Cargando…

In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats

BACKGROUND: Scavenging energy from biomechanical motions in vivo by energy converting devices, i.e., implantable harvesters, to obtain sustainable electrical energy is the ideal way to power implantable medical devices which require long term and continuous power supply. A novel self-powered cardiac...

Descripción completa

Detalles Bibliográficos
Autores principales: Xie, Feng, Qian, Xiaoqing, Li, Ning, Cui, Daxiang, Zhang, Hao, Xu, Zhiyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8246189/
https://www.ncbi.nlm.nih.gov/pubmed/34268413
http://dx.doi.org/10.21037/atm-21-1707
_version_ 1783716261852610560
author Xie, Feng
Qian, Xiaoqing
Li, Ning
Cui, Daxiang
Zhang, Hao
Xu, Zhiyun
author_facet Xie, Feng
Qian, Xiaoqing
Li, Ning
Cui, Daxiang
Zhang, Hao
Xu, Zhiyun
author_sort Xie, Feng
collection PubMed
description BACKGROUND: Scavenging energy from biomechanical motions in vivo by energy converting devices, i.e., implantable harvesters, to obtain sustainable electrical energy is the ideal way to power implantable medical devices which require long term and continuous power supply. A novel self-powered cardiac pacemaker is designed to achieve self-powered pacing. The kinetic energy of the heart was collected by an implanted piezoelectric energy collector and supplied to the cardiac pacemaker, and then the cardiac tissue was stimulated by the pacing electrode pierced from the outside of the heart to realize effective pacing effect and self-powered pacing. In this study, we evaluated the stability and biocompatibility of our previously described flexible buckling piezoelectric vibration energy harvester in vitro and in vivo. The biocompatibility, in vivo stability, and safety of the self-powered pacemaker with a flexible flexion piezoelectric vibratory energy harvesting device prepared were analyzed by performing cell and in vivo animal experiments. METHODS: The MTT(3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was used to detect the cell proliferation of H9C2 cells and HUVECs at 24, 48, and 72 hours. Computed tomography (CT) and cardiac ultrasound were used to evaluate the position and heart rate of pacemakers 12 weeks after implantation, and the changes of plasma biochemical indexes were detected by a biochemical detector. RESULTS: At 12 weeks after implantation, CT results showed that there were no changes in the position of the self-powered pacemaker. The device implanted into the thoracic cavity of rats demonstrated certain effects on cardiac function, while it did not have a significant effect on their blood biochemical indexes. CONCLUSIONS: the flexible buckling piezoelectric vibratory energy collector did not produce adverse effects on the myocardial tissue or on the normal proliferation of myocardial cells.
format Online
Article
Text
id pubmed-8246189
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-82461892021-07-14 In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats Xie, Feng Qian, Xiaoqing Li, Ning Cui, Daxiang Zhang, Hao Xu, Zhiyun Ann Transl Med Original Article BACKGROUND: Scavenging energy from biomechanical motions in vivo by energy converting devices, i.e., implantable harvesters, to obtain sustainable electrical energy is the ideal way to power implantable medical devices which require long term and continuous power supply. A novel self-powered cardiac pacemaker is designed to achieve self-powered pacing. The kinetic energy of the heart was collected by an implanted piezoelectric energy collector and supplied to the cardiac pacemaker, and then the cardiac tissue was stimulated by the pacing electrode pierced from the outside of the heart to realize effective pacing effect and self-powered pacing. In this study, we evaluated the stability and biocompatibility of our previously described flexible buckling piezoelectric vibration energy harvester in vitro and in vivo. The biocompatibility, in vivo stability, and safety of the self-powered pacemaker with a flexible flexion piezoelectric vibratory energy harvesting device prepared were analyzed by performing cell and in vivo animal experiments. METHODS: The MTT(3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was used to detect the cell proliferation of H9C2 cells and HUVECs at 24, 48, and 72 hours. Computed tomography (CT) and cardiac ultrasound were used to evaluate the position and heart rate of pacemakers 12 weeks after implantation, and the changes of plasma biochemical indexes were detected by a biochemical detector. RESULTS: At 12 weeks after implantation, CT results showed that there were no changes in the position of the self-powered pacemaker. The device implanted into the thoracic cavity of rats demonstrated certain effects on cardiac function, while it did not have a significant effect on their blood biochemical indexes. CONCLUSIONS: the flexible buckling piezoelectric vibratory energy collector did not produce adverse effects on the myocardial tissue or on the normal proliferation of myocardial cells. AME Publishing Company 2021-05 /pmc/articles/PMC8246189/ /pubmed/34268413 http://dx.doi.org/10.21037/atm-21-1707 Text en 2021 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Xie, Feng
Qian, Xiaoqing
Li, Ning
Cui, Daxiang
Zhang, Hao
Xu, Zhiyun
In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats
title In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats
title_full In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats
title_fullStr In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats
title_full_unstemmed In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats
title_short In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats
title_sort in vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8246189/
https://www.ncbi.nlm.nih.gov/pubmed/34268413
http://dx.doi.org/10.21037/atm-21-1707
work_keys_str_mv AT xiefeng invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats
AT qianxiaoqing invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats
AT lining invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats
AT cuidaxiang invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats
AT zhanghao invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats
AT xuzhiyun invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats