Cargando…

The retreatment abilities of ProTaper Next and F6 Skytaper: a micro-computed tomography study

PURPOSE: The aim of this study was to evaluate the retreatment abilities of the ProTaper Next (PTN) and F6 SkyTaper (F6) systems by using micro-computed tomography (microct), radiographic and microscopic imaging techniques. MATERIALS AND METHODS: The root canals of twenty-six extracted mandibular pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Saricam, Esma, Ince-Yusufoglu, Selen, Ocak, Mert, Geneci, Ferhat, Celik, H. Hamdi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Istanbul University Faculty of Dentistry 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8244941/
https://www.ncbi.nlm.nih.gov/pubmed/34250473
http://dx.doi.org/10.26650/eor.20210009
_version_ 1783716027604926464
author Saricam, Esma
Ince-Yusufoglu, Selen
Ocak, Mert
Geneci, Ferhat
Celik, H. Hamdi
author_facet Saricam, Esma
Ince-Yusufoglu, Selen
Ocak, Mert
Geneci, Ferhat
Celik, H. Hamdi
author_sort Saricam, Esma
collection PubMed
description PURPOSE: The aim of this study was to evaluate the retreatment abilities of the ProTaper Next (PTN) and F6 SkyTaper (F6) systems by using micro-computed tomography (microct), radiographic and microscopic imaging techniques. MATERIALS AND METHODS: The root canals of twenty-six extracted mandibular premolar teeth were prepared and obturated. For the retreatment procedure, the teeth were randomly divided into two equal groups according to endodontic instruments: PTN (X4) and F6 (#40/.06). Pre- and post-operative filling material volumes were measured with micro-ct, and areas were measured with radiographic and microscopic imaging techniques. The percentages of residual material were calculated, and then statistically compared. The significance level was set at p<0.05. RESULTS: There was no statistically significant difference between F6 and PTN for retreatment efficacy in the micro-ct and radiographic imaging techniques (p>0.05). PTN demonstrated better cleaning ability when evaluated by microscopic imaging. (p<0.05). The correlation was moderate between micro-ct and radiographic, and micro-ct and microscopic imaging groups; however, it was strong between radiographic and microscopic imaging methods. CONCLUSION: The PTN and F6 files had similar effects in the removal of filling material with microct evaluation. The radiographic imaging method gave similar results with micro-ct imaging.
format Online
Article
Text
id pubmed-8244941
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Istanbul University Faculty of Dentistry
record_format MEDLINE/PubMed
spelling pubmed-82449412021-07-09 The retreatment abilities of ProTaper Next and F6 Skytaper: a micro-computed tomography study Saricam, Esma Ince-Yusufoglu, Selen Ocak, Mert Geneci, Ferhat Celik, H. Hamdi Eur Oral Res Articles PURPOSE: The aim of this study was to evaluate the retreatment abilities of the ProTaper Next (PTN) and F6 SkyTaper (F6) systems by using micro-computed tomography (microct), radiographic and microscopic imaging techniques. MATERIALS AND METHODS: The root canals of twenty-six extracted mandibular premolar teeth were prepared and obturated. For the retreatment procedure, the teeth were randomly divided into two equal groups according to endodontic instruments: PTN (X4) and F6 (#40/.06). Pre- and post-operative filling material volumes were measured with micro-ct, and areas were measured with radiographic and microscopic imaging techniques. The percentages of residual material were calculated, and then statistically compared. The significance level was set at p<0.05. RESULTS: There was no statistically significant difference between F6 and PTN for retreatment efficacy in the micro-ct and radiographic imaging techniques (p>0.05). PTN demonstrated better cleaning ability when evaluated by microscopic imaging. (p<0.05). The correlation was moderate between micro-ct and radiographic, and micro-ct and microscopic imaging groups; however, it was strong between radiographic and microscopic imaging methods. CONCLUSION: The PTN and F6 files had similar effects in the removal of filling material with microct evaluation. The radiographic imaging method gave similar results with micro-ct imaging. Istanbul University Faculty of Dentistry 2021-05-04 2021-05-04 /pmc/articles/PMC8244941/ /pubmed/34250473 http://dx.doi.org/10.26650/eor.20210009 Text en Copyright © 2021 European Oral Research https://creativecommons.org/licenses/by-nc-nd/4.0/This article is licensed under Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) license ( (https://creativecommons.org/licenses/by-nc-nd/4.0/) ). Users must give appropriate credit, provide a link to the license, and indicate if changes were made. Users may do so in any reasonable manner, but not in any way that suggests the journal endorses its use. The material cannot be used for commercial purposes. If the user remixes, transforms, or builds upon the material, he/she may not distribute the modified material. No warranties are given. The license may not give the user all of the permissions necessary for his/her intended use. For example, other rights such as publicity, privacy, or moral rights may limit how the material can be used.
spellingShingle Articles
Saricam, Esma
Ince-Yusufoglu, Selen
Ocak, Mert
Geneci, Ferhat
Celik, H. Hamdi
The retreatment abilities of ProTaper Next and F6 Skytaper: a micro-computed tomography study
title The retreatment abilities of ProTaper Next and F6 Skytaper: a micro-computed tomography study
title_full The retreatment abilities of ProTaper Next and F6 Skytaper: a micro-computed tomography study
title_fullStr The retreatment abilities of ProTaper Next and F6 Skytaper: a micro-computed tomography study
title_full_unstemmed The retreatment abilities of ProTaper Next and F6 Skytaper: a micro-computed tomography study
title_short The retreatment abilities of ProTaper Next and F6 Skytaper: a micro-computed tomography study
title_sort retreatment abilities of protaper next and f6 skytaper: a micro-computed tomography study
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8244941/
https://www.ncbi.nlm.nih.gov/pubmed/34250473
http://dx.doi.org/10.26650/eor.20210009
work_keys_str_mv AT saricamesma theretreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy
AT inceyusufogluselen theretreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy
AT ocakmert theretreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy
AT geneciferhat theretreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy
AT celikhhamdi theretreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy
AT saricamesma retreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy
AT inceyusufogluselen retreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy
AT ocakmert retreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy
AT geneciferhat retreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy
AT celikhhamdi retreatmentabilitiesofprotapernextandf6skytaperamicrocomputedtomographystudy