Cargando…

Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry

BACKGROUND: Recently, it has become possible to analyze implant placement position using the digital matching data of optical impression data of the oral cavity or plaster models with cone beam computed tomography (CBCT) data, and create a highly accurate surgical guide. It has been reported that CB...

Descripción completa

Detalles Bibliográficos
Autores principales: Komuro, Akira, Yamada, Yoichi, Uesugi, Satoshi, Terashima, Hiroaki, Kimura, Masashi, Kishimoto, Hiroto, Iida, Tsutomu, Sakamoto, Katsuya, Okuda, Kenichi, Kusano, Kaoru, Baba, Shunsuke, Sakamoto, Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241962/
https://www.ncbi.nlm.nih.gov/pubmed/34189641
http://dx.doi.org/10.1186/s40729-021-00343-w
_version_ 1783715526657179648
author Komuro, Akira
Yamada, Yoichi
Uesugi, Satoshi
Terashima, Hiroaki
Kimura, Masashi
Kishimoto, Hiroto
Iida, Tsutomu
Sakamoto, Katsuya
Okuda, Kenichi
Kusano, Kaoru
Baba, Shunsuke
Sakamoto, Takashi
author_facet Komuro, Akira
Yamada, Yoichi
Uesugi, Satoshi
Terashima, Hiroaki
Kimura, Masashi
Kishimoto, Hiroto
Iida, Tsutomu
Sakamoto, Katsuya
Okuda, Kenichi
Kusano, Kaoru
Baba, Shunsuke
Sakamoto, Takashi
author_sort Komuro, Akira
collection PubMed
description BACKGROUND: Recently, it has become possible to analyze implant placement position using the digital matching data of optical impression data of the oral cavity or plaster models with cone beam computed tomography (CBCT) data, and create a highly accurate surgical guide. It has been reported that CBCT measurements were smaller than the actual values, termed shrinkage. Matching of digital data is reliable when the plaster model or intraoral impression values show shrinkage at the same rate as the CBCT data. However, if the shrinkage rate is significantly different, the obtained digital data become unreliable. To clarify digital matching reliability, we examined dimensional reproducibility and shrinkage in measurements obtained with a model scanner, intra-oral scanner (iOS), and CBCT. MATERIALS AND METHODS: Three implants that were arranged in a triangle were fixed in an acrylic plate. The distance between each implants were measured using model scanner, iOS, and CBCT. The actual size measured by electronic caliper was regarded as control. RESULTS: All values measured with CBCT were significantly smaller than that of model scanner, iOS, and control (p<0.001). The model scanner shrinkage was 0.37-0.39%, iOS shrinkage was 0.9-1.4%, and CBCT shrinkage was 1.8-6.9%. There were statistically significant differences among the shrinkage with iOS, CBCT, and model scanner (p<0.001). CONCLUSION: Our findings showed that all measurements obtained with those modalities showed shrinkage as compared to the actual values. In addition, CBCT shrinkage was largest among three different measuring methods. They indicated that data matching between CBCT and scanner measurements requires attention in regard to the reliability of values obtained with those devices.
format Online
Article
Text
id pubmed-8241962
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-82419622021-07-13 Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry Komuro, Akira Yamada, Yoichi Uesugi, Satoshi Terashima, Hiroaki Kimura, Masashi Kishimoto, Hiroto Iida, Tsutomu Sakamoto, Katsuya Okuda, Kenichi Kusano, Kaoru Baba, Shunsuke Sakamoto, Takashi Int J Implant Dent Research BACKGROUND: Recently, it has become possible to analyze implant placement position using the digital matching data of optical impression data of the oral cavity or plaster models with cone beam computed tomography (CBCT) data, and create a highly accurate surgical guide. It has been reported that CBCT measurements were smaller than the actual values, termed shrinkage. Matching of digital data is reliable when the plaster model or intraoral impression values show shrinkage at the same rate as the CBCT data. However, if the shrinkage rate is significantly different, the obtained digital data become unreliable. To clarify digital matching reliability, we examined dimensional reproducibility and shrinkage in measurements obtained with a model scanner, intra-oral scanner (iOS), and CBCT. MATERIALS AND METHODS: Three implants that were arranged in a triangle were fixed in an acrylic plate. The distance between each implants were measured using model scanner, iOS, and CBCT. The actual size measured by electronic caliper was regarded as control. RESULTS: All values measured with CBCT were significantly smaller than that of model scanner, iOS, and control (p<0.001). The model scanner shrinkage was 0.37-0.39%, iOS shrinkage was 0.9-1.4%, and CBCT shrinkage was 1.8-6.9%. There were statistically significant differences among the shrinkage with iOS, CBCT, and model scanner (p<0.001). CONCLUSION: Our findings showed that all measurements obtained with those modalities showed shrinkage as compared to the actual values. In addition, CBCT shrinkage was largest among three different measuring methods. They indicated that data matching between CBCT and scanner measurements requires attention in regard to the reliability of values obtained with those devices. Springer Berlin Heidelberg 2021-06-30 /pmc/articles/PMC8241962/ /pubmed/34189641 http://dx.doi.org/10.1186/s40729-021-00343-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Komuro, Akira
Yamada, Yoichi
Uesugi, Satoshi
Terashima, Hiroaki
Kimura, Masashi
Kishimoto, Hiroto
Iida, Tsutomu
Sakamoto, Katsuya
Okuda, Kenichi
Kusano, Kaoru
Baba, Shunsuke
Sakamoto, Takashi
Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry
title Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry
title_full Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry
title_fullStr Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry
title_full_unstemmed Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry
title_short Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry
title_sort accuracy and dimensional reproducibility by model scanning, intraoral scanning, and cbct imaging for digital implant dentistry
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8241962/
https://www.ncbi.nlm.nih.gov/pubmed/34189641
http://dx.doi.org/10.1186/s40729-021-00343-w
work_keys_str_mv AT komuroakira accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT yamadayoichi accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT uesugisatoshi accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT terashimahiroaki accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT kimuramasashi accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT kishimotohiroto accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT iidatsutomu accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT sakamotokatsuya accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT okudakenichi accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT kusanokaoru accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT babashunsuke accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry
AT sakamototakashi accuracyanddimensionalreproducibilitybymodelscanningintraoralscanningandcbctimagingfordigitalimplantdentistry