Cargando…

Improvement of short straws for sperm cryopreservation: installing an air-permeable filter facilitates handling

Saving space for sperm cryopreservation would aid mouse genetics research. We previously developed the ST (sperm freezing in ShorT STraw to reduce STorage space) method for cryopreserving mouse sperm in a smaller storage space than conventional methods. However, our ST method has two drawbacks: diff...

Descripción completa

Detalles Bibliográficos
Autores principales: KANEKO, Ryosuke, KAKINUMA, Toshie, SATO, Sachiko, JINNO-OUE, Atsushi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society for Reproduction and Development 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8238672/
https://www.ncbi.nlm.nih.gov/pubmed/33853994
http://dx.doi.org/10.1262/jrd.2021-019
_version_ 1783714949341642752
author KANEKO, Ryosuke
KAKINUMA, Toshie
SATO, Sachiko
JINNO-OUE, Atsushi
author_facet KANEKO, Ryosuke
KAKINUMA, Toshie
SATO, Sachiko
JINNO-OUE, Atsushi
author_sort KANEKO, Ryosuke
collection PubMed
description Saving space for sperm cryopreservation would aid mouse genetics research. We previously developed the ST (sperm freezing in ShorT STraw to reduce STorage space) method for cryopreserving mouse sperm in a smaller storage space than conventional methods. However, our ST method has two drawbacks: difficulties during freeze-thaw procedures and the potential risk of sperm loss during storage. Here, we refine ST, terming the new method improved ST (iST). In iST, the straw has an air-permeable filter and the straw container (2-ml cryotube) is endowed with air vents. As in our ST method, iST frozen-thawed sperm showed good performance upon in vitro fertilization. Moreover, up to nine straws can be stored in one cryotube, occupying less storage space than conventional methods. This method provides an easy and space-saving cryopreservation method for mouse sperm, and thus will be valuable for mouse genetics researchers.
format Online
Article
Text
id pubmed-8238672
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Society for Reproduction and Development
record_format MEDLINE/PubMed
spelling pubmed-82386722021-07-01 Improvement of short straws for sperm cryopreservation: installing an air-permeable filter facilitates handling KANEKO, Ryosuke KAKINUMA, Toshie SATO, Sachiko JINNO-OUE, Atsushi J Reprod Dev Technology Report Saving space for sperm cryopreservation would aid mouse genetics research. We previously developed the ST (sperm freezing in ShorT STraw to reduce STorage space) method for cryopreserving mouse sperm in a smaller storage space than conventional methods. However, our ST method has two drawbacks: difficulties during freeze-thaw procedures and the potential risk of sperm loss during storage. Here, we refine ST, terming the new method improved ST (iST). In iST, the straw has an air-permeable filter and the straw container (2-ml cryotube) is endowed with air vents. As in our ST method, iST frozen-thawed sperm showed good performance upon in vitro fertilization. Moreover, up to nine straws can be stored in one cryotube, occupying less storage space than conventional methods. This method provides an easy and space-saving cryopreservation method for mouse sperm, and thus will be valuable for mouse genetics researchers. The Society for Reproduction and Development 2021-04-14 2021-06 /pmc/articles/PMC8238672/ /pubmed/33853994 http://dx.doi.org/10.1262/jrd.2021-019 Text en ©2021 Society for Reproduction and Development https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Technology Report
KANEKO, Ryosuke
KAKINUMA, Toshie
SATO, Sachiko
JINNO-OUE, Atsushi
Improvement of short straws for sperm cryopreservation: installing an air-permeable filter facilitates handling
title Improvement of short straws for sperm cryopreservation: installing an air-permeable filter facilitates handling
title_full Improvement of short straws for sperm cryopreservation: installing an air-permeable filter facilitates handling
title_fullStr Improvement of short straws for sperm cryopreservation: installing an air-permeable filter facilitates handling
title_full_unstemmed Improvement of short straws for sperm cryopreservation: installing an air-permeable filter facilitates handling
title_short Improvement of short straws for sperm cryopreservation: installing an air-permeable filter facilitates handling
title_sort improvement of short straws for sperm cryopreservation: installing an air-permeable filter facilitates handling
topic Technology Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8238672/
https://www.ncbi.nlm.nih.gov/pubmed/33853994
http://dx.doi.org/10.1262/jrd.2021-019
work_keys_str_mv AT kanekoryosuke improvementofshortstrawsforspermcryopreservationinstallinganairpermeablefilterfacilitateshandling
AT kakinumatoshie improvementofshortstrawsforspermcryopreservationinstallinganairpermeablefilterfacilitateshandling
AT satosachiko improvementofshortstrawsforspermcryopreservationinstallinganairpermeablefilterfacilitateshandling
AT jinnooueatsushi improvementofshortstrawsforspermcryopreservationinstallinganairpermeablefilterfacilitateshandling