Cargando…

Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment

AIMS: To extend the benefits of physiologically guided percutaneous coronary intervention to many more patients, angiography-derived, or ‘virtual’ fractional flow reserve (vFFR) has been developed, in which FFR is computed, based upon the images, instead of being measured invasively. The effect of o...

Descripción completa

Detalles Bibliográficos
Autores principales: Lal, Katherine, Gosling, Rebecca, Ghobrial, Mina, Williams, Gareth J, Rammohan, Vignesh, Hose, D Rod, Lawford, Patricia V, Narracott, Andrew, Fenner, John, Gunn, Julian P, Morris, Paul D
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8242185/
https://www.ncbi.nlm.nih.gov/pubmed/34223175
http://dx.doi.org/10.1093/ehjdh/ztab012
_version_ 1783715577619021824
author Lal, Katherine
Gosling, Rebecca
Ghobrial, Mina
Williams, Gareth J
Rammohan, Vignesh
Hose, D Rod
Lawford, Patricia V
Narracott, Andrew
Fenner, John
Gunn, Julian P
Morris, Paul D
author_facet Lal, Katherine
Gosling, Rebecca
Ghobrial, Mina
Williams, Gareth J
Rammohan, Vignesh
Hose, D Rod
Lawford, Patricia V
Narracott, Andrew
Fenner, John
Gunn, Julian P
Morris, Paul D
author_sort Lal, Katherine
collection PubMed
description AIMS: To extend the benefits of physiologically guided percutaneous coronary intervention to many more patients, angiography-derived, or ‘virtual’ fractional flow reserve (vFFR) has been developed, in which FFR is computed, based upon the images, instead of being measured invasively. The effect of operator experience with these methods upon vFFR accuracy remains unknown. We investigated variability in vFFR results based upon operator experience with image-based computational modelling techniques. METHODS AND RESULTS: Virtual fractional flow reserve was computed using a proprietary method (VIRTUheart) from the invasive angiograms of patients with coronary artery disease. Each case was processed by an expert (>100 vFFR cases) and a non-expert (<20 vFFR cases) operator and results were compared. The primary outcome was the variability in vFFR between experts and non-experts and the impact this had upon treatment strategy (PCI vs. conservative management). Two hundred and thirty-one vessels (199 patients) were processed. Mean non-expert and expert vFFRs were similar overall [0.76 (0.13) and 0.77 (0.16)] but there was significant variability between individual results (variability coefficient 12%, intraclass correlation coefficient 0.58), with only moderate agreement (κ = 0.46), and this led to a statistically significant change in management strategy in 27% of cases. Variability was significantly lower, and agreement higher, for expert operators; a change in their recommended management occurred in 10% of repeated expert measurements and 14% of inter-expert measurements. CONCLUSION: Virtual fractional flow reserve results are influenced by operator experience of vFFR processing. This had implications for treatment allocation. These results highlight the importance of training and quality assurance to ensure reliable, repeatable vFFR results.
format Online
Article
Text
id pubmed-8242185
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-82421852021-07-01 Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment Lal, Katherine Gosling, Rebecca Ghobrial, Mina Williams, Gareth J Rammohan, Vignesh Hose, D Rod Lawford, Patricia V Narracott, Andrew Fenner, John Gunn, Julian P Morris, Paul D Eur Heart J Digit Health Original Articles AIMS: To extend the benefits of physiologically guided percutaneous coronary intervention to many more patients, angiography-derived, or ‘virtual’ fractional flow reserve (vFFR) has been developed, in which FFR is computed, based upon the images, instead of being measured invasively. The effect of operator experience with these methods upon vFFR accuracy remains unknown. We investigated variability in vFFR results based upon operator experience with image-based computational modelling techniques. METHODS AND RESULTS: Virtual fractional flow reserve was computed using a proprietary method (VIRTUheart) from the invasive angiograms of patients with coronary artery disease. Each case was processed by an expert (>100 vFFR cases) and a non-expert (<20 vFFR cases) operator and results were compared. The primary outcome was the variability in vFFR between experts and non-experts and the impact this had upon treatment strategy (PCI vs. conservative management). Two hundred and thirty-one vessels (199 patients) were processed. Mean non-expert and expert vFFRs were similar overall [0.76 (0.13) and 0.77 (0.16)] but there was significant variability between individual results (variability coefficient 12%, intraclass correlation coefficient 0.58), with only moderate agreement (κ = 0.46), and this led to a statistically significant change in management strategy in 27% of cases. Variability was significantly lower, and agreement higher, for expert operators; a change in their recommended management occurred in 10% of repeated expert measurements and 14% of inter-expert measurements. CONCLUSION: Virtual fractional flow reserve results are influenced by operator experience of vFFR processing. This had implications for treatment allocation. These results highlight the importance of training and quality assurance to ensure reliable, repeatable vFFR results. Oxford University Press 2021-02-05 /pmc/articles/PMC8242185/ /pubmed/34223175 http://dx.doi.org/10.1093/ehjdh/ztab012 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Lal, Katherine
Gosling, Rebecca
Ghobrial, Mina
Williams, Gareth J
Rammohan, Vignesh
Hose, D Rod
Lawford, Patricia V
Narracott, Andrew
Fenner, John
Gunn, Julian P
Morris, Paul D
Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment
title Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment
title_full Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment
title_fullStr Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment
title_full_unstemmed Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment
title_short Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment
title_sort operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8242185/
https://www.ncbi.nlm.nih.gov/pubmed/34223175
http://dx.doi.org/10.1093/ehjdh/ztab012
work_keys_str_mv AT lalkatherine operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT goslingrebecca operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT ghobrialmina operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT williamsgarethj operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT rammohanvignesh operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT hosedrod operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT lawfordpatriciav operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT narracottandrew operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT fennerjohn operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT gunnjulianp operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment
AT morrispauld operatordependentvariabilityofangiographyderivedfractionalflowreserveandtheimplicationsfortreatment