Cargando…
A Randomized Comparison of Delivered Energy in Cardioversion of Atrial Fibrillation: Biphasic Truncated Exponential Versus Pulsed Biphasic Waveforms
A few randomized trials have compared impedance-compensated biphasic defibrillators in clinical use. We aim to compare pulsed biphasic (PB) and biphasic truncated exponential (BTE) waveforms in a non-inferiority cardioversion (CVS) study. This was a prospective monocentric randomized clinical trial....
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8235401/ https://www.ncbi.nlm.nih.gov/pubmed/34204498 http://dx.doi.org/10.3390/diagnostics11061107 |
_version_ | 1783714309044436992 |
---|---|
author | Trendafilova, Elina Dimitrova, Elena Didon, Jean-Philippe Krasteva, Vessela |
author_facet | Trendafilova, Elina Dimitrova, Elena Didon, Jean-Philippe Krasteva, Vessela |
author_sort | Trendafilova, Elina |
collection | PubMed |
description | A few randomized trials have compared impedance-compensated biphasic defibrillators in clinical use. We aim to compare pulsed biphasic (PB) and biphasic truncated exponential (BTE) waveforms in a non-inferiority cardioversion (CVS) study. This was a prospective monocentric randomized clinical trial. Eligible patients admitted for elective CVS of atrial fibrillation (AF) between February 2019 and March 2020 were alternately randomized to treatment with either a PB defibrillator (DEFIGARD TOUCH7, Schiller Médical, Wissembourg, France) or a BTE high-energy (BTE-HE) defibrillator (LIFEPAK15, Physio-Control Inc., Redmond, WA, USA). Fixed-energy protocol (200–200–200 J) was administered. CVS success was accepted if sinus rhythm was restored at 1 min post-shock. The study design considered non-inferiority testing of the primary outcome: cumulative delivered energy (CDE). Seventy-three out of 78 randomized patients received allocated intervention: 38 BTE-HE (52%), 35 PB (48%). Baseline characteristics were well-balanced between groups (p > 0.05). Both waveforms had similar CDE (mean ± standard deviation, 95% confidence interval): BTE-HE (253.9 ± 120.2 J, 214–293 J) vs. PB (226.0 ± 109.8 J, 188–264 J), p = 0.31. Indeed, effective PB shocks delivered significantly lower energies by mean of 25.6 J (95% CI 24–27.1 J, p < 0.001). Success rates were similar (BTE-HE vs. PB): 1 min first-shock (84.2% vs. 82.9%), 1 min CVS (97.4% vs. 94.3%), 2 h CVS (94.7% vs. 94.3%), 24 h CVS (92.1% vs. 94.3%), p > 0.05. Safety analysis did not find CVS hazards, reporting insignificant changes of myocardial-specific biomarkers, transient and rare ST-segment deviations, and no case of harmful tachyarrhythmias and apnea. Cardioversion of AF with fixed-energy protocol 200–200–200 J was highly efficient and safe for both PB and BTE-HE waveforms. These similar performances were achieved despite differences in the waveforms’ technical design, associated with significantly lower delivered energy for the effective PB shocks. Clinical Trial Registration: Registration number: NCT04032678, trial register: ClinicalTrials.gov. |
format | Online Article Text |
id | pubmed-8235401 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-82354012021-06-27 A Randomized Comparison of Delivered Energy in Cardioversion of Atrial Fibrillation: Biphasic Truncated Exponential Versus Pulsed Biphasic Waveforms Trendafilova, Elina Dimitrova, Elena Didon, Jean-Philippe Krasteva, Vessela Diagnostics (Basel) Article A few randomized trials have compared impedance-compensated biphasic defibrillators in clinical use. We aim to compare pulsed biphasic (PB) and biphasic truncated exponential (BTE) waveforms in a non-inferiority cardioversion (CVS) study. This was a prospective monocentric randomized clinical trial. Eligible patients admitted for elective CVS of atrial fibrillation (AF) between February 2019 and March 2020 were alternately randomized to treatment with either a PB defibrillator (DEFIGARD TOUCH7, Schiller Médical, Wissembourg, France) or a BTE high-energy (BTE-HE) defibrillator (LIFEPAK15, Physio-Control Inc., Redmond, WA, USA). Fixed-energy protocol (200–200–200 J) was administered. CVS success was accepted if sinus rhythm was restored at 1 min post-shock. The study design considered non-inferiority testing of the primary outcome: cumulative delivered energy (CDE). Seventy-three out of 78 randomized patients received allocated intervention: 38 BTE-HE (52%), 35 PB (48%). Baseline characteristics were well-balanced between groups (p > 0.05). Both waveforms had similar CDE (mean ± standard deviation, 95% confidence interval): BTE-HE (253.9 ± 120.2 J, 214–293 J) vs. PB (226.0 ± 109.8 J, 188–264 J), p = 0.31. Indeed, effective PB shocks delivered significantly lower energies by mean of 25.6 J (95% CI 24–27.1 J, p < 0.001). Success rates were similar (BTE-HE vs. PB): 1 min first-shock (84.2% vs. 82.9%), 1 min CVS (97.4% vs. 94.3%), 2 h CVS (94.7% vs. 94.3%), 24 h CVS (92.1% vs. 94.3%), p > 0.05. Safety analysis did not find CVS hazards, reporting insignificant changes of myocardial-specific biomarkers, transient and rare ST-segment deviations, and no case of harmful tachyarrhythmias and apnea. Cardioversion of AF with fixed-energy protocol 200–200–200 J was highly efficient and safe for both PB and BTE-HE waveforms. These similar performances were achieved despite differences in the waveforms’ technical design, associated with significantly lower delivered energy for the effective PB shocks. Clinical Trial Registration: Registration number: NCT04032678, trial register: ClinicalTrials.gov. MDPI 2021-06-17 /pmc/articles/PMC8235401/ /pubmed/34204498 http://dx.doi.org/10.3390/diagnostics11061107 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Trendafilova, Elina Dimitrova, Elena Didon, Jean-Philippe Krasteva, Vessela A Randomized Comparison of Delivered Energy in Cardioversion of Atrial Fibrillation: Biphasic Truncated Exponential Versus Pulsed Biphasic Waveforms |
title | A Randomized Comparison of Delivered Energy in Cardioversion of Atrial Fibrillation: Biphasic Truncated Exponential Versus Pulsed Biphasic Waveforms |
title_full | A Randomized Comparison of Delivered Energy in Cardioversion of Atrial Fibrillation: Biphasic Truncated Exponential Versus Pulsed Biphasic Waveforms |
title_fullStr | A Randomized Comparison of Delivered Energy in Cardioversion of Atrial Fibrillation: Biphasic Truncated Exponential Versus Pulsed Biphasic Waveforms |
title_full_unstemmed | A Randomized Comparison of Delivered Energy in Cardioversion of Atrial Fibrillation: Biphasic Truncated Exponential Versus Pulsed Biphasic Waveforms |
title_short | A Randomized Comparison of Delivered Energy in Cardioversion of Atrial Fibrillation: Biphasic Truncated Exponential Versus Pulsed Biphasic Waveforms |
title_sort | randomized comparison of delivered energy in cardioversion of atrial fibrillation: biphasic truncated exponential versus pulsed biphasic waveforms |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8235401/ https://www.ncbi.nlm.nih.gov/pubmed/34204498 http://dx.doi.org/10.3390/diagnostics11061107 |
work_keys_str_mv | AT trendafilovaelina arandomizedcomparisonofdeliveredenergyincardioversionofatrialfibrillationbiphasictruncatedexponentialversuspulsedbiphasicwaveforms AT dimitrovaelena arandomizedcomparisonofdeliveredenergyincardioversionofatrialfibrillationbiphasictruncatedexponentialversuspulsedbiphasicwaveforms AT didonjeanphilippe arandomizedcomparisonofdeliveredenergyincardioversionofatrialfibrillationbiphasictruncatedexponentialversuspulsedbiphasicwaveforms AT krastevavessela arandomizedcomparisonofdeliveredenergyincardioversionofatrialfibrillationbiphasictruncatedexponentialversuspulsedbiphasicwaveforms AT trendafilovaelina randomizedcomparisonofdeliveredenergyincardioversionofatrialfibrillationbiphasictruncatedexponentialversuspulsedbiphasicwaveforms AT dimitrovaelena randomizedcomparisonofdeliveredenergyincardioversionofatrialfibrillationbiphasictruncatedexponentialversuspulsedbiphasicwaveforms AT didonjeanphilippe randomizedcomparisonofdeliveredenergyincardioversionofatrialfibrillationbiphasictruncatedexponentialversuspulsedbiphasicwaveforms AT krastevavessela randomizedcomparisonofdeliveredenergyincardioversionofatrialfibrillationbiphasictruncatedexponentialversuspulsedbiphasicwaveforms |