Evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer

BACKGROUND: The aim of the study was to evaluate analysis criteria for the identification of the presence of rectal gas during volumetric modulated arc therapy (VMAT) for prostate cancer patients by using electronic portal imaging device (EPID)-based in vivo dosimetry (IVD). MATERIALS AND METHODS: A...

Descripción completa

Detalles Bibliográficos
Autores principales: Inui, Shoki, Ueda, Yoshihiro, Ono, Shunsuke, Ohira, Shingo, Isono, Masaru, Nitta, Yuya, Ueda, Hikari, Miyazaki, Masayoshi, Koizumi, Masahiko, Teshima, Teruki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241304/
https://www.ncbi.nlm.nih.gov/pubmed/34211779
http://dx.doi.org/10.5603/RPOR.a2021.0041
_version_ 1783715384244830208
author Inui, Shoki
Ueda, Yoshihiro
Ono, Shunsuke
Ohira, Shingo
Isono, Masaru
Nitta, Yuya
Ueda, Hikari
Miyazaki, Masayoshi
Koizumi, Masahiko
Teshima, Teruki
author_facet Inui, Shoki
Ueda, Yoshihiro
Ono, Shunsuke
Ohira, Shingo
Isono, Masaru
Nitta, Yuya
Ueda, Hikari
Miyazaki, Masayoshi
Koizumi, Masahiko
Teshima, Teruki
author_sort Inui, Shoki
collection PubMed
description BACKGROUND: The aim of the study was to evaluate analysis criteria for the identification of the presence of rectal gas during volumetric modulated arc therapy (VMAT) for prostate cancer patients by using electronic portal imaging device (EPID)-based in vivo dosimetry (IVD). MATERIALS AND METHODS: All measurements were performed by determining the cumulative EPID images in an integrated acquisition mode and analyzed using PerFRACTION commercial software. Systematic setup errors were simulated by moving the anthropomorphic phantom in each translational and rotational direction. The inhomogeneity regions were also simulated by the I’mRT phantom attached to the Quasar phantom. The presence of small and large air cavities (12 and 48 cm(3)) was controlled by moving the Quasar phantom in several timings during VMAT. Sixteen prostate cancer patients received EPID-based IVD during VMAT. RESULTS: In the phantom study, no systematic setup error was detected in the range that can happen in clinical (< 5-mm and < 3 degree). The pass rate of 2% dose difference (DD2%) in small and large air cavities was 98.74% and 79.05%, respectively, in the appearance of the air cavity after irradiation three quarter times. In the clinical study, some fractions caused a sharp decline in the DD2% pass rate. The proportion for DD2% < 90% was 13.4% of all fractions. Rectal gas was confirmed in 11.0% of fractions by acquiring kilo-voltage X-ray images after the treatment. CONCLUSIONS: Our results suggest that analysis criteria of 2% dose difference in EPID-based IVD was a suitable method for identification of rectal gas during VMAT for prostate cancer patients.
format Online
Article
Text
id pubmed-8241304
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-82413042021-06-30 Evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer Inui, Shoki Ueda, Yoshihiro Ono, Shunsuke Ohira, Shingo Isono, Masaru Nitta, Yuya Ueda, Hikari Miyazaki, Masayoshi Koizumi, Masahiko Teshima, Teruki Rep Pract Oncol Radiother Research Paper BACKGROUND: The aim of the study was to evaluate analysis criteria for the identification of the presence of rectal gas during volumetric modulated arc therapy (VMAT) for prostate cancer patients by using electronic portal imaging device (EPID)-based in vivo dosimetry (IVD). MATERIALS AND METHODS: All measurements were performed by determining the cumulative EPID images in an integrated acquisition mode and analyzed using PerFRACTION commercial software. Systematic setup errors were simulated by moving the anthropomorphic phantom in each translational and rotational direction. The inhomogeneity regions were also simulated by the I’mRT phantom attached to the Quasar phantom. The presence of small and large air cavities (12 and 48 cm(3)) was controlled by moving the Quasar phantom in several timings during VMAT. Sixteen prostate cancer patients received EPID-based IVD during VMAT. RESULTS: In the phantom study, no systematic setup error was detected in the range that can happen in clinical (< 5-mm and < 3 degree). The pass rate of 2% dose difference (DD2%) in small and large air cavities was 98.74% and 79.05%, respectively, in the appearance of the air cavity after irradiation three quarter times. In the clinical study, some fractions caused a sharp decline in the DD2% pass rate. The proportion for DD2% < 90% was 13.4% of all fractions. Rectal gas was confirmed in 11.0% of fractions by acquiring kilo-voltage X-ray images after the treatment. CONCLUSIONS: Our results suggest that analysis criteria of 2% dose difference in EPID-based IVD was a suitable method for identification of rectal gas during VMAT for prostate cancer patients. Via Medica 2021-04-14 /pmc/articles/PMC8241304/ /pubmed/34211779 http://dx.doi.org/10.5603/RPOR.a2021.0041 Text en © 2021 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially
spellingShingle Research Paper
Inui, Shoki
Ueda, Yoshihiro
Ono, Shunsuke
Ohira, Shingo
Isono, Masaru
Nitta, Yuya
Ueda, Hikari
Miyazaki, Masayoshi
Koizumi, Masahiko
Teshima, Teruki
Evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer
title Evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer
title_full Evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer
title_fullStr Evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer
title_full_unstemmed Evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer
title_short Evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer
title_sort evaluation of two-dimensional electronic portal imaging device using integrated images during volumetric modulated arc therapy for prostate cancer
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241304/
https://www.ncbi.nlm.nih.gov/pubmed/34211779
http://dx.doi.org/10.5603/RPOR.a2021.0041
work_keys_str_mv AT inuishoki evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer
AT uedayoshihiro evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer
AT onoshunsuke evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer
AT ohirashingo evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer
AT isonomasaru evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer
AT nittayuya evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer
AT uedahikari evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer
AT miyazakimasayoshi evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer
AT koizumimasahiko evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer
AT teshimateruki evaluationoftwodimensionalelectronicportalimagingdeviceusingintegratedimagesduringvolumetricmodulatedarctherapyforprostatecancer