C., Gomez, Raphael C., Catharino, Maurilio F. R., Gomes, Matheus B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8234700/
https://www.ncbi.nlm.nih.gov/pubmed/34204334
http://dx.doi.org/10.3390/s21124154
_version_ 1783714144863649792
author Batista, Edson A.
de Brito, Moacyr A. G.
Siqueira, João C.
Dias, Jeandro C.
Gomez, Raphael C.
Catharino, Maurilio F. R.
Gomes, Matheus B.
author_facet Batista, Edson A.
de Brito, Moacyr A. G.
Siqueira, João C.
Dias, Jeandro C.
Gomez, Raphael C.
Catharino, Maurilio F. R.
Gomes, Matheus B.
author_sort Batista, Edson A.
collection PubMed
description This paper aims to present the analysis and development of a complete electronic smart meter that is able to perform four-quadrant measurements, act as a three-phase shunt active power filter (APF), and control three-phase induction motors by stator flux estimation. A transmission control protocol together with Internet protocol (TCP/IP) communication protocol for the remote access of measurement data is embedded into the application to securely transmit reliable information. An artificial neural network trained with particle swarm optimization is used for stator flux estimation, and a fuzzy logic controller is adopted to regulate the power converter DC bus voltage. The present work gathers knowledge from multidisciplinary fields, and all applied techniques have not been proposed altogether before. All control functions are embedded into a field-programmable gate array (FPGA) device, using VHSIC Hardware Description Language (VHDL), to enhance efficiency taking advantage of parallelism and high speed. An FPGA-in-the-loop cosimulation technique was first applied to prove the control functions’ functionality, and, later, experimental evaluations are conducted to finally prove equipment operation and reliability.
format Online
Article
Text
id pubmed-8234700
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82347002021-06-27 A Multifunctional Smart Meter Using ANN-PSO Flux Estimation and Harmonic Active Compensation with Fuzzy Voltage Regulation Batista, Edson A. de Brito, Moacyr A. G. Siqueira, João C. Dias, Jeandro C. Gomez, Raphael C. Catharino, Maurilio F. R. Gomes, Matheus B. Sensors (Basel) Article This paper aims to present the analysis and development of a complete electronic smart meter that is able to perform four-quadrant measurements, act as a three-phase shunt active power filter (APF), and control three-phase induction motors by stator flux estimation. A transmission control protocol together with Internet protocol (TCP/IP) communication protocol for the remote access of measurement data is embedded into the application to securely transmit reliable information. An artificial neural network trained with particle swarm optimization is used for stator flux estimation, and a fuzzy logic controller is adopted to regulate the power converter DC bus voltage. The present work gathers knowledge from multidisciplinary fields, and all applied techniques have not been proposed altogether before. All control functions are embedded into a field-programmable gate array (FPGA) device, using VHSIC Hardware Description Language (VHDL), to enhance efficiency taking advantage of parallelism and high speed. An FPGA-in-the-loop cosimulation technique was first applied to prove the control functions’ functionality, and, later, experimental evaluations are conducted to finally prove equipment operation and reliability. MDPI 2021-06-17 /pmc/articles/PMC8234700/ /pubmed/34204334 http://dx.doi.org/10.3390/s21124154 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Batista, Edson A.
de Brito, Moacyr A. G.
Siqueira, João C.
Dias, Jeandro C.
Gomez, Raphael C.
Catharino, Maurilio F. R.
Gomes, Matheus B.
A Multifunctional Smart Meter Using ANN-PSO Flux Estimation and Harmonic Active Compensation with Fuzzy Voltage Regulation
title A Multifunctional Smart Meter Using ANN-PSO Flux Estimation and Harmonic Active Compensation with Fuzzy Voltage Regulation
title_full A Multifunctional Smart Meter Using ANN-PSO Flux Estimation and Harmonic Active Compensation with Fuzzy Voltage Regulation
title_fullStr A Multifunctional Smart Meter Using ANN-PSO Flux Estimation and Harmonic Active Compensation with Fuzzy Voltage Regulation
title_full_unstemmed A Multifunctional Smart Meter Using ANN-PSO Flux Estimation and Harmonic Active Compensation with Fuzzy Voltage Regulation
title_short A Multifunctional Smart Meter Using ANN-PSO Flux Estimation and Harmonic Active Compensation with Fuzzy Voltage Regulation
title_sort multifunctional smart meter using ann-pso flux estimation and harmonic active compensation with fuzzy voltage regulation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8234700/
https://www.ncbi.nlm.nih.gov/pubmed/34204334
http://dx.doi.org/10.3390/s21124154
work_keys_str_mv AT batistaedsona amultifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT debritomoacyrag amultifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT siqueirajoaoc amultifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT diasjeandroc amultifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT gomezraphaelc amultifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT catharinomauriliofr amultifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT gomesmatheusb amultifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT batistaedsona multifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT debritomoacyrag multifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT siqueirajoaoc multifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT diasjeandroc multifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT gomezraphaelc multifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT catharinomauriliofr multifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation
AT gomesmatheusb multifunctionalsmartmeterusingannpsofluxestimationandharmonicactivecompensationwithfuzzyvoltageregulation