Balloon Expandable Transcatheter Aortic Valve Implantation in Failing Self-Expandable Transcatheter Valve in Degenerated Surgical Bioprosthesis: Valve-in-Valve-in-Valve Implantation for the Treatment of Early Degenerative Prosthetic Insufficiency
Background: Transcatheter aortic valve implantation (TAVI) has emerged as the standard of care for patients with severe aortic stenosis who are at high surgical risk. However, transcatheter valves can degenerate, and redo TAVI has been reported after surgical aortic valve implantation and post initi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Academic Division of Ochsner Clinic Foundation
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8238102/ https://www.ncbi.nlm.nih.gov/pubmed/34239384 http://dx.doi.org/10.31486/toj.20.0011 |
_version_ | 1783714841502941184 |
---|---|
author | Subahi, Ahmed Alhusain, Rashid Ajmal, Rasikh Sohal, Chaman Ali, Omar E. |
author_facet | Subahi, Ahmed Alhusain, Rashid Ajmal, Rasikh Sohal, Chaman Ali, Omar E. |
author_sort | Subahi, Ahmed |
collection | PubMed |
description | Background: Transcatheter aortic valve implantation (TAVI) has emerged as the standard of care for patients with severe aortic stenosis who are at high surgical risk. However, transcatheter valves can degenerate, and redo TAVI has been reported after surgical aortic valve implantation and post initial TAVI. Case Report: We describe the case of a 70-year-old male who presented with decompensated heart failure secondary to severe prosthetic valve insufficiency. The patient had a history of distant triple coronary artery bypass surgery in 2004, surgical ascending aortic aneurysm repair and stentless aortic valve replacement in 2012, and transcatheter CoreValve (Medtronic) implantation in 2015 for the failing stentless aortic valve. In 2019, the patient presented with heart failure symptoms. A 29-mm SAPIEN 3 valve (Edwards Lifesciences) was implanted for the third time (valve-in-valve-in-valve) with excellent clinical and echocardiographic results and no evidence of coronary obstruction. Conclusion: Early (<5 years) bioprosthetic valve insufficiency after initial valve-in-valve implantation can be successfully treated with a second TAVI. |
format | Online Article Text |
id | pubmed-8238102 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Academic Division of Ochsner Clinic Foundation |
record_format | MEDLINE/PubMed |
spelling | pubmed-82381022021-07-07 Balloon Expandable Transcatheter Aortic Valve Implantation in Failing Self-Expandable Transcatheter Valve in Degenerated Surgical Bioprosthesis: Valve-in-Valve-in-Valve Implantation for the Treatment of Early Degenerative Prosthetic Insufficiency Subahi, Ahmed Alhusain, Rashid Ajmal, Rasikh Sohal, Chaman Ali, Omar E. Ochsner J Case Reports and Clinical Observations Background: Transcatheter aortic valve implantation (TAVI) has emerged as the standard of care for patients with severe aortic stenosis who are at high surgical risk. However, transcatheter valves can degenerate, and redo TAVI has been reported after surgical aortic valve implantation and post initial TAVI. Case Report: We describe the case of a 70-year-old male who presented with decompensated heart failure secondary to severe prosthetic valve insufficiency. The patient had a history of distant triple coronary artery bypass surgery in 2004, surgical ascending aortic aneurysm repair and stentless aortic valve replacement in 2012, and transcatheter CoreValve (Medtronic) implantation in 2015 for the failing stentless aortic valve. In 2019, the patient presented with heart failure symptoms. A 29-mm SAPIEN 3 valve (Edwards Lifesciences) was implanted for the third time (valve-in-valve-in-valve) with excellent clinical and echocardiographic results and no evidence of coronary obstruction. Conclusion: Early (<5 years) bioprosthetic valve insufficiency after initial valve-in-valve implantation can be successfully treated with a second TAVI. Academic Division of Ochsner Clinic Foundation 2021 2021 /pmc/articles/PMC8238102/ /pubmed/34239384 http://dx.doi.org/10.31486/toj.20.0011 Text en ©2021 by the author(s); Creative Commons Attribution License (CC BY) https://creativecommons.org/licenses/by/4.0/©2021 by the author(s); licensee Ochsner Journal, Ochsner Clinic Foundation, New Orleans, LA. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (creativecommons.org/licenses/by/4.0/legalcode) that permits unrestricted use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Case Reports and Clinical Observations Subahi, Ahmed Alhusain, Rashid Ajmal, Rasikh Sohal, Chaman Ali, Omar E. Balloon Expandable Transcatheter Aortic Valve Implantation in Failing Self-Expandable Transcatheter Valve in Degenerated Surgical Bioprosthesis: Valve-in-Valve-in-Valve Implantation for the Treatment of Early Degenerative Prosthetic Insufficiency |
title | Balloon Expandable Transcatheter Aortic Valve Implantation in Failing Self-Expandable Transcatheter Valve in Degenerated Surgical Bioprosthesis: Valve-in-Valve-in-Valve Implantation for the Treatment of Early Degenerative Prosthetic Insufficiency |
title_full | Balloon Expandable Transcatheter Aortic Valve Implantation in Failing Self-Expandable Transcatheter Valve in Degenerated Surgical Bioprosthesis: Valve-in-Valve-in-Valve Implantation for the Treatment of Early Degenerative Prosthetic Insufficiency |
title_fullStr | Balloon Expandable Transcatheter Aortic Valve Implantation in Failing Self-Expandable Transcatheter Valve in Degenerated Surgical Bioprosthesis: Valve-in-Valve-in-Valve Implantation for the Treatment of Early Degenerative Prosthetic Insufficiency |
title_full_unstemmed | Balloon Expandable Transcatheter Aortic Valve Implantation in Failing Self-Expandable Transcatheter Valve in Degenerated Surgical Bioprosthesis: Valve-in-Valve-in-Valve Implantation for the Treatment of Early Degenerative Prosthetic Insufficiency |
title_short | Balloon Expandable Transcatheter Aortic Valve Implantation in Failing Self-Expandable Transcatheter Valve in Degenerated Surgical Bioprosthesis: Valve-in-Valve-in-Valve Implantation for the Treatment of Early Degenerative Prosthetic Insufficiency |
title_sort | balloon expandable transcatheter aortic valve implantation in failing self-expandable transcatheter valve in degenerated surgical bioprosthesis: valve-in-valve-in-valve implantation for the treatment of early degenerative prosthetic insufficiency |
topic | Case Reports and Clinical Observations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8238102/ https://www.ncbi.nlm.nih.gov/pubmed/34239384 http://dx.doi.org/10.31486/toj.20.0011 |
work_keys_str_mv | AT subahiahmed balloonexpandabletranscatheteraorticvalveimplantationinfailingselfexpandabletranscathetervalveindegeneratedsurgicalbioprosthesisvalveinvalveinvalveimplantationforthetreatmentofearlydegenerativeprostheticinsufficiency AT alhusainrashid balloonexpandabletranscatheteraorticvalveimplantationinfailingselfexpandabletranscathetervalveindegeneratedsurgicalbioprosthesisvalveinvalveinvalveimplantationforthetreatmentofearlydegenerativeprostheticinsufficiency AT ajmalrasikh balloonexpandabletranscatheteraorticvalveimplantationinfailingselfexpandabletranscathetervalveindegeneratedsurgicalbioprosthesisvalveinvalveinvalveimplantationforthetreatmentofearlydegenerativeprostheticinsufficiency AT sohalchaman balloonexpandabletranscatheteraorticvalveimplantationinfailingselfexpandabletranscathetervalveindegeneratedsurgicalbioprosthesisvalveinvalveinvalveimplantationforthetreatmentofearlydegenerativeprostheticinsufficiency AT aliomare balloonexpandabletranscatheteraorticvalveimplantationinfailingselfexpandabletranscathetervalveindegeneratedsurgicalbioprosthesisvalveinvalveinvalveimplantationforthetreatmentofearlydegenerativeprostheticinsufficiency |