Cargando…
In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats
BACKGROUND: Scavenging energy from biomechanical motions in vivo by energy converting devices, i.e., implantable harvesters, to obtain sustainable electrical energy is the ideal way to power implantable medical devices which require long term and continuous power supply. A novel self-powered cardiac...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8246189/ https://www.ncbi.nlm.nih.gov/pubmed/34268413 http://dx.doi.org/10.21037/atm-21-1707 |
_version_ | 1783716261852610560 |
---|---|
author | Xie, Feng Qian, Xiaoqing Li, Ning Cui, Daxiang Zhang, Hao Xu, Zhiyun |
author_facet | Xie, Feng Qian, Xiaoqing Li, Ning Cui, Daxiang Zhang, Hao Xu, Zhiyun |
author_sort | Xie, Feng |
collection | PubMed |
description | BACKGROUND: Scavenging energy from biomechanical motions in vivo by energy converting devices, i.e., implantable harvesters, to obtain sustainable electrical energy is the ideal way to power implantable medical devices which require long term and continuous power supply. A novel self-powered cardiac pacemaker is designed to achieve self-powered pacing. The kinetic energy of the heart was collected by an implanted piezoelectric energy collector and supplied to the cardiac pacemaker, and then the cardiac tissue was stimulated by the pacing electrode pierced from the outside of the heart to realize effective pacing effect and self-powered pacing. In this study, we evaluated the stability and biocompatibility of our previously described flexible buckling piezoelectric vibration energy harvester in vitro and in vivo. The biocompatibility, in vivo stability, and safety of the self-powered pacemaker with a flexible flexion piezoelectric vibratory energy harvesting device prepared were analyzed by performing cell and in vivo animal experiments. METHODS: The MTT(3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was used to detect the cell proliferation of H9C2 cells and HUVECs at 24, 48, and 72 hours. Computed tomography (CT) and cardiac ultrasound were used to evaluate the position and heart rate of pacemakers 12 weeks after implantation, and the changes of plasma biochemical indexes were detected by a biochemical detector. RESULTS: At 12 weeks after implantation, CT results showed that there were no changes in the position of the self-powered pacemaker. The device implanted into the thoracic cavity of rats demonstrated certain effects on cardiac function, while it did not have a significant effect on their blood biochemical indexes. CONCLUSIONS: the flexible buckling piezoelectric vibratory energy collector did not produce adverse effects on the myocardial tissue or on the normal proliferation of myocardial cells. |
format | Online Article Text |
id | pubmed-8246189 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-82461892021-07-14 In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats Xie, Feng Qian, Xiaoqing Li, Ning Cui, Daxiang Zhang, Hao Xu, Zhiyun Ann Transl Med Original Article BACKGROUND: Scavenging energy from biomechanical motions in vivo by energy converting devices, i.e., implantable harvesters, to obtain sustainable electrical energy is the ideal way to power implantable medical devices which require long term and continuous power supply. A novel self-powered cardiac pacemaker is designed to achieve self-powered pacing. The kinetic energy of the heart was collected by an implanted piezoelectric energy collector and supplied to the cardiac pacemaker, and then the cardiac tissue was stimulated by the pacing electrode pierced from the outside of the heart to realize effective pacing effect and self-powered pacing. In this study, we evaluated the stability and biocompatibility of our previously described flexible buckling piezoelectric vibration energy harvester in vitro and in vivo. The biocompatibility, in vivo stability, and safety of the self-powered pacemaker with a flexible flexion piezoelectric vibratory energy harvesting device prepared were analyzed by performing cell and in vivo animal experiments. METHODS: The MTT(3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was used to detect the cell proliferation of H9C2 cells and HUVECs at 24, 48, and 72 hours. Computed tomography (CT) and cardiac ultrasound were used to evaluate the position and heart rate of pacemakers 12 weeks after implantation, and the changes of plasma biochemical indexes were detected by a biochemical detector. RESULTS: At 12 weeks after implantation, CT results showed that there were no changes in the position of the self-powered pacemaker. The device implanted into the thoracic cavity of rats demonstrated certain effects on cardiac function, while it did not have a significant effect on their blood biochemical indexes. CONCLUSIONS: the flexible buckling piezoelectric vibratory energy collector did not produce adverse effects on the myocardial tissue or on the normal proliferation of myocardial cells. AME Publishing Company 2021-05 /pmc/articles/PMC8246189/ /pubmed/34268413 http://dx.doi.org/10.21037/atm-21-1707 Text en 2021 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Xie, Feng Qian, Xiaoqing Li, Ning Cui, Daxiang Zhang, Hao Xu, Zhiyun In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats |
title | In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats |
title_full | In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats |
title_fullStr | In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats |
title_full_unstemmed | In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats |
title_short | In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats |
title_sort | in vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8246189/ https://www.ncbi.nlm.nih.gov/pubmed/34268413 http://dx.doi.org/10.21037/atm-21-1707 |
work_keys_str_mv | AT xiefeng invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats AT qianxiaoqing invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats AT lining invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats AT cuidaxiang invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats AT zhanghao invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats AT xuzhiyun invitroandinvivostudiesonthebiocompatibilityofaselfpoweredpacemakerwithaflexiblebucklingpiezoelectricvibrationenergyharvesterforrats |