AIM: We explored the potential for over-compression from current paediatric chest compression depth guidelines using chest computed tomography(CT) images of a large, heterogenous, Asian population. METHODS: A retrospective review of consecutive children, less than 18-years old, with chest CT images...

Descripción completa

Detalles Bibliográficos
Autores principales: Ong, Gene Yong-Kwang, Ang, Aloysius Jian Feng, S O Aurangzeb, Amirzeb, Fong, Elisabeth Sue Shuen, Tan, Jun Yuan, Chen, Zhao Jin, Chan, Yiong Huak, Tang, Phua Hwee, Pek, Jen Heng, Maconochie, Ian, Ng, Kee Chong, Nadkarni, Vinay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8244421/
https://www.ncbi.nlm.nih.gov/pubmed/34223372
http://dx.doi.org/10.1016/j.resplu.2021.100112
_version_ 1783715930197458944
author Ong, Gene Yong-Kwang
Ang, Aloysius Jian Feng
S O Aurangzeb, Amirzeb
Fong, Elisabeth Sue Shuen
Tan, Jun Yuan
Chen, Zhao Jin
Chan, Yiong Huak
Tang, Phua Hwee
Pek, Jen Heng
Maconochie, Ian
Ng, Kee Chong
Nadkarni, Vinay
author_facet Ong, Gene Yong-Kwang
Ang, Aloysius Jian Feng
S O Aurangzeb, Amirzeb
Fong, Elisabeth Sue Shuen
Tan, Jun Yuan
Chen, Zhao Jin
Chan, Yiong Huak
Tang, Phua Hwee
Pek, Jen Heng
Maconochie, Ian
Ng, Kee Chong
Nadkarni, Vinay
author_sort Ong, Gene Yong-Kwang
collection PubMed
description AIM: We explored the potential for over-compression from current paediatric chest compression depth guidelines using chest computed tomography(CT) images of a large, heterogenous, Asian population. METHODS: A retrospective review of consecutive children, less than 18-years old, with chest CT images performed between from 2005 to 2017 was done. Demographic data were extracted from the electronic medical records. Measurements for internal and external anterior-posterior diameters (APD) were taken at lower half of the sternum. Simulated chest compressions were performed to evaluate the proportion of the population with residual internal cavity dimensions less than 0 mm (RICD < 0 mm, representing definite over-compression; with chest compression depth exceeding internal APD), and RICD less than 10 mm (RICD < 10 mm, representing potential over-compression). RESULTS: 592 paediatric chest CT studies were included for the study. Simulated chest compressions of one-third external APD had the least potential for over-compression; no infants and 0.3% children had potential over-compression (RICD < 10 mm). 4 cm simulated chest compressions led to 18% (95% CI 13%–24%) of infants with potential over-compression, and this increased to 34% (95% CI 27%–41%) at 4.4 cm (upper limit of “approximately” 4 cm; 4 cm + 10%). 5 cm simulated compressions resulted in 8% (95% CI 4%–12%) of children 1 to 8-years-old with potential over-compression, and this increased to 22% (95% CI 16%–28%) at 5.5 cm (upper limit of “approximately” 5 cm, 5 cm + 10%). CONCLUSION: In settings whereby chest compression depths can be accurately measured, compressions at the current recommended chest compression of approximately 4 cm (in infants) and 5 cm (in young children) could result in potential for over-compression.
format Online
Article
Text
id pubmed-8244421
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-82444212021-07-02 What is the potential for over-compression using current paediatric chest compression guidelines? — A chest computed tomography study Ong, Gene Yong-Kwang Ang, Aloysius Jian Feng S O Aurangzeb, Amirzeb Fong, Elisabeth Sue Shuen Tan, Jun Yuan Chen, Zhao Jin Chan, Yiong Huak Tang, Phua Hwee Pek, Jen Heng Maconochie, Ian Ng, Kee Chong Nadkarni, Vinay Resusc Plus Clinical Paper AIM: We explored the potential for over-compression from current paediatric chest compression depth guidelines using chest computed tomography(CT) images of a large, heterogenous, Asian population. METHODS: A retrospective review of consecutive children, less than 18-years old, with chest CT images performed between from 2005 to 2017 was done. Demographic data were extracted from the electronic medical records. Measurements for internal and external anterior-posterior diameters (APD) were taken at lower half of the sternum. Simulated chest compressions were performed to evaluate the proportion of the population with residual internal cavity dimensions less than 0 mm (RICD < 0 mm, representing definite over-compression; with chest compression depth exceeding internal APD), and RICD less than 10 mm (RICD < 10 mm, representing potential over-compression). RESULTS: 592 paediatric chest CT studies were included for the study. Simulated chest compressions of one-third external APD had the least potential for over-compression; no infants and 0.3% children had potential over-compression (RICD < 10 mm). 4 cm simulated chest compressions led to 18% (95% CI 13%–24%) of infants with potential over-compression, and this increased to 34% (95% CI 27%–41%) at 4.4 cm (upper limit of “approximately” 4 cm; 4 cm + 10%). 5 cm simulated compressions resulted in 8% (95% CI 4%–12%) of children 1 to 8-years-old with potential over-compression, and this increased to 22% (95% CI 16%–28%) at 5.5 cm (upper limit of “approximately” 5 cm, 5 cm + 10%). CONCLUSION: In settings whereby chest compression depths can be accurately measured, compressions at the current recommended chest compression of approximately 4 cm (in infants) and 5 cm (in young children) could result in potential for over-compression. Elsevier 2021-03-27 /pmc/articles/PMC8244421/ /pubmed/34223372 http://dx.doi.org/10.1016/j.resplu.2021.100112 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Clinical Paper
Ong, Gene Yong-Kwang
Ang, Aloysius Jian Feng
S O Aurangzeb, Amirzeb
Fong, Elisabeth Sue Shuen
Tan, Jun Yuan
Chen, Zhao Jin
Chan, Yiong Huak
Tang, Phua Hwee
Pek, Jen Heng
Maconochie, Ian
Ng, Kee Chong
Nadkarni, Vinay
What is the potential for over-compression using current paediatric chest compression guidelines? — A chest computed tomography study
title What is the potential for over-compression using current paediatric chest compression guidelines? — A chest computed tomography study
title_full What is the potential for over-compression using current paediatric chest compression guidelines? — A chest computed tomography study
title_fullStr What is the potential for over-compression using current paediatric chest compression guidelines? — A chest computed tomography study
title_full_unstemmed What is the potential for over-compression using current paediatric chest compression guidelines? — A chest computed tomography study
title_short What is the potential for over-compression using current paediatric chest compression guidelines? — A chest computed tomography study
title_sort what is the potential for over-compression using current paediatric chest compression guidelines? — a chest computed tomography study
topic Clinical Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8244421/
https://www.ncbi.nlm.nih.gov/pubmed/34223372
http://dx.doi.org/10.1016/j.resplu.2021.100112
work_keys_str_mv AT onggeneyongkwang whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT angaloysiusjianfeng whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT soaurangzebamirzeb whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT fongelisabethsueshuen whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT tanjunyuan whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT chenzhaojin whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT chanyionghuak whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT tangphuahwee whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT pekjenheng whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT maconochieian whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT ngkeechong whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy
AT nadkarnivinay whatisthepotentialforovercompressionusingcurrentpaediatricchestcompressionguidelinesachestcomputedtomographystudy