Cargando…
Value of Contrast-Enhanced Ultrasonography in Evaluating Rheumatoid Arthritis: Preliminary Research Based on an Animal Model
BACKGROUND: The aim of this study was to evaluate the effectiveness of grayscale ultrasound (GSUS), power Doppler imaging (PDI), and contrast-enhanced ultrasonography (CEUS) in early rheumatoid arthritis (RA) diagnosis through animal experiments. MATERIAL/METHODS: A rabbit RA model was constructed....
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8243804/ https://www.ncbi.nlm.nih.gov/pubmed/34172694 http://dx.doi.org/10.12659/MSM.931327 |
_version_ | 1783715812781064192 |
---|---|
author | Gong, Yiran Huang, Yinan Su, Yiming He, Juxin Chen, Shuqiang |
author_facet | Gong, Yiran Huang, Yinan Su, Yiming He, Juxin Chen, Shuqiang |
author_sort | Gong, Yiran |
collection | PubMed |
description | BACKGROUND: The aim of this study was to evaluate the effectiveness of grayscale ultrasound (GSUS), power Doppler imaging (PDI), and contrast-enhanced ultrasonography (CEUS) in early rheumatoid arthritis (RA) diagnosis through animal experiments. MATERIAL/METHODS: A rabbit RA model was constructed. The animals were randomly divided into 2 groups, namely, the RA model group and the control group. GSUS, PDI, and CEUS were performed in the model group during early RA and were compared with pathology of synovial biopsies. The consistency of 3 types of ultrasonography was evaluated in tandem with pathological grading. RESULTS: 23 rabbits in the RA model group completed the experiment. GSUS showed that the synovial thickening of grades 1, 2 and 3 occurred in 12, 19, and 15 joints, respectively. The sensitivity, specificity, and accuracy of PDI in the diagnosis of knee joint synovitis in RA grades 1, 2, and 3 were 80.56% (29/36), 60.00% (6/10), and 76.09% (35/46), respectively, while those with CEUS were 94.44% (34/36), 90.00% (9/10), and 93.47% (43/46), respectively. The differences in diagnostic sensitivity, specificity, and accuracy of the 2 methods were statistically significant. Additionally, the thickness of the synovium measured with GSUS precontrast was greater than that of postcontrast. CONCLUSIONS: RA evaluated with GSUS is often more hypertrophied than when evaluated with CEUS, while evaluation by PDI is less hypertrophied than that by CEUS. However, from a practical view point, GSUS and PDI are of sufficient practical value, except for in a few special cases. |
format | Online Article Text |
id | pubmed-8243804 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-82438042021-07-14 Value of Contrast-Enhanced Ultrasonography in Evaluating Rheumatoid Arthritis: Preliminary Research Based on an Animal Model Gong, Yiran Huang, Yinan Su, Yiming He, Juxin Chen, Shuqiang Med Sci Monit Animal Study BACKGROUND: The aim of this study was to evaluate the effectiveness of grayscale ultrasound (GSUS), power Doppler imaging (PDI), and contrast-enhanced ultrasonography (CEUS) in early rheumatoid arthritis (RA) diagnosis through animal experiments. MATERIAL/METHODS: A rabbit RA model was constructed. The animals were randomly divided into 2 groups, namely, the RA model group and the control group. GSUS, PDI, and CEUS were performed in the model group during early RA and were compared with pathology of synovial biopsies. The consistency of 3 types of ultrasonography was evaluated in tandem with pathological grading. RESULTS: 23 rabbits in the RA model group completed the experiment. GSUS showed that the synovial thickening of grades 1, 2 and 3 occurred in 12, 19, and 15 joints, respectively. The sensitivity, specificity, and accuracy of PDI in the diagnosis of knee joint synovitis in RA grades 1, 2, and 3 were 80.56% (29/36), 60.00% (6/10), and 76.09% (35/46), respectively, while those with CEUS were 94.44% (34/36), 90.00% (9/10), and 93.47% (43/46), respectively. The differences in diagnostic sensitivity, specificity, and accuracy of the 2 methods were statistically significant. Additionally, the thickness of the synovium measured with GSUS precontrast was greater than that of postcontrast. CONCLUSIONS: RA evaluated with GSUS is often more hypertrophied than when evaluated with CEUS, while evaluation by PDI is less hypertrophied than that by CEUS. However, from a practical view point, GSUS and PDI are of sufficient practical value, except for in a few special cases. International Scientific Literature, Inc. 2021-06-26 /pmc/articles/PMC8243804/ /pubmed/34172694 http://dx.doi.org/10.12659/MSM.931327 Text en © Med Sci Monit, 2021 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Animal Study Gong, Yiran Huang, Yinan Su, Yiming He, Juxin Chen, Shuqiang Value of Contrast-Enhanced Ultrasonography in Evaluating Rheumatoid Arthritis: Preliminary Research Based on an Animal Model |
title | Value of Contrast-Enhanced Ultrasonography in Evaluating Rheumatoid Arthritis: Preliminary Research Based on an Animal Model |
title_full | Value of Contrast-Enhanced Ultrasonography in Evaluating Rheumatoid Arthritis: Preliminary Research Based on an Animal Model |
title_fullStr | Value of Contrast-Enhanced Ultrasonography in Evaluating Rheumatoid Arthritis: Preliminary Research Based on an Animal Model |
title_full_unstemmed | Value of Contrast-Enhanced Ultrasonography in Evaluating Rheumatoid Arthritis: Preliminary Research Based on an Animal Model |
title_short | Value of Contrast-Enhanced Ultrasonography in Evaluating Rheumatoid Arthritis: Preliminary Research Based on an Animal Model |
title_sort | value of contrast-enhanced ultrasonography in evaluating rheumatoid arthritis: preliminary research based on an animal model |
topic | Animal Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8243804/ https://www.ncbi.nlm.nih.gov/pubmed/34172694 http://dx.doi.org/10.12659/MSM.931327 |
work_keys_str_mv | AT gongyiran valueofcontrastenhancedultrasonographyinevaluatingrheumatoidarthritispreliminaryresearchbasedonananimalmodel AT huangyinan valueofcontrastenhancedultrasonographyinevaluatingrheumatoidarthritispreliminaryresearchbasedonananimalmodel AT suyiming valueofcontrastenhancedultrasonographyinevaluatingrheumatoidarthritispreliminaryresearchbasedonananimalmodel AT hejuxin valueofcontrastenhancedultrasonographyinevaluatingrheumatoidarthritispreliminaryresearchbasedonananimalmodel AT chenshuqiang valueofcontrastenhancedultrasonographyinevaluatingrheumatoidarthritispreliminaryresearchbasedonananimalmodel |