Cargando…

New Ag(3)PO(4) comparison material for stable oxygen isotope analysis

RATIONALE: A silver phosphate reference material (Ag(3)PO(4)) for the measurement of stable oxygen isotope compositions is much needed; however, it is not available from the authorities distributing reference materials. This study aims to fill this gap by calibrating a new Ag(3)PO(4) stable isotope...

Descripción completa

Detalles Bibliográficos
Autores principales: Watzinger, Andrea, Schott, Katharina, Hood‐Nowotny, Rebecca, Tamburini, Federica, Arppe, Laura, Cristini, Domiziana, Knöller, Kay, Skrzypek, Grzegorz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8243957/
https://www.ncbi.nlm.nih.gov/pubmed/33835608
http://dx.doi.org/10.1002/rcm.9101
_version_ 1783715834029408256
author Watzinger, Andrea
Schott, Katharina
Hood‐Nowotny, Rebecca
Tamburini, Federica
Arppe, Laura
Cristini, Domiziana
Knöller, Kay
Skrzypek, Grzegorz
author_facet Watzinger, Andrea
Schott, Katharina
Hood‐Nowotny, Rebecca
Tamburini, Federica
Arppe, Laura
Cristini, Domiziana
Knöller, Kay
Skrzypek, Grzegorz
author_sort Watzinger, Andrea
collection PubMed
description RATIONALE: A silver phosphate reference material (Ag(3)PO(4)) for the measurement of stable oxygen isotope compositions is much needed; however, it is not available from the authorities distributing reference materials. This study aims to fill this gap by calibrating a new Ag(3)PO(4) stable isotope comparison material produced by the University of Natural Resources and Life Sciences (BOKU). METHODS: Aliquots of Ag(3)PO(4) were distributed to four laboratories who frequently measure the δ (18)O value in Ag(3)PO(4); the University of Natural Resources and Life Sciences (BOKU), the University of Western Australia (UWA), the University of Helsinki (UH), and the Helmholtz Centre for Environmental Research (UFZ). The instruments used to perform the measurements were high‐temperature conversion elemental analysers coupled with continuous flow isotope ratio mass spectrometers. The working gas δ (18)O value was set to 0‰ and the normalization was done by a three‐point linear regression using the reference materials IAEA‐601, IAEA‐602, and NBS127. RESULTS: The mean δ (18)O value of the new BOKU Ag(3)PO(4) comparison material on the VSMOW‐SLAP scale is 13.71‰ and the combined uncertainty is estimated as ±0.34‰. This estimated uncertainty is within the range typical for comparison materials of phosphates and sulphates. Consistent results from the different laboratories probably derived from similar instrumentation, and use of the same reference materials and normalization procedure. The matrix effect of the different reference materials used in this study was deemed negligible. CONCLUSIONS: The BOKU Ag(3)PO(4) can be used as an alternative comparison material for stable oxygen isotope analysis and is available for stable isotope research laboratories to facilitate calibration.
format Online
Article
Text
id pubmed-8243957
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-82439572021-07-02 New Ag(3)PO(4) comparison material for stable oxygen isotope analysis Watzinger, Andrea Schott, Katharina Hood‐Nowotny, Rebecca Tamburini, Federica Arppe, Laura Cristini, Domiziana Knöller, Kay Skrzypek, Grzegorz Rapid Commun Mass Spectrom Research Articles RATIONALE: A silver phosphate reference material (Ag(3)PO(4)) for the measurement of stable oxygen isotope compositions is much needed; however, it is not available from the authorities distributing reference materials. This study aims to fill this gap by calibrating a new Ag(3)PO(4) stable isotope comparison material produced by the University of Natural Resources and Life Sciences (BOKU). METHODS: Aliquots of Ag(3)PO(4) were distributed to four laboratories who frequently measure the δ (18)O value in Ag(3)PO(4); the University of Natural Resources and Life Sciences (BOKU), the University of Western Australia (UWA), the University of Helsinki (UH), and the Helmholtz Centre for Environmental Research (UFZ). The instruments used to perform the measurements were high‐temperature conversion elemental analysers coupled with continuous flow isotope ratio mass spectrometers. The working gas δ (18)O value was set to 0‰ and the normalization was done by a three‐point linear regression using the reference materials IAEA‐601, IAEA‐602, and NBS127. RESULTS: The mean δ (18)O value of the new BOKU Ag(3)PO(4) comparison material on the VSMOW‐SLAP scale is 13.71‰ and the combined uncertainty is estimated as ±0.34‰. This estimated uncertainty is within the range typical for comparison materials of phosphates and sulphates. Consistent results from the different laboratories probably derived from similar instrumentation, and use of the same reference materials and normalization procedure. The matrix effect of the different reference materials used in this study was deemed negligible. CONCLUSIONS: The BOKU Ag(3)PO(4) can be used as an alternative comparison material for stable oxygen isotope analysis and is available for stable isotope research laboratories to facilitate calibration. John Wiley and Sons Inc. 2021-05-07 2021-06-30 /pmc/articles/PMC8243957/ /pubmed/33835608 http://dx.doi.org/10.1002/rcm.9101 Text en © 2021 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Research Articles
Watzinger, Andrea
Schott, Katharina
Hood‐Nowotny, Rebecca
Tamburini, Federica
Arppe, Laura
Cristini, Domiziana
Knöller, Kay
Skrzypek, Grzegorz
New Ag(3)PO(4) comparison material for stable oxygen isotope analysis
title New Ag(3)PO(4) comparison material for stable oxygen isotope analysis
title_full New Ag(3)PO(4) comparison material for stable oxygen isotope analysis
title_fullStr New Ag(3)PO(4) comparison material for stable oxygen isotope analysis
title_full_unstemmed New Ag(3)PO(4) comparison material for stable oxygen isotope analysis
title_short New Ag(3)PO(4) comparison material for stable oxygen isotope analysis
title_sort new ag(3)po(4) comparison material for stable oxygen isotope analysis
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8243957/
https://www.ncbi.nlm.nih.gov/pubmed/33835608
http://dx.doi.org/10.1002/rcm.9101
work_keys_str_mv AT watzingerandrea newag3po4comparisonmaterialforstableoxygenisotopeanalysis
AT schottkatharina newag3po4comparisonmaterialforstableoxygenisotopeanalysis
AT hoodnowotnyrebecca newag3po4comparisonmaterialforstableoxygenisotopeanalysis
AT tamburinifederica newag3po4comparisonmaterialforstableoxygenisotopeanalysis
AT arppelaura newag3po4comparisonmaterialforstableoxygenisotopeanalysis
AT cristinidomiziana newag3po4comparisonmaterialforstableoxygenisotopeanalysis
AT knollerkay newag3po4comparisonmaterialforstableoxygenisotopeanalysis
AT skrzypekgrzegorz newag3po4comparisonmaterialforstableoxygenisotopeanalysis