Cargando…

Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience

SIMPLE SUMMARY: Traditionally, liver biopsy has been performed by percutaneous radiology-guided methods. Advances in endoscopic ultrasound have demonstrated the efficacy of endoscopic based techniques for liver biopsy. Studies comparing both methods are scarce and have conflicting results. Our study...

Descripción completa

Detalles Bibliográficos
Autores principales: Facciorusso, Antonio, Ramai, Daryl, Conti Bellocchi, Maria Cristina, Bernardoni, Laura, Manfrin, Erminia, Muscatiello, Nicola, Crinò, Stefano Francesco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8235406/
https://www.ncbi.nlm.nih.gov/pubmed/34205389
http://dx.doi.org/10.3390/cancers13123062
_version_ 1783714310216744960
author Facciorusso, Antonio
Ramai, Daryl
Conti Bellocchi, Maria Cristina
Bernardoni, Laura
Manfrin, Erminia
Muscatiello, Nicola
Crinò, Stefano Francesco
author_facet Facciorusso, Antonio
Ramai, Daryl
Conti Bellocchi, Maria Cristina
Bernardoni, Laura
Manfrin, Erminia
Muscatiello, Nicola
Crinò, Stefano Francesco
author_sort Facciorusso, Antonio
collection PubMed
description SIMPLE SUMMARY: Traditionally, liver biopsy has been performed by percutaneous radiology-guided methods. Advances in endoscopic ultrasound have demonstrated the efficacy of endoscopic based techniques for liver biopsy. Studies comparing both methods are scarce and have conflicting results. Our study compares percutaneous and endoscopic ultrasound methods for liver biopsy. Our analysis shows no evidence to support the wide use of endoscopic ultrasound. Percutaneous liver biopsy remains the sampling method of choice in this field. ABSTRACT: There is scarce and conflicting evidence on the comparison between endoscopic ultrasound (EUS) and percutaneous (PC)-guided liver biopsy (LB). The aim of this study was to compare the two approaches in a series of patients with parenchymal and focal liver lesions. Fifty-four patients undergoing EUS-LB in two high-volume centers between 2017 and 2021 were compared to 62 patients who underwent PC-LB. The primary outcome was diagnostic adequacy rate. The secondary outcomes were diagnostic accuracy, total sample length (TSL), number of complete portal tracts (CPTs), procedural duration, and adverse events. Variables were compared using the Chi-square and Mann–Whitney test. Median age was 56 years (interquartile range 48–69) in the EUS-LB group and 54 years (45–67) in the PC-LB group with most patients being male. Indication for LB was due to parenchymal disease in 50% of patients, whereas the other patients underwent LB due to focal liver lesions. Diagnostic adequacy was 100% in PC-LB and 94.4% in the EUS-LB group (p = 0.74), whereas diagnostic accuracy was 88.8% in the EUS-LB group and 100% in the PC-LB group (p = 0.82). Median TSL was significantly greater in the PC-LB group (27.4 mm, IQR 21–29) when compared to the EUS-LB group (18.5 mm, 10.1–22.4; p = 0.02). The number of complete portal tracts was 21 (11–24) in the PC-LB group and 18.5 (10–23.2) in EUS-LB group (p = 0.09). EUS-LB was a significantly longer procedure (7 min, 5–11 versus 1 min, 1–3 of PC-LB; p < 0.001) and no evidence of adverse events was observed in any of the study groups. These results were confirmed in the subgroup analysis performed according to an indication for LB (parenchymal disease versus focal lesion). Although PC-LB yielded specimens with greater TSL, diagnostic adequacy and accuracy were similar between the two procedures.
format Online
Article
Text
id pubmed-8235406
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82354062021-06-27 Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience Facciorusso, Antonio Ramai, Daryl Conti Bellocchi, Maria Cristina Bernardoni, Laura Manfrin, Erminia Muscatiello, Nicola Crinò, Stefano Francesco Cancers (Basel) Article SIMPLE SUMMARY: Traditionally, liver biopsy has been performed by percutaneous radiology-guided methods. Advances in endoscopic ultrasound have demonstrated the efficacy of endoscopic based techniques for liver biopsy. Studies comparing both methods are scarce and have conflicting results. Our study compares percutaneous and endoscopic ultrasound methods for liver biopsy. Our analysis shows no evidence to support the wide use of endoscopic ultrasound. Percutaneous liver biopsy remains the sampling method of choice in this field. ABSTRACT: There is scarce and conflicting evidence on the comparison between endoscopic ultrasound (EUS) and percutaneous (PC)-guided liver biopsy (LB). The aim of this study was to compare the two approaches in a series of patients with parenchymal and focal liver lesions. Fifty-four patients undergoing EUS-LB in two high-volume centers between 2017 and 2021 were compared to 62 patients who underwent PC-LB. The primary outcome was diagnostic adequacy rate. The secondary outcomes were diagnostic accuracy, total sample length (TSL), number of complete portal tracts (CPTs), procedural duration, and adverse events. Variables were compared using the Chi-square and Mann–Whitney test. Median age was 56 years (interquartile range 48–69) in the EUS-LB group and 54 years (45–67) in the PC-LB group with most patients being male. Indication for LB was due to parenchymal disease in 50% of patients, whereas the other patients underwent LB due to focal liver lesions. Diagnostic adequacy was 100% in PC-LB and 94.4% in the EUS-LB group (p = 0.74), whereas diagnostic accuracy was 88.8% in the EUS-LB group and 100% in the PC-LB group (p = 0.82). Median TSL was significantly greater in the PC-LB group (27.4 mm, IQR 21–29) when compared to the EUS-LB group (18.5 mm, 10.1–22.4; p = 0.02). The number of complete portal tracts was 21 (11–24) in the PC-LB group and 18.5 (10–23.2) in EUS-LB group (p = 0.09). EUS-LB was a significantly longer procedure (7 min, 5–11 versus 1 min, 1–3 of PC-LB; p < 0.001) and no evidence of adverse events was observed in any of the study groups. These results were confirmed in the subgroup analysis performed according to an indication for LB (parenchymal disease versus focal lesion). Although PC-LB yielded specimens with greater TSL, diagnostic adequacy and accuracy were similar between the two procedures. MDPI 2021-06-19 /pmc/articles/PMC8235406/ /pubmed/34205389 http://dx.doi.org/10.3390/cancers13123062 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Facciorusso, Antonio
Ramai, Daryl
Conti Bellocchi, Maria Cristina
Bernardoni, Laura
Manfrin, Erminia
Muscatiello, Nicola
Crinò, Stefano Francesco
Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience
title Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience
title_full Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience
title_fullStr Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience
title_full_unstemmed Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience
title_short Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience
title_sort diagnostic yield of endoscopic ultrasound-guided liver biopsy in comparison to percutaneous liver biopsy: a two-center experience
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8235406/
https://www.ncbi.nlm.nih.gov/pubmed/34205389
http://dx.doi.org/10.3390/cancers13123062
work_keys_str_mv AT facciorussoantonio diagnosticyieldofendoscopicultrasoundguidedliverbiopsyincomparisontopercutaneousliverbiopsyatwocenterexperience
AT ramaidaryl diagnosticyieldofendoscopicultrasoundguidedliverbiopsyincomparisontopercutaneousliverbiopsyatwocenterexperience
AT contibellocchimariacristina diagnosticyieldofendoscopicultrasoundguidedliverbiopsyincomparisontopercutaneousliverbiopsyatwocenterexperience
AT bernardonilaura diagnosticyieldofendoscopicultrasoundguidedliverbiopsyincomparisontopercutaneousliverbiopsyatwocenterexperience
AT manfrinerminia diagnosticyieldofendoscopicultrasoundguidedliverbiopsyincomparisontopercutaneousliverbiopsyatwocenterexperience
AT muscatiellonicola diagnosticyieldofendoscopicultrasoundguidedliverbiopsyincomparisontopercutaneousliverbiopsyatwocenterexperience
AT crinostefanofrancesco diagnosticyieldofendoscopicultrasoundguidedliverbiopsyincomparisontopercutaneousliverbiopsyatwocenterexperience