Low false‐positive rate of perfusion index as a screening tool for neonatal aortic coarctation
AIM: Adding perfusion index (PI) to pulse oximetry screening (POS) may increase neonatal detection of CoA (aortic coarctation). A cut‐off <0.7% has been suggested but is associated with a high rate of false positives. We aimed to evaluate the specificity of PI when using repeated instead of singl...
Autores principales: | Lannering, Katarina, Elfvin, Anders, Mellander, Mats |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8246534/ https://www.ncbi.nlm.nih.gov/pubmed/33170979 http://dx.doi.org/10.1111/apa.15661 |
Ejemplares similares
-
Low risk of necrotising enterocolitis in enterally fed neonates with critical heart disease: an observational study
por: Nordenström, Kajsa, et al.
Publicado: (2020) -
Infective endarteritis and false mycotic aneurysm complicating aortic coarctation
por: Jaleleddine, Ziadi, et al.
Publicado: (2012) -
Neonatal repair of persistent fifth aortic arch and aortic coarctation
por: Divekar, Abhay A., et al.
Publicado: (2020) -
Intravascular Treatment of Left Subclavian Artery Aneurysm Coexisting with Aortic Coarctation in an Adult Patient
por: Pogorzelski, Ryszard, et al.
Publicado: (2017) -
Aortic Coarctation
por: Rossi, Umberto G., et al.
Publicado: (2020)