Cargando…

Freisetzung von Aluminium aus Glitzerpartikeln bei herausnehmbaren kieferorthopädischen Apparaturen

BACKGROUND AND AIM: In order to support children’s compliance with orthodontic treatment, glitter particles containing aluminium (Al) are often embedded in the acrylic of removable appliances. When worn for up to 16 h daily for 2–3 years, it can be assumed that Al ions diffuse into saliva over time....

Descripción completa

Detalles Bibliográficos
Autores principales: Wepner, Lena, Färber, Harald Andreas, Weber, Anna, Jaensch, Andreas, Keilig, Ludger, Heuser, Florian Andreas, Bourauel, Christoph Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241636/
https://www.ncbi.nlm.nih.gov/pubmed/34115152
http://dx.doi.org/10.1007/s00103-021-03361-6
_version_ 1783715454460624896
author Wepner, Lena
Färber, Harald Andreas
Weber, Anna
Jaensch, Andreas
Keilig, Ludger
Heuser, Florian Andreas
Bourauel, Christoph Peter
author_facet Wepner, Lena
Färber, Harald Andreas
Weber, Anna
Jaensch, Andreas
Keilig, Ludger
Heuser, Florian Andreas
Bourauel, Christoph Peter
author_sort Wepner, Lena
collection PubMed
description BACKGROUND AND AIM: In order to support children’s compliance with orthodontic treatment, glitter particles containing aluminium (Al) are often embedded in the acrylic of removable appliances. When worn for up to 16 h daily for 2–3 years, it can be assumed that Al ions diffuse into saliva over time. The aim of this study was to investigate the release of Al ions from the acrylic using different orthodontic wires. MATERIALS AND METHOD: Test specimens (surface area 5.65 cm(2)) were prepared from orthodontic resin and various wires; half contained aluminium glitter particles. The test specimens were placed in Petri dishes containing 50 ml of corrosion medium (pH 2.3) according to DIN EN ISO 10271 at 37 °C for 7 days. Inductively coupled plasma mass spectrometry (ICP-MS) was used to quantify the specific ions in the corrosion solution. RESULTS: Statistical analysis showed a significant difference in the concentration of Al ions between samples with and without glitter particles. Concentrations from samples with glitter reached up to 14,474 μg/l Al ions; samples without glitter contained on average 1260 μg/l. A small proportion of the Al ions may originate from the alloys of the wires. CONCLUSIONS: It should be investigated whether the aluminium concentration can lead to health risks for humans. In view of the findings, orthodontists should not offer appliances containing glitter in order to minimize aluminium uptake with saliva. It needs to be clarified whether the conditions found in the oral cavity lead to the same results as under the abovementioned conditions. Legislation should be developed to limit the release of aluminium from orthodontic products.
format Online
Article
Text
id pubmed-8241636
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-82416362021-07-13 Freisetzung von Aluminium aus Glitzerpartikeln bei herausnehmbaren kieferorthopädischen Apparaturen Wepner, Lena Färber, Harald Andreas Weber, Anna Jaensch, Andreas Keilig, Ludger Heuser, Florian Andreas Bourauel, Christoph Peter Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz Leitthema BACKGROUND AND AIM: In order to support children’s compliance with orthodontic treatment, glitter particles containing aluminium (Al) are often embedded in the acrylic of removable appliances. When worn for up to 16 h daily for 2–3 years, it can be assumed that Al ions diffuse into saliva over time. The aim of this study was to investigate the release of Al ions from the acrylic using different orthodontic wires. MATERIALS AND METHOD: Test specimens (surface area 5.65 cm(2)) were prepared from orthodontic resin and various wires; half contained aluminium glitter particles. The test specimens were placed in Petri dishes containing 50 ml of corrosion medium (pH 2.3) according to DIN EN ISO 10271 at 37 °C for 7 days. Inductively coupled plasma mass spectrometry (ICP-MS) was used to quantify the specific ions in the corrosion solution. RESULTS: Statistical analysis showed a significant difference in the concentration of Al ions between samples with and without glitter particles. Concentrations from samples with glitter reached up to 14,474 μg/l Al ions; samples without glitter contained on average 1260 μg/l. A small proportion of the Al ions may originate from the alloys of the wires. CONCLUSIONS: It should be investigated whether the aluminium concentration can lead to health risks for humans. In view of the findings, orthodontists should not offer appliances containing glitter in order to minimize aluminium uptake with saliva. It needs to be clarified whether the conditions found in the oral cavity lead to the same results as under the abovementioned conditions. Legislation should be developed to limit the release of aluminium from orthodontic products. Springer Berlin Heidelberg 2021-06-11 2021 /pmc/articles/PMC8241636/ /pubmed/34115152 http://dx.doi.org/10.1007/s00103-021-03361-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access Dieser Artikel wird unter der Creative Commons Namensnennung 4.0 International Lizenz veröffentlicht, welche die Nutzung, Vervielfältigung, Bearbeitung, Verbreitung und Wiedergabe in jeglichem Medium und Format erlaubt, sofern Sie den/die ursprünglichen Autor(en) und die Quelle ordnungsgemäß nennen, einen Link zur Creative Commons Lizenz beifügen und angeben, ob Änderungen vorgenommen wurden. Die in diesem Artikel enthaltenen Bilder und sonstiges Drittmaterial unterliegen ebenfalls der genannten Creative Commons Lizenz, sofern sich aus der Abbildungslegende nichts anderes ergibt. Sofern das betreffende Material nicht unter der genannten Creative Commons Lizenz steht und die betreffende Handlung nicht nach gesetzlichen Vorschriften erlaubt ist, ist für die oben aufgeführten Weiterverwendungen des Materials die Einwilligung des jeweiligen Rechteinhabers einzuholen. Weitere Details zur Lizenz entnehmen Sie bitte der Lizenzinformation auf http://creativecommons.org/licenses/by/4.0/deed.de (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Leitthema
Wepner, Lena
Färber, Harald Andreas
Weber, Anna
Jaensch, Andreas
Keilig, Ludger
Heuser, Florian Andreas
Bourauel, Christoph Peter
Freisetzung von Aluminium aus Glitzerpartikeln bei herausnehmbaren kieferorthopädischen Apparaturen
title Freisetzung von Aluminium aus Glitzerpartikeln bei herausnehmbaren kieferorthopädischen Apparaturen
title_full Freisetzung von Aluminium aus Glitzerpartikeln bei herausnehmbaren kieferorthopädischen Apparaturen
title_fullStr Freisetzung von Aluminium aus Glitzerpartikeln bei herausnehmbaren kieferorthopädischen Apparaturen
title_full_unstemmed Freisetzung von Aluminium aus Glitzerpartikeln bei herausnehmbaren kieferorthopädischen Apparaturen
title_short Freisetzung von Aluminium aus Glitzerpartikeln bei herausnehmbaren kieferorthopädischen Apparaturen
title_sort freisetzung von aluminium aus glitzerpartikeln bei herausnehmbaren kieferorthopädischen apparaturen
topic Leitthema
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241636/
https://www.ncbi.nlm.nih.gov/pubmed/34115152
http://dx.doi.org/10.1007/s00103-021-03361-6
work_keys_str_mv AT wepnerlena freisetzungvonaluminiumausglitzerpartikelnbeiherausnehmbarenkieferorthopadischenapparaturen
AT farberharaldandreas freisetzungvonaluminiumausglitzerpartikelnbeiherausnehmbarenkieferorthopadischenapparaturen
AT weberanna freisetzungvonaluminiumausglitzerpartikelnbeiherausnehmbarenkieferorthopadischenapparaturen
AT jaenschandreas freisetzungvonaluminiumausglitzerpartikelnbeiherausnehmbarenkieferorthopadischenapparaturen
AT keiligludger freisetzungvonaluminiumausglitzerpartikelnbeiherausnehmbarenkieferorthopadischenapparaturen
AT heuserflorianandreas freisetzungvonaluminiumausglitzerpartikelnbeiherausnehmbarenkieferorthopadischenapparaturen
AT bourauelchristophpeter freisetzungvonaluminiumausglitzerpartikelnbeiherausnehmbarenkieferorthopadischenapparaturen