Cargando…

Application Analysis of Positive-Pressure Connector in Invasive Blood Pressure Monitoring in Coronary Interventional Therapy

Background: In order to reduce the risk of invasive blood pressure monitoring and improve the safety and efficiency, this article mainly analyzes the effectiveness and safety of using positive-pressure connector for invasive blood pressure monitoring in patients with coronary artery interventional t...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Aili, Liu, Junying, Peng, Wanzhong, Jiang, Yang, Guo, Lina, Xu, Zesheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8242173/
https://www.ncbi.nlm.nih.gov/pubmed/34222318
http://dx.doi.org/10.3389/fsurg.2021.676310
_version_ 1783715574572908544
author Wang, Aili
Liu, Junying
Peng, Wanzhong
Jiang, Yang
Guo, Lina
Xu, Zesheng
author_facet Wang, Aili
Liu, Junying
Peng, Wanzhong
Jiang, Yang
Guo, Lina
Xu, Zesheng
author_sort Wang, Aili
collection PubMed
description Background: In order to reduce the risk of invasive blood pressure monitoring and improve the safety and efficiency, this article mainly analyzes the effectiveness and safety of using positive-pressure connector for invasive blood pressure monitoring in patients with coronary artery interventional therapy, so as to improve the invasive blood pressure monitoring method. Aim: To study and analyze the application of positive-pressure connector in invasive blood pressure monitoring in coronary interventional therapy. Methods: From October 2017 to October 2019, a total of 120 patients admitted to Cangzhou Central Hospital, Cangzhou, Hebei, China, for coronary interventional therapy with invasive blood pressure monitoring were selected and divided into a control group and an experimental group by drawing lots with 60 patients in each group. Positive-pressure connector was used for invasive blood pressure detection in the experimental group, and heparin cap connector was used for invasive blood pressure detection in the control group. The effectiveness and safety of blood pressure monitoring in the two groups were compared, and the influence of different joints on invasive blood pressure monitoring was analyzed. Results: The influencing factors of puncture efficiency in the experimental group (6.67%) were significantly lower than those in the control group (30.00%) (P < 0.05). There was no significant difference in catheter bending between the experimental group and the control group (P > 0.05). The experimental group exhibited a remarkably higher puncture safety rate (93%) compared to the control group (67%) (P < 0.05). There was no significant difference in arterial blood pressure between the two groups with different indwelling time (P > 0.05). The frequency of extubation and reinsertion in the experimental group was significantly lower than that in the control group (P < 0.05). Factors influencing puncture safety in the experimental group were significantly lower than those in the control group (P < 0.05). Conclusion: The use of positive-pressure connector for invasive blood pressure monitoring in patients with coronary artery interventional therapy can greatly improve the safety of blood pressure monitoring and reduce the suffering of patients. Therefore, the application of positive-pressure connector in invasive blood pressure monitoring is worthy of promotion and application in clinical practice.
format Online
Article
Text
id pubmed-8242173
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-82421732021-07-01 Application Analysis of Positive-Pressure Connector in Invasive Blood Pressure Monitoring in Coronary Interventional Therapy Wang, Aili Liu, Junying Peng, Wanzhong Jiang, Yang Guo, Lina Xu, Zesheng Front Surg Surgery Background: In order to reduce the risk of invasive blood pressure monitoring and improve the safety and efficiency, this article mainly analyzes the effectiveness and safety of using positive-pressure connector for invasive blood pressure monitoring in patients with coronary artery interventional therapy, so as to improve the invasive blood pressure monitoring method. Aim: To study and analyze the application of positive-pressure connector in invasive blood pressure monitoring in coronary interventional therapy. Methods: From October 2017 to October 2019, a total of 120 patients admitted to Cangzhou Central Hospital, Cangzhou, Hebei, China, for coronary interventional therapy with invasive blood pressure monitoring were selected and divided into a control group and an experimental group by drawing lots with 60 patients in each group. Positive-pressure connector was used for invasive blood pressure detection in the experimental group, and heparin cap connector was used for invasive blood pressure detection in the control group. The effectiveness and safety of blood pressure monitoring in the two groups were compared, and the influence of different joints on invasive blood pressure monitoring was analyzed. Results: The influencing factors of puncture efficiency in the experimental group (6.67%) were significantly lower than those in the control group (30.00%) (P < 0.05). There was no significant difference in catheter bending between the experimental group and the control group (P > 0.05). The experimental group exhibited a remarkably higher puncture safety rate (93%) compared to the control group (67%) (P < 0.05). There was no significant difference in arterial blood pressure between the two groups with different indwelling time (P > 0.05). The frequency of extubation and reinsertion in the experimental group was significantly lower than that in the control group (P < 0.05). Factors influencing puncture safety in the experimental group were significantly lower than those in the control group (P < 0.05). Conclusion: The use of positive-pressure connector for invasive blood pressure monitoring in patients with coronary artery interventional therapy can greatly improve the safety of blood pressure monitoring and reduce the suffering of patients. Therefore, the application of positive-pressure connector in invasive blood pressure monitoring is worthy of promotion and application in clinical practice. Frontiers Media S.A. 2021-06-16 /pmc/articles/PMC8242173/ /pubmed/34222318 http://dx.doi.org/10.3389/fsurg.2021.676310 Text en Copyright © 2021 Wang, Liu, Peng, Jiang, Guo and Xu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Wang, Aili
Liu, Junying
Peng, Wanzhong
Jiang, Yang
Guo, Lina
Xu, Zesheng
Application Analysis of Positive-Pressure Connector in Invasive Blood Pressure Monitoring in Coronary Interventional Therapy
title Application Analysis of Positive-Pressure Connector in Invasive Blood Pressure Monitoring in Coronary Interventional Therapy
title_full Application Analysis of Positive-Pressure Connector in Invasive Blood Pressure Monitoring in Coronary Interventional Therapy
title_fullStr Application Analysis of Positive-Pressure Connector in Invasive Blood Pressure Monitoring in Coronary Interventional Therapy
title_full_unstemmed Application Analysis of Positive-Pressure Connector in Invasive Blood Pressure Monitoring in Coronary Interventional Therapy
title_short Application Analysis of Positive-Pressure Connector in Invasive Blood Pressure Monitoring in Coronary Interventional Therapy
title_sort application analysis of positive-pressure connector in invasive blood pressure monitoring in coronary interventional therapy
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8242173/
https://www.ncbi.nlm.nih.gov/pubmed/34222318
http://dx.doi.org/10.3389/fsurg.2021.676310
work_keys_str_mv AT wangaili applicationanalysisofpositivepressureconnectorininvasivebloodpressuremonitoringincoronaryinterventionaltherapy
AT liujunying applicationanalysisofpositivepressureconnectorininvasivebloodpressuremonitoringincoronaryinterventionaltherapy
AT pengwanzhong applicationanalysisofpositivepressureconnectorininvasivebloodpressuremonitoringincoronaryinterventionaltherapy
AT jiangyang applicationanalysisofpositivepressureconnectorininvasivebloodpressuremonitoringincoronaryinterventionaltherapy
AT guolina applicationanalysisofpositivepressureconnectorininvasivebloodpressuremonitoringincoronaryinterventionaltherapy
AT xuzesheng applicationanalysisofpositivepressureconnectorininvasivebloodpressuremonitoringincoronaryinterventionaltherapy