Electrical Resistivity of Steel Fibre-Reinforced Concrete—Influencing Parameters
This paper presents a systematic study of the electrical resistivity of different steel fibre-reinforced concretes with fibre contents from 0 kg/m(3) to 80 kg/m(3) in order to identify possible effects of interactions among concrete composition and fibre type and content regarding electrical resisti...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8235041/ https://www.ncbi.nlm.nih.gov/pubmed/34202943 http://dx.doi.org/10.3390/ma14123408 |
_version_ | 1783714223758508032 |
---|---|
author | Cleven, Simon Raupach, Michael Matschei, Thomas |
author_facet | Cleven, Simon Raupach, Michael Matschei, Thomas |
author_sort | Cleven, Simon |
collection | PubMed |
description | This paper presents a systematic study of the electrical resistivity of different steel fibre-reinforced concretes with fibre contents from 0 kg/m(3) to 80 kg/m(3) in order to identify possible effects of interactions among concrete composition and fibre type and content regarding electrical resistivity. Based on a literature review, four parameters, w/c ratio, binder content, ground granulated blast-furnace slag (GGBS) and fineness of cement, which show a significant influence on the electrical resistivity of plain concrete, were identified, and their influence on the electrical resistivity as well as interaction effects were investigated. The results of the experiments highlight that the addition of fibres leads to a significant decrease in electrical resistivity, independent of all additional parameters of the concrete composition. Additionally, it was shown that a higher porosity of the concrete, e.g., due to a higher w/c ratio, also results in a lower electrical resistivity. These results are in agreement with the literature review on plain concrete, while the influence of the concrete composition on the electrical resistivity is weaker with the increase in fibre content. The influence of fibre reinforcement is thus not affected by changes in the concrete composition. In general, a higher fibre dosage leads to a decrease in electrical resistivity, but the impact on the electrical resistivity varies slightly with different types of steel fibres. Based on this study, the potential of determining the fibre content using electrical resistivity measurements could be clearly presented. |
format | Online Article Text |
id | pubmed-8235041 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82350412021-06-27 Electrical Resistivity of Steel Fibre-Reinforced Concrete—Influencing Parameters Cleven, Simon Raupach, Michael Matschei, Thomas Materials (Basel) Article This paper presents a systematic study of the electrical resistivity of different steel fibre-reinforced concretes with fibre contents from 0 kg/m(3) to 80 kg/m(3) in order to identify possible effects of interactions among concrete composition and fibre type and content regarding electrical resistivity. Based on a literature review, four parameters, w/c ratio, binder content, ground granulated blast-furnace slag (GGBS) and fineness of cement, which show a significant influence on the electrical resistivity of plain concrete, were identified, and their influence on the electrical resistivity as well as interaction effects were investigated. The results of the experiments highlight that the addition of fibres leads to a significant decrease in electrical resistivity, independent of all additional parameters of the concrete composition. Additionally, it was shown that a higher porosity of the concrete, e.g., due to a higher w/c ratio, also results in a lower electrical resistivity. These results are in agreement with the literature review on plain concrete, while the influence of the concrete composition on the electrical resistivity is weaker with the increase in fibre content. The influence of fibre reinforcement is thus not affected by changes in the concrete composition. In general, a higher fibre dosage leads to a decrease in electrical resistivity, but the impact on the electrical resistivity varies slightly with different types of steel fibres. Based on this study, the potential of determining the fibre content using electrical resistivity measurements could be clearly presented. MDPI 2021-06-20 /pmc/articles/PMC8235041/ /pubmed/34202943 http://dx.doi.org/10.3390/ma14123408 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Cleven, Simon Raupach, Michael Matschei, Thomas Electrical Resistivity of Steel Fibre-Reinforced Concrete—Influencing Parameters |
title | Electrical Resistivity of Steel Fibre-Reinforced Concrete—Influencing Parameters |
title_full | Electrical Resistivity of Steel Fibre-Reinforced Concrete—Influencing Parameters |
title_fullStr | Electrical Resistivity of Steel Fibre-Reinforced Concrete—Influencing Parameters |
title_full_unstemmed | Electrical Resistivity of Steel Fibre-Reinforced Concrete—Influencing Parameters |
title_short | Electrical Resistivity of Steel Fibre-Reinforced Concrete—Influencing Parameters |
title_sort | electrical resistivity of steel fibre-reinforced concrete—influencing parameters |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8235041/ https://www.ncbi.nlm.nih.gov/pubmed/34202943 http://dx.doi.org/10.3390/ma14123408 |
work_keys_str_mv | AT clevensimon electricalresistivityofsteelfibrereinforcedconcreteinfluencingparameters AT raupachmichael electricalresistivityofsteelfibrereinforcedconcreteinfluencingparameters AT matscheithomas electricalresistivityofsteelfibrereinforcedconcreteinfluencingparameters |