Cargando…
Acute Mechanical Performance of Magmaris vs. DESolve Bioresorbable Scaffolds in a Real-World Scenario
Background: After the bioresorbable PLLA-based vascular scaffold (Absorb BVS) was taken from the market due to its high adverse event rates, a magnesium-based scaffold (Magmaris) was introduced. Objective: To compare the acute performance of the sirolimus-eluting magnesium alloy Magmaris scaffold wi...
Autores principales: | Boeder, Niklas F., Dörr, Oliver, Koepp, Tim, Blachutzik, Florian, Achenbach, Stephan, Elsässer, Albrecht, Hamm, Christian W., Nef, Holger M. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8236697/ https://www.ncbi.nlm.nih.gov/pubmed/34195239 http://dx.doi.org/10.3389/fcvm.2021.696287 |
Ejemplares similares
-
Clinical presentation does not affect acute mechanical performance of the Novolimus-eluting bioresorbable vascular scaffold as assessed by optical coherence tomography
por: Boeder, Niklas F., et al.
Publicado: (2021) -
Incidental Finding of Strut Malapposition Is a Predictor of Late and Very Late Thrombosis in Coronary Bioresorbable Scaffolds
por: Boeder, Niklas F., et al.
Publicado: (2019) -
First case report of fully robotically assisted lithotripsy in heavily calcified left main stenosis
por: Hofmann, Felix J, et al.
Publicado: (2022) -
Serial invasive imaging follow‐up of the first clinical experience with the Magmaris magnesium bioresorbable scaffold
por: Tovar Forero, Maria Natalia, et al.
Publicado: (2019) -
Long-Term Performance of the Magmaris Drug-Eluting Bioresorbable Metallic Scaffold in All-Comers Patients’ Population
por: Al Nooryani, Arif, et al.
Publicado: (2022)