Cargando…
Comparative dosimetrical analysis of intensity-modulated arc therapy, CyberKnife therapy and image-guided interstitial HDR and LDR brachytherapy of low risk prostate cancer
BACKGROUND: The objective of the study was to dosimetrically compare the intensity-modulated-arc-therapy (IMAT), Cyber-Knife therapy (CK), single fraction interstitial high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy (BT) in low-risk prostate cancer. MATERIALS AND METHODS: Treatment plans...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Via Medica
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241303/ https://www.ncbi.nlm.nih.gov/pubmed/34211769 http://dx.doi.org/10.5603/RPOR.a2021.0028 |
_version_ | 1783715384014143488 |
---|---|
author | Fröhlich, Georgina Ágoston, Péter Jorgo, Kliton Stelczer, Gábor Polgár, Csaba Major, Tibor |
author_facet | Fröhlich, Georgina Ágoston, Péter Jorgo, Kliton Stelczer, Gábor Polgár, Csaba Major, Tibor |
author_sort | Fröhlich, Georgina |
collection | PubMed |
description | BACKGROUND: The objective of the study was to dosimetrically compare the intensity-modulated-arc-therapy (IMAT), Cyber-Knife therapy (CK), single fraction interstitial high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy (BT) in low-risk prostate cancer. MATERIALS AND METHODS: Treatment plans of ten patients treated with CK were selected and additional plans using IMAT, HDR and LDR BT were created on the same CT images. The prescribed dose was 2.5/70 Gy in IMAT, 8/40 Gy in CK, 21 Gy in HDR and 145 Gy in LDR BT to the prostate gland. EQD2 dose-volume parameters were calculated for each technique and compared. RESULTS: EQD2 total dose of the prostate was significantly lower with IMAT and CK than with HDR and LDR BT, D90 was 79.5 Gy, 116.4 Gy, 169.2 Gy and 157.9 Gy (p < 0.001). However, teletherapy plans were more conformal than BT, COIN was 0.84, 0.82, 0.76 and 0.76 (p < 0.001), respectively. The D(2) to the rectum and bladder were lower with HDR BT than with IMAT, CK and LDR BT, it was 66.7 Gy, 68.1 Gy, 36.0 Gy and 68.0 Gy (p = 0.0427), and 68.4 Gy, 78.9 Gy, 51.4 Gy and 70.3 Gy (p = 0.0091) in IMAT, CK, HDR and LDR BT plans, while D(0.1) to the urethra was lower with both IMAT and CK than with BTs: 79.9 Gy, 88.0 Gy, 132.7 Gy and 170.6 Gy (p < 0.001). D(2) to the hips was higher with IMAT and CK, than with BTs: 13.4 Gy, 20.7 Gy, 0.4 Gy and 1.5 Gy (p < 0.001), while D(2) to the sigmoid, bowel bag, testicles and penile bulb was higher with CK than with the other techniques. CONCLUSIONS: HDR monotherapy yields the most advantageous dosimetrical plans, except for the dose to the urethra, where IMAT seems to be the optimal modality in the radiotherapy of low-risk prostate cancer. |
format | Online Article Text |
id | pubmed-8241303 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Via Medica |
record_format | MEDLINE/PubMed |
spelling | pubmed-82413032021-06-30 Comparative dosimetrical analysis of intensity-modulated arc therapy, CyberKnife therapy and image-guided interstitial HDR and LDR brachytherapy of low risk prostate cancer Fröhlich, Georgina Ágoston, Péter Jorgo, Kliton Stelczer, Gábor Polgár, Csaba Major, Tibor Rep Pract Oncol Radiother Research Paper BACKGROUND: The objective of the study was to dosimetrically compare the intensity-modulated-arc-therapy (IMAT), Cyber-Knife therapy (CK), single fraction interstitial high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy (BT) in low-risk prostate cancer. MATERIALS AND METHODS: Treatment plans of ten patients treated with CK were selected and additional plans using IMAT, HDR and LDR BT were created on the same CT images. The prescribed dose was 2.5/70 Gy in IMAT, 8/40 Gy in CK, 21 Gy in HDR and 145 Gy in LDR BT to the prostate gland. EQD2 dose-volume parameters were calculated for each technique and compared. RESULTS: EQD2 total dose of the prostate was significantly lower with IMAT and CK than with HDR and LDR BT, D90 was 79.5 Gy, 116.4 Gy, 169.2 Gy and 157.9 Gy (p < 0.001). However, teletherapy plans were more conformal than BT, COIN was 0.84, 0.82, 0.76 and 0.76 (p < 0.001), respectively. The D(2) to the rectum and bladder were lower with HDR BT than with IMAT, CK and LDR BT, it was 66.7 Gy, 68.1 Gy, 36.0 Gy and 68.0 Gy (p = 0.0427), and 68.4 Gy, 78.9 Gy, 51.4 Gy and 70.3 Gy (p = 0.0091) in IMAT, CK, HDR and LDR BT plans, while D(0.1) to the urethra was lower with both IMAT and CK than with BTs: 79.9 Gy, 88.0 Gy, 132.7 Gy and 170.6 Gy (p < 0.001). D(2) to the hips was higher with IMAT and CK, than with BTs: 13.4 Gy, 20.7 Gy, 0.4 Gy and 1.5 Gy (p < 0.001), while D(2) to the sigmoid, bowel bag, testicles and penile bulb was higher with CK than with the other techniques. CONCLUSIONS: HDR monotherapy yields the most advantageous dosimetrical plans, except for the dose to the urethra, where IMAT seems to be the optimal modality in the radiotherapy of low-risk prostate cancer. Via Medica 2021-04-14 /pmc/articles/PMC8241303/ /pubmed/34211769 http://dx.doi.org/10.5603/RPOR.a2021.0028 Text en © 2021 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially |
spellingShingle | Research Paper Fröhlich, Georgina Ágoston, Péter Jorgo, Kliton Stelczer, Gábor Polgár, Csaba Major, Tibor Comparative dosimetrical analysis of intensity-modulated arc therapy, CyberKnife therapy and image-guided interstitial HDR and LDR brachytherapy of low risk prostate cancer |
title | Comparative dosimetrical analysis of intensity-modulated arc therapy, CyberKnife therapy and image-guided interstitial HDR and LDR brachytherapy of low risk prostate cancer |
title_full | Comparative dosimetrical analysis of intensity-modulated arc therapy, CyberKnife therapy and image-guided interstitial HDR and LDR brachytherapy of low risk prostate cancer |
title_fullStr | Comparative dosimetrical analysis of intensity-modulated arc therapy, CyberKnife therapy and image-guided interstitial HDR and LDR brachytherapy of low risk prostate cancer |
title_full_unstemmed | Comparative dosimetrical analysis of intensity-modulated arc therapy, CyberKnife therapy and image-guided interstitial HDR and LDR brachytherapy of low risk prostate cancer |
title_short | Comparative dosimetrical analysis of intensity-modulated arc therapy, CyberKnife therapy and image-guided interstitial HDR and LDR brachytherapy of low risk prostate cancer |
title_sort | comparative dosimetrical analysis of intensity-modulated arc therapy, cyberknife therapy and image-guided interstitial hdr and ldr brachytherapy of low risk prostate cancer |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241303/ https://www.ncbi.nlm.nih.gov/pubmed/34211769 http://dx.doi.org/10.5603/RPOR.a2021.0028 |
work_keys_str_mv | AT frohlichgeorgina comparativedosimetricalanalysisofintensitymodulatedarctherapycyberknifetherapyandimageguidedinterstitialhdrandldrbrachytherapyoflowriskprostatecancer AT agostonpeter comparativedosimetricalanalysisofintensitymodulatedarctherapycyberknifetherapyandimageguidedinterstitialhdrandldrbrachytherapyoflowriskprostatecancer AT jorgokliton comparativedosimetricalanalysisofintensitymodulatedarctherapycyberknifetherapyandimageguidedinterstitialhdrandldrbrachytherapyoflowriskprostatecancer AT stelczergabor comparativedosimetricalanalysisofintensitymodulatedarctherapycyberknifetherapyandimageguidedinterstitialhdrandldrbrachytherapyoflowriskprostatecancer AT polgarcsaba comparativedosimetricalanalysisofintensitymodulatedarctherapycyberknifetherapyandimageguidedinterstitialhdrandldrbrachytherapyoflowriskprostatecancer AT majortibor comparativedosimetricalanalysisofintensitymodulatedarctherapycyberknifetherapyandimageguidedinterstitialhdrandldrbrachytherapyoflowriskprostatecancer |