Muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers

OBJECTIVE: To determine the value of shear wave elastography (SWE) in assessing abdominal wall muscles, including rectus abdominis (RA), external oblique muscle (EO), internal oblique muscle, and transversus abdominis (TrA) in patients with diastasis recti abdominis (DRA) and healthy controls. METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Kai, Zhou, Xiuling, Zhu, Yulan, Wang, Bo, Fu, Xiaojian, Yao, Qiyuan, Chen, Hao, Wang, Xiaohong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241952/
https://www.ncbi.nlm.nih.gov/pubmed/34185190
http://dx.doi.org/10.1186/s13244-021-01021-6
_version_ 1783715525187076096
author He, Kai
Zhou, Xiuling
Zhu, Yulan
Wang, Bo
Fu, Xiaojian
Yao, Qiyuan
Chen, Hao
Wang, Xiaohong
author_facet He, Kai
Zhou, Xiuling
Zhu, Yulan
Wang, Bo
Fu, Xiaojian
Yao, Qiyuan
Chen, Hao
Wang, Xiaohong
author_sort He, Kai
collection PubMed
description OBJECTIVE: To determine the value of shear wave elastography (SWE) in assessing abdominal wall muscles, including rectus abdominis (RA), external oblique muscle (EO), internal oblique muscle, and transversus abdominis (TrA) in patients with diastasis recti abdominis (DRA) and healthy controls. METHODS: From October 2018 to December 2019, 36 postpartum DRA patients and 24 nulliparous healthy women were identified. Inter-rectus distance (IRD) measurements were taken by B-mode ultrasound. Shear wave speed (SWS) values were acquired by one operator at ten specific locations. Clinical and ultrasound variables, including demographics, IRD, muscle thickness, and muscle SWS, were compared between the two groups using Student’s t test or Fisher's exact test. Pearson correlation analyses were conducted for the variables of IRD, muscle thickness, and SWS in the 36 DRA patients. RESULTS: The maximum diameter of recti abdominus separation was located at the umbilicus in DRA patients (4.59 ± 1.14 cm). The SWS value was significantly lower in the RA (p = 0.003) and higher in the TrA muscle (p < 0.001) in DRA patients compared with the age-matched controls. However, SWS in both muscles (RA and TrA) showed a statistically positive correlation with IRD (p < 0.05). In addition, the SWS value in EO statistically decreased in DRA patients compared with the healthy controls (1.65 ± 0.15 vs. 1.79 ± 0.14, p = 0.001). CONCLUSIONS: The application of SWE to abdominal wall muscles in DRA patients is feasible. The correlation between SWS value and IRD in RA should be interpreted with caution.
format Online
Article
Text
id pubmed-8241952
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-82419522021-07-13 Muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers He, Kai Zhou, Xiuling Zhu, Yulan Wang, Bo Fu, Xiaojian Yao, Qiyuan Chen, Hao Wang, Xiaohong Insights Imaging Original Article OBJECTIVE: To determine the value of shear wave elastography (SWE) in assessing abdominal wall muscles, including rectus abdominis (RA), external oblique muscle (EO), internal oblique muscle, and transversus abdominis (TrA) in patients with diastasis recti abdominis (DRA) and healthy controls. METHODS: From October 2018 to December 2019, 36 postpartum DRA patients and 24 nulliparous healthy women were identified. Inter-rectus distance (IRD) measurements were taken by B-mode ultrasound. Shear wave speed (SWS) values were acquired by one operator at ten specific locations. Clinical and ultrasound variables, including demographics, IRD, muscle thickness, and muscle SWS, were compared between the two groups using Student’s t test or Fisher's exact test. Pearson correlation analyses were conducted for the variables of IRD, muscle thickness, and SWS in the 36 DRA patients. RESULTS: The maximum diameter of recti abdominus separation was located at the umbilicus in DRA patients (4.59 ± 1.14 cm). The SWS value was significantly lower in the RA (p = 0.003) and higher in the TrA muscle (p < 0.001) in DRA patients compared with the age-matched controls. However, SWS in both muscles (RA and TrA) showed a statistically positive correlation with IRD (p < 0.05). In addition, the SWS value in EO statistically decreased in DRA patients compared with the healthy controls (1.65 ± 0.15 vs. 1.79 ± 0.14, p = 0.001). CONCLUSIONS: The application of SWE to abdominal wall muscles in DRA patients is feasible. The correlation between SWS value and IRD in RA should be interpreted with caution. Springer International Publishing 2021-06-29 /pmc/articles/PMC8241952/ /pubmed/34185190 http://dx.doi.org/10.1186/s13244-021-01021-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
He, Kai
Zhou, Xiuling
Zhu, Yulan
Wang, Bo
Fu, Xiaojian
Yao, Qiyuan
Chen, Hao
Wang, Xiaohong
Muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers
title Muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers
title_full Muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers
title_fullStr Muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers
title_full_unstemmed Muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers
title_short Muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers
title_sort muscle elasticity is different in individuals with diastasis recti abdominis than healthy volunteers
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241952/
https://www.ncbi.nlm.nih.gov/pubmed/34185190
http://dx.doi.org/10.1186/s13244-021-01021-6
work_keys_str_mv AT hekai muscleelasticityisdifferentinindividualswithdiastasisrectiabdoministhanhealthyvolunteers
AT zhouxiuling muscleelasticityisdifferentinindividualswithdiastasisrectiabdoministhanhealthyvolunteers
AT zhuyulan muscleelasticityisdifferentinindividualswithdiastasisrectiabdoministhanhealthyvolunteers
AT wangbo muscleelasticityisdifferentinindividualswithdiastasisrectiabdoministhanhealthyvolunteers
AT fuxiaojian muscleelasticityisdifferentinindividualswithdiastasisrectiabdoministhanhealthyvolunteers
AT yaoqiyuan muscleelasticityisdifferentinindividualswithdiastasisrectiabdoministhanhealthyvolunteers
AT chenhao muscleelasticityisdifferentinindividualswithdiastasisrectiabdoministhanhealthyvolunteers
AT wangxiaohong muscleelasticityisdifferentinindividualswithdiastasisrectiabdoministhanhealthyvolunteers