Cargando…

Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy

BACKGROUND: Currently, CBCT system is an indispensable component of radiation therapy units. Because of that, it is important in treatment planning and diagnosis. CBCT is also an crucial tool for patient positioning and verification in image-guided radiation therapy (IGRT). Therefore, it is critical...

Descripción completa

Detalles Bibliográficos
Autores principales: Özseven, Alper, Dirican, Bahar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241296/
https://www.ncbi.nlm.nih.gov/pubmed/34211776
http://dx.doi.org/10.5603/RPOR.a2021.0038
_version_ 1783715382355296256
author Özseven, Alper
Dirican, Bahar
author_facet Özseven, Alper
Dirican, Bahar
author_sort Özseven, Alper
collection PubMed
description BACKGROUND: Currently, CBCT system is an indispensable component of radiation therapy units. Because of that, it is important in treatment planning and diagnosis. CBCT is also an crucial tool for patient positioning and verification in image-guided radiation therapy (IGRT). Therefore, it is critical to investigate the patient organ doses arising from CBCT imaging. The purpose of this study is to evaluate patient organ doses and effective dose to patients from three different protocols of Elekta Synergy XVI system for kV CBCT imaging examinations in image guided radiation therapy. MATERIALS AND METHODS: Organ dose measurements were done with thermoluminescent dosimeters in Alderson RA NDO male phantom for head & neck (H&N), chest and pelvis protocols of the Elekta Synergy XVI kV CBCT system. From the measured organ dose, effective dose to patients were calculated according to the International Commission on Radiological Protection 103 report recommendations. RESULTS: For H&N, chest and pelvis scans, the organ doses were in the range of 0.03–3.43 mGy, 6.04–22.94 mGy and 2.5–25.28 mGy, respectively. The calculated effective doses were 0.25 mSv, 5.56 mSv and 4.72 mSv, respectively. CONCLUSION: The obtained results were consistent with the most published studies in the literature. Although the doses to patient organs from the kV CBCT system were relatively low when compared with the prescribed treatment dose, the amount of delivered dose should be monitored and recorded carefully in order to avoid secondary cancer risk, especially in pediatric examinations.
format Online
Article
Text
id pubmed-8241296
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-82412962021-06-30 Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy Özseven, Alper Dirican, Bahar Rep Pract Oncol Radiother Research Paper BACKGROUND: Currently, CBCT system is an indispensable component of radiation therapy units. Because of that, it is important in treatment planning and diagnosis. CBCT is also an crucial tool for patient positioning and verification in image-guided radiation therapy (IGRT). Therefore, it is critical to investigate the patient organ doses arising from CBCT imaging. The purpose of this study is to evaluate patient organ doses and effective dose to patients from three different protocols of Elekta Synergy XVI system for kV CBCT imaging examinations in image guided radiation therapy. MATERIALS AND METHODS: Organ dose measurements were done with thermoluminescent dosimeters in Alderson RA NDO male phantom for head & neck (H&N), chest and pelvis protocols of the Elekta Synergy XVI kV CBCT system. From the measured organ dose, effective dose to patients were calculated according to the International Commission on Radiological Protection 103 report recommendations. RESULTS: For H&N, chest and pelvis scans, the organ doses were in the range of 0.03–3.43 mGy, 6.04–22.94 mGy and 2.5–25.28 mGy, respectively. The calculated effective doses were 0.25 mSv, 5.56 mSv and 4.72 mSv, respectively. CONCLUSION: The obtained results were consistent with the most published studies in the literature. Although the doses to patient organs from the kV CBCT system were relatively low when compared with the prescribed treatment dose, the amount of delivered dose should be monitored and recorded carefully in order to avoid secondary cancer risk, especially in pediatric examinations. Via Medica 2021-04-14 /pmc/articles/PMC8241296/ /pubmed/34211776 http://dx.doi.org/10.5603/RPOR.a2021.0038 Text en © 2021 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially
spellingShingle Research Paper
Özseven, Alper
Dirican, Bahar
Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy
title Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy
title_full Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy
title_fullStr Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy
title_full_unstemmed Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy
title_short Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy
title_sort evaluation of patient organ doses from kilovoltage cone-beam ct imaging in radiation therapy
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241296/
https://www.ncbi.nlm.nih.gov/pubmed/34211776
http://dx.doi.org/10.5603/RPOR.a2021.0038
work_keys_str_mv AT ozsevenalper evaluationofpatientorgandosesfromkilovoltageconebeamctimaginginradiationtherapy
AT diricanbahar evaluationofpatientorgandosesfromkilovoltageconebeamctimaginginradiationtherapy