Cargando…
Triggering of Thumb by a Ganglion Cyst of the Flexor Tendon Sheath at A1 Pulley: A Case Report
INTRODUCTION: Ganglions of the wrist and hand are commonly seen but the most common sites are in the dorsum of the wrist followed by the volar side in the distal forearm at the wrist crease. The Ganglion cysts arising from the flexor tendon sheath are rare and only a few are reported in the literatu...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241247/ https://www.ncbi.nlm.nih.gov/pubmed/34239820 http://dx.doi.org/10.13107/jocr.2021.v11.i03.2064 |
_version_ | 1783715372244926464 |
---|---|
author | Altaf, Warid Attarde, Dheeraj Sancheti, Parag Shyam, Ashok |
author_facet | Altaf, Warid Attarde, Dheeraj Sancheti, Parag Shyam, Ashok |
author_sort | Altaf, Warid |
collection | PubMed |
description | INTRODUCTION: Ganglions of the wrist and hand are commonly seen but the most common sites are in the dorsum of the wrist followed by the volar side in the distal forearm at the wrist crease. The Ganglion cysts arising from the flexor tendon sheath are rare and only a few are reported in the literature. CASE REPORT: We report a rare case of a ganglion cyst of the flexor tendon sheath at A1 pulley of thumb in a 35-year-old male who came with the complaint of chronic triggering of the left thumb. The histopathological examination confirmed the ganglion which was removed from the A1 pulley area. CONCLUSION: A1 pulley ganglion causing trigger thumb is uncommon entity. Although, traditional treatment for this is conservative or aspiration. High recurrence is observed. When it comes to preservation of fine movements such as thumb, aggressive approach involving exploration and excision of cyst gives good functional outcome and reduces chance of recurrence. |
format | Online Article Text |
id | pubmed-8241247 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-82412472021-07-07 Triggering of Thumb by a Ganglion Cyst of the Flexor Tendon Sheath at A1 Pulley: A Case Report Altaf, Warid Attarde, Dheeraj Sancheti, Parag Shyam, Ashok J Orthop Case Rep Case Report INTRODUCTION: Ganglions of the wrist and hand are commonly seen but the most common sites are in the dorsum of the wrist followed by the volar side in the distal forearm at the wrist crease. The Ganglion cysts arising from the flexor tendon sheath are rare and only a few are reported in the literature. CASE REPORT: We report a rare case of a ganglion cyst of the flexor tendon sheath at A1 pulley of thumb in a 35-year-old male who came with the complaint of chronic triggering of the left thumb. The histopathological examination confirmed the ganglion which was removed from the A1 pulley area. CONCLUSION: A1 pulley ganglion causing trigger thumb is uncommon entity. Although, traditional treatment for this is conservative or aspiration. High recurrence is observed. When it comes to preservation of fine movements such as thumb, aggressive approach involving exploration and excision of cyst gives good functional outcome and reduces chance of recurrence. Indian Orthopaedic Research Group 2021-03 /pmc/articles/PMC8241247/ /pubmed/34239820 http://dx.doi.org/10.13107/jocr.2021.v11.i03.2064 Text en Copyright: © Indian Orthopaedic Research Group https://creativecommons.org/licenses/by-nc-sa/3.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Altaf, Warid Attarde, Dheeraj Sancheti, Parag Shyam, Ashok Triggering of Thumb by a Ganglion Cyst of the Flexor Tendon Sheath at A1 Pulley: A Case Report |
title | Triggering of Thumb by a Ganglion Cyst of the Flexor Tendon Sheath at A1 Pulley: A Case Report |
title_full | Triggering of Thumb by a Ganglion Cyst of the Flexor Tendon Sheath at A1 Pulley: A Case Report |
title_fullStr | Triggering of Thumb by a Ganglion Cyst of the Flexor Tendon Sheath at A1 Pulley: A Case Report |
title_full_unstemmed | Triggering of Thumb by a Ganglion Cyst of the Flexor Tendon Sheath at A1 Pulley: A Case Report |
title_short | Triggering of Thumb by a Ganglion Cyst of the Flexor Tendon Sheath at A1 Pulley: A Case Report |
title_sort | triggering of thumb by a ganglion cyst of the flexor tendon sheath at a1 pulley: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241247/ https://www.ncbi.nlm.nih.gov/pubmed/34239820 http://dx.doi.org/10.13107/jocr.2021.v11.i03.2064 |
work_keys_str_mv | AT altafwarid triggeringofthumbbyaganglioncystoftheflexortendonsheathata1pulleyacasereport AT attardedheeraj triggeringofthumbbyaganglioncystoftheflexortendonsheathata1pulleyacasereport AT sanchetiparag triggeringofthumbbyaganglioncystoftheflexortendonsheathata1pulleyacasereport AT shyamashok triggeringofthumbbyaganglioncystoftheflexortendonsheathata1pulleyacasereport |