Cargando…

Equivalent Dose and Risk of Exposure Induced Cancer Death of Different Organs due to Various Image Techniques of EOS Imaging System

BACKGROUND: Euronext Paris Advanced Orthopedic Solutions (EOS) system is a new radiography system, capable of obtaining two-dimensional and three-dimensional images from bony structures in the body. OBJECTIVE: The aim of this study is to estimate equivalent dose and the risk of exposure induced canc...

Descripción completa

Detalles Bibliográficos
Autores principales: Hamzian, Nima, Afereydoon, Saeid, Ghorbani, Mahdi, Abrisham, Seyed Mohammad Jalil, Roozmand, Zahra, Abdollahi-Dehkordi, Sepideh, Sepehr Javan, Morteza, Reza Deevband, Mohammad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8236105/
https://www.ncbi.nlm.nih.gov/pubmed/34189117
http://dx.doi.org/10.31661/jbpe.v0i0.2012-1242
_version_ 1783714469427281920
author Hamzian, Nima
Afereydoon, Saeid
Ghorbani, Mahdi
Abrisham, Seyed Mohammad Jalil
Roozmand, Zahra
Abdollahi-Dehkordi, Sepideh
Sepehr Javan, Morteza
Reza Deevband, Mohammad
author_facet Hamzian, Nima
Afereydoon, Saeid
Ghorbani, Mahdi
Abrisham, Seyed Mohammad Jalil
Roozmand, Zahra
Abdollahi-Dehkordi, Sepideh
Sepehr Javan, Morteza
Reza Deevband, Mohammad
author_sort Hamzian, Nima
collection PubMed
description BACKGROUND: Euronext Paris Advanced Orthopedic Solutions (EOS) system is a new radiography system, capable of obtaining two-dimensional and three-dimensional images from bony structures in the body. OBJECTIVE: The aim of this study is to estimate equivalent dose and the risk of exposure induced cancer death (REID) in different organs of body due to EOS imaging system. MATERIAL AND METHODS: In this experimental study, totally 120 patients were evaluated for various imaging techniques of lower limb, full spine and whole body. Equivalent dose and REID for colon, liver, lung, stomach, breast, bladder, ovary, blood cells (leukemia) and other organs were calculated using PCXMC software (version 2.0.1.2) based on Monte Carlo simulation of X-ray and human phantoms. The data on imaging technique, including age, sex, kVp, dose area product (DAP), mA, focal to detector distance were introduced as the input of PCXMC. RESULTS: The maximum equivalent dose (mSv) due to EOS imaging system, was estimated for the bladder 0.240±0.066 for the full body technique and 0.240±0.093 for the lower limb technique, respectively, in both males and females. The maximum organ REID (incidence per million) due to EOS imaging system was estimated for lungs as 2.59±1.0 and 2.53±0.9, for the full body technique in both males and females, respectively. CONCLUSION: Generally, the equivalent dose and REID by EOS imaging system in different organs of body is low due to the low radiation dose received by the body in different techniques and views.
format Online
Article
Text
id pubmed-8236105
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-82361052021-06-28 Equivalent Dose and Risk of Exposure Induced Cancer Death of Different Organs due to Various Image Techniques of EOS Imaging System Hamzian, Nima Afereydoon, Saeid Ghorbani, Mahdi Abrisham, Seyed Mohammad Jalil Roozmand, Zahra Abdollahi-Dehkordi, Sepideh Sepehr Javan, Morteza Reza Deevband, Mohammad J Biomed Phys Eng Original Article BACKGROUND: Euronext Paris Advanced Orthopedic Solutions (EOS) system is a new radiography system, capable of obtaining two-dimensional and three-dimensional images from bony structures in the body. OBJECTIVE: The aim of this study is to estimate equivalent dose and the risk of exposure induced cancer death (REID) in different organs of body due to EOS imaging system. MATERIAL AND METHODS: In this experimental study, totally 120 patients were evaluated for various imaging techniques of lower limb, full spine and whole body. Equivalent dose and REID for colon, liver, lung, stomach, breast, bladder, ovary, blood cells (leukemia) and other organs were calculated using PCXMC software (version 2.0.1.2) based on Monte Carlo simulation of X-ray and human phantoms. The data on imaging technique, including age, sex, kVp, dose area product (DAP), mA, focal to detector distance were introduced as the input of PCXMC. RESULTS: The maximum equivalent dose (mSv) due to EOS imaging system, was estimated for the bladder 0.240±0.066 for the full body technique and 0.240±0.093 for the lower limb technique, respectively, in both males and females. The maximum organ REID (incidence per million) due to EOS imaging system was estimated for lungs as 2.59±1.0 and 2.53±0.9, for the full body technique in both males and females, respectively. CONCLUSION: Generally, the equivalent dose and REID by EOS imaging system in different organs of body is low due to the low radiation dose received by the body in different techniques and views. Shiraz University of Medical Sciences 2021-06-01 /pmc/articles/PMC8236105/ /pubmed/34189117 http://dx.doi.org/10.31661/jbpe.v0i0.2012-1242 Text en Copyright: © Journal of Biomedical Physics and Engineering https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 Unported License, ( http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hamzian, Nima
Afereydoon, Saeid
Ghorbani, Mahdi
Abrisham, Seyed Mohammad Jalil
Roozmand, Zahra
Abdollahi-Dehkordi, Sepideh
Sepehr Javan, Morteza
Reza Deevband, Mohammad
Equivalent Dose and Risk of Exposure Induced Cancer Death of Different Organs due to Various Image Techniques of EOS Imaging System
title Equivalent Dose and Risk of Exposure Induced Cancer Death of Different Organs due to Various Image Techniques of EOS Imaging System
title_full Equivalent Dose and Risk of Exposure Induced Cancer Death of Different Organs due to Various Image Techniques of EOS Imaging System
title_fullStr Equivalent Dose and Risk of Exposure Induced Cancer Death of Different Organs due to Various Image Techniques of EOS Imaging System
title_full_unstemmed Equivalent Dose and Risk of Exposure Induced Cancer Death of Different Organs due to Various Image Techniques of EOS Imaging System
title_short Equivalent Dose and Risk of Exposure Induced Cancer Death of Different Organs due to Various Image Techniques of EOS Imaging System
title_sort equivalent dose and risk of exposure induced cancer death of different organs due to various image techniques of eos imaging system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8236105/
https://www.ncbi.nlm.nih.gov/pubmed/34189117
http://dx.doi.org/10.31661/jbpe.v0i0.2012-1242
work_keys_str_mv AT hamziannima equivalentdoseandriskofexposureinducedcancerdeathofdifferentorgansduetovariousimagetechniquesofeosimagingsystem
AT afereydoonsaeid equivalentdoseandriskofexposureinducedcancerdeathofdifferentorgansduetovariousimagetechniquesofeosimagingsystem
AT ghorbanimahdi equivalentdoseandriskofexposureinducedcancerdeathofdifferentorgansduetovariousimagetechniquesofeosimagingsystem
AT abrishamseyedmohammadjalil equivalentdoseandriskofexposureinducedcancerdeathofdifferentorgansduetovariousimagetechniquesofeosimagingsystem
AT roozmandzahra equivalentdoseandriskofexposureinducedcancerdeathofdifferentorgansduetovariousimagetechniquesofeosimagingsystem
AT abdollahidehkordisepideh equivalentdoseandriskofexposureinducedcancerdeathofdifferentorgansduetovariousimagetechniquesofeosimagingsystem
AT sepehrjavanmorteza equivalentdoseandriskofexposureinducedcancerdeathofdifferentorgansduetovariousimagetechniquesofeosimagingsystem
AT rezadeevbandmohammad equivalentdoseandriskofexposureinducedcancerdeathofdifferentorgansduetovariousimagetechniquesofeosimagingsystem