Cargando…
Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy
BACKGROUND: Currently, CBCT system is an indispensable component of radiation therapy units. Because of that, it is important in treatment planning and diagnosis. CBCT is also an crucial tool for patient positioning and verification in image-guided radiation therapy (IGRT). Therefore, it is critical...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Via Medica
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241296/ https://www.ncbi.nlm.nih.gov/pubmed/34211776 http://dx.doi.org/10.5603/RPOR.a2021.0038 |
_version_ | 1783715382355296256 |
---|---|
author | Özseven, Alper Dirican, Bahar |
author_facet | Özseven, Alper Dirican, Bahar |
author_sort | Özseven, Alper |
collection | PubMed |
description | BACKGROUND: Currently, CBCT system is an indispensable component of radiation therapy units. Because of that, it is important in treatment planning and diagnosis. CBCT is also an crucial tool for patient positioning and verification in image-guided radiation therapy (IGRT). Therefore, it is critical to investigate the patient organ doses arising from CBCT imaging. The purpose of this study is to evaluate patient organ doses and effective dose to patients from three different protocols of Elekta Synergy XVI system for kV CBCT imaging examinations in image guided radiation therapy. MATERIALS AND METHODS: Organ dose measurements were done with thermoluminescent dosimeters in Alderson RA NDO male phantom for head & neck (H&N), chest and pelvis protocols of the Elekta Synergy XVI kV CBCT system. From the measured organ dose, effective dose to patients were calculated according to the International Commission on Radiological Protection 103 report recommendations. RESULTS: For H&N, chest and pelvis scans, the organ doses were in the range of 0.03–3.43 mGy, 6.04–22.94 mGy and 2.5–25.28 mGy, respectively. The calculated effective doses were 0.25 mSv, 5.56 mSv and 4.72 mSv, respectively. CONCLUSION: The obtained results were consistent with the most published studies in the literature. Although the doses to patient organs from the kV CBCT system were relatively low when compared with the prescribed treatment dose, the amount of delivered dose should be monitored and recorded carefully in order to avoid secondary cancer risk, especially in pediatric examinations. |
format | Online Article Text |
id | pubmed-8241296 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Via Medica |
record_format | MEDLINE/PubMed |
spelling | pubmed-82412962021-06-30 Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy Özseven, Alper Dirican, Bahar Rep Pract Oncol Radiother Research Paper BACKGROUND: Currently, CBCT system is an indispensable component of radiation therapy units. Because of that, it is important in treatment planning and diagnosis. CBCT is also an crucial tool for patient positioning and verification in image-guided radiation therapy (IGRT). Therefore, it is critical to investigate the patient organ doses arising from CBCT imaging. The purpose of this study is to evaluate patient organ doses and effective dose to patients from three different protocols of Elekta Synergy XVI system for kV CBCT imaging examinations in image guided radiation therapy. MATERIALS AND METHODS: Organ dose measurements were done with thermoluminescent dosimeters in Alderson RA NDO male phantom for head & neck (H&N), chest and pelvis protocols of the Elekta Synergy XVI kV CBCT system. From the measured organ dose, effective dose to patients were calculated according to the International Commission on Radiological Protection 103 report recommendations. RESULTS: For H&N, chest and pelvis scans, the organ doses were in the range of 0.03–3.43 mGy, 6.04–22.94 mGy and 2.5–25.28 mGy, respectively. The calculated effective doses were 0.25 mSv, 5.56 mSv and 4.72 mSv, respectively. CONCLUSION: The obtained results were consistent with the most published studies in the literature. Although the doses to patient organs from the kV CBCT system were relatively low when compared with the prescribed treatment dose, the amount of delivered dose should be monitored and recorded carefully in order to avoid secondary cancer risk, especially in pediatric examinations. Via Medica 2021-04-14 /pmc/articles/PMC8241296/ /pubmed/34211776 http://dx.doi.org/10.5603/RPOR.a2021.0038 Text en © 2021 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially |
spellingShingle | Research Paper Özseven, Alper Dirican, Bahar Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy |
title | Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy |
title_full | Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy |
title_fullStr | Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy |
title_full_unstemmed | Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy |
title_short | Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy |
title_sort | evaluation of patient organ doses from kilovoltage cone-beam ct imaging in radiation therapy |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241296/ https://www.ncbi.nlm.nih.gov/pubmed/34211776 http://dx.doi.org/10.5603/RPOR.a2021.0038 |
work_keys_str_mv | AT ozsevenalper evaluationofpatientorgandosesfromkilovoltageconebeamctimaginginradiationtherapy AT diricanbahar evaluationofpatientorgandosesfromkilovoltageconebeamctimaginginradiationtherapy |