Cargando…

Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT

PURPOSE: To investigate the performance of the new long axial field-of-view (LAFOV) Biograph Vision Quadra PET/CT and a standard axial field-of-view (SAFOV) Biograph Vision 600 PET/CT (both: Siemens Healthineers) system using an intra-patient comparison. METHODS: Forty-four patients undergoing routi...

Descripción completa

Detalles Bibliográficos
Autores principales: Alberts, Ian, Hünermund, Jan-Niklas, Prenosil, George, Mingels, Clemens, Bohn, Karl Peter, Viscione, Marco, Sari, Hasan, Vollnberg, Bernd, Shi, Kuangyu, Afshar-Oromieh, Ali, Rominger, Axel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241747/
https://www.ncbi.nlm.nih.gov/pubmed/33797596
http://dx.doi.org/10.1007/s00259-021-05282-7
_version_ 1783715479275175936
author Alberts, Ian
Hünermund, Jan-Niklas
Prenosil, George
Mingels, Clemens
Bohn, Karl Peter
Viscione, Marco
Sari, Hasan
Vollnberg, Bernd
Shi, Kuangyu
Afshar-Oromieh, Ali
Rominger, Axel
author_facet Alberts, Ian
Hünermund, Jan-Niklas
Prenosil, George
Mingels, Clemens
Bohn, Karl Peter
Viscione, Marco
Sari, Hasan
Vollnberg, Bernd
Shi, Kuangyu
Afshar-Oromieh, Ali
Rominger, Axel
author_sort Alberts, Ian
collection PubMed
description PURPOSE: To investigate the performance of the new long axial field-of-view (LAFOV) Biograph Vision Quadra PET/CT and a standard axial field-of-view (SAFOV) Biograph Vision 600 PET/CT (both: Siemens Healthineers) system using an intra-patient comparison. METHODS: Forty-four patients undergoing routine oncological PET/CT were prospectively included and underwent a same-day dual-scanning protocol following a single administration of either (18)F-FDG (n = 20), (18)F-PSMA-1007 (n = 16) or (68)Ga-DOTA-TOC (n = 8). Half the patients first received a clinically routine examination on the SAFOV (FOV(axial) 26.3 cm) in continuous bed motion and then immediately afterwards on the LAFOV system (10-min acquisition in list mode, FOV(axial) 106 cm); the second half underwent scanning in the reverse order. Comparisons between the LAFOV at different emulated scan times (by rebinning list mode data) and the SAFOV were made for target lesion integral activity, signal to noise (SNR), target lesion to background ratio (TBR) and visual image quality. RESULTS: Equivalent target lesion integral activity to the SAFOV acquisitions (16-min duration for a 106 cm FOV) were obtained on the LAFOV in 1.63 ± 0.19 min (mean ± standard error). Equivalent SNR was obtained by 1.82 ± 1.00 min LAFOV acquisitions. No statistically significant differences (p > 0.05) in TBR were observed even for 0.5 min LAFOV examinations. Subjective image quality rated by two physicians confirmed the 10 min LAFOV to be of the highest quality, with equivalence between the LAFOV and the SAFOV at 1.8 ± 0.85 min. By analogy, if the LAFOV scans were maintained at 10 min, proportional reductions in applied radiopharmaceutical could obtain equivalent lesion integral activity for activities under 40 MBq and equivalent doses for the PET component of <1 mSv. CONCLUSION: Improved image quality, lesion quantification and SNR resulting from higher sensitivity were demonstrated for an LAFOV system in a head-to-head comparison under clinical conditions. The LAFOV system could deliver images of comparable quality and lesion quantification in under 2 min, compared to routine SAFOV acquisition (16 min for equivalent FOV coverage). Alternatively, the LAFOV system could allow for low-dose examination protocols. Shorter LAFOV acquisitions (0.5 min), while of lower visual quality and SNR, were of adequate quality with respect to target lesion identification, suggesting that ultra-fast or low-dose acquisitions can be acceptable in selected settings.
format Online
Article
Text
id pubmed-8241747
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-82417472021-07-14 Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT Alberts, Ian Hünermund, Jan-Niklas Prenosil, George Mingels, Clemens Bohn, Karl Peter Viscione, Marco Sari, Hasan Vollnberg, Bernd Shi, Kuangyu Afshar-Oromieh, Ali Rominger, Axel Eur J Nucl Med Mol Imaging Original Article PURPOSE: To investigate the performance of the new long axial field-of-view (LAFOV) Biograph Vision Quadra PET/CT and a standard axial field-of-view (SAFOV) Biograph Vision 600 PET/CT (both: Siemens Healthineers) system using an intra-patient comparison. METHODS: Forty-four patients undergoing routine oncological PET/CT were prospectively included and underwent a same-day dual-scanning protocol following a single administration of either (18)F-FDG (n = 20), (18)F-PSMA-1007 (n = 16) or (68)Ga-DOTA-TOC (n = 8). Half the patients first received a clinically routine examination on the SAFOV (FOV(axial) 26.3 cm) in continuous bed motion and then immediately afterwards on the LAFOV system (10-min acquisition in list mode, FOV(axial) 106 cm); the second half underwent scanning in the reverse order. Comparisons between the LAFOV at different emulated scan times (by rebinning list mode data) and the SAFOV were made for target lesion integral activity, signal to noise (SNR), target lesion to background ratio (TBR) and visual image quality. RESULTS: Equivalent target lesion integral activity to the SAFOV acquisitions (16-min duration for a 106 cm FOV) were obtained on the LAFOV in 1.63 ± 0.19 min (mean ± standard error). Equivalent SNR was obtained by 1.82 ± 1.00 min LAFOV acquisitions. No statistically significant differences (p > 0.05) in TBR were observed even for 0.5 min LAFOV examinations. Subjective image quality rated by two physicians confirmed the 10 min LAFOV to be of the highest quality, with equivalence between the LAFOV and the SAFOV at 1.8 ± 0.85 min. By analogy, if the LAFOV scans were maintained at 10 min, proportional reductions in applied radiopharmaceutical could obtain equivalent lesion integral activity for activities under 40 MBq and equivalent doses for the PET component of <1 mSv. CONCLUSION: Improved image quality, lesion quantification and SNR resulting from higher sensitivity were demonstrated for an LAFOV system in a head-to-head comparison under clinical conditions. The LAFOV system could deliver images of comparable quality and lesion quantification in under 2 min, compared to routine SAFOV acquisition (16 min for equivalent FOV coverage). Alternatively, the LAFOV system could allow for low-dose examination protocols. Shorter LAFOV acquisitions (0.5 min), while of lower visual quality and SNR, were of adequate quality with respect to target lesion identification, suggesting that ultra-fast or low-dose acquisitions can be acceptable in selected settings. Springer Berlin Heidelberg 2021-04-02 2021 /pmc/articles/PMC8241747/ /pubmed/33797596 http://dx.doi.org/10.1007/s00259-021-05282-7 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Alberts, Ian
Hünermund, Jan-Niklas
Prenosil, George
Mingels, Clemens
Bohn, Karl Peter
Viscione, Marco
Sari, Hasan
Vollnberg, Bernd
Shi, Kuangyu
Afshar-Oromieh, Ali
Rominger, Axel
Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT
title Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT
title_full Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT
title_fullStr Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT
title_full_unstemmed Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT
title_short Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT
title_sort clinical performance of long axial field of view pet/ct: a head-to-head intra-individual comparison of the biograph vision quadra with the biograph vision pet/ct
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241747/
https://www.ncbi.nlm.nih.gov/pubmed/33797596
http://dx.doi.org/10.1007/s00259-021-05282-7
work_keys_str_mv AT albertsian clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT hunermundjanniklas clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT prenosilgeorge clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT mingelsclemens clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT bohnkarlpeter clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT viscionemarco clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT sarihasan clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT vollnbergbernd clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT shikuangyu clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT afsharoromiehali clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct
AT romingeraxel clinicalperformanceoflongaxialfieldofviewpetctaheadtoheadintraindividualcomparisonofthebiographvisionquadrawiththebiographvisionpetct