Cargando…

Dedicated plug based closure for large bore access –The MARVEL prospective registry

OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug‐based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore pe...

Descripción completa

Detalles Bibliográficos
Autores principales: Kroon, Herbert G., Tonino, Pim A.L., Savontaus, Mikko, Amoroso, Giovanni, Laine, Mika, Christiansen, Evald H., Toggweiler, Stefan, ten Berg, Jur, Sathananthan, Janarthanan, Daemen, Joost, de Jaegere, Peter P., Brueren, Guus B.R.G., Malmberg, Markus, Slagboom, Ton, Moriyama, Noriaki, Terkelsen, Christian J., Moccetti, Federico, Gheorghe, Livia, Webb, John, Wood, David, Van Mieghem, Nicolas M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8246962/
https://www.ncbi.nlm.nih.gov/pubmed/33347739
http://dx.doi.org/10.1002/ccd.29439
_version_ 1783716421932417024
author Kroon, Herbert G.
Tonino, Pim A.L.
Savontaus, Mikko
Amoroso, Giovanni
Laine, Mika
Christiansen, Evald H.
Toggweiler, Stefan
ten Berg, Jur
Sathananthan, Janarthanan
Daemen, Joost
de Jaegere, Peter P.
Brueren, Guus B.R.G.
Malmberg, Markus
Slagboom, Ton
Moriyama, Noriaki
Terkelsen, Christian J.
Moccetti, Federico
Gheorghe, Livia
Webb, John
Wood, David
Van Mieghem, Nicolas M.
author_facet Kroon, Herbert G.
Tonino, Pim A.L.
Savontaus, Mikko
Amoroso, Giovanni
Laine, Mika
Christiansen, Evald H.
Toggweiler, Stefan
ten Berg, Jur
Sathananthan, Janarthanan
Daemen, Joost
de Jaegere, Peter P.
Brueren, Guus B.R.G.
Malmberg, Markus
Slagboom, Ton
Moriyama, Noriaki
Terkelsen, Christian J.
Moccetti, Federico
Gheorghe, Livia
Webb, John
Wood, David
Van Mieghem, Nicolas M.
author_sort Kroon, Herbert G.
collection PubMed
description OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug‐based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC‐2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS‐score of 2.7 [IQR 2.0–4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20–120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real‐world conditions.
format Online
Article
Text
id pubmed-8246962
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-82469622021-07-02 Dedicated plug based closure for large bore access –The MARVEL prospective registry Kroon, Herbert G. Tonino, Pim A.L. Savontaus, Mikko Amoroso, Giovanni Laine, Mika Christiansen, Evald H. Toggweiler, Stefan ten Berg, Jur Sathananthan, Janarthanan Daemen, Joost de Jaegere, Peter P. Brueren, Guus B.R.G. Malmberg, Markus Slagboom, Ton Moriyama, Noriaki Terkelsen, Christian J. Moccetti, Federico Gheorghe, Livia Webb, John Wood, David Van Mieghem, Nicolas M. Catheter Cardiovasc Interv Valvular and Structural Heart Diseases OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug‐based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC‐2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS‐score of 2.7 [IQR 2.0–4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20–120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real‐world conditions. John Wiley & Sons, Inc. 2020-12-21 2021-05-01 /pmc/articles/PMC8246962/ /pubmed/33347739 http://dx.doi.org/10.1002/ccd.29439 Text en © 2020 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Valvular and Structural Heart Diseases
Kroon, Herbert G.
Tonino, Pim A.L.
Savontaus, Mikko
Amoroso, Giovanni
Laine, Mika
Christiansen, Evald H.
Toggweiler, Stefan
ten Berg, Jur
Sathananthan, Janarthanan
Daemen, Joost
de Jaegere, Peter P.
Brueren, Guus B.R.G.
Malmberg, Markus
Slagboom, Ton
Moriyama, Noriaki
Terkelsen, Christian J.
Moccetti, Federico
Gheorghe, Livia
Webb, John
Wood, David
Van Mieghem, Nicolas M.
Dedicated plug based closure for large bore access –The MARVEL prospective registry
title Dedicated plug based closure for large bore access –The MARVEL prospective registry
title_full Dedicated plug based closure for large bore access –The MARVEL prospective registry
title_fullStr Dedicated plug based closure for large bore access –The MARVEL prospective registry
title_full_unstemmed Dedicated plug based closure for large bore access –The MARVEL prospective registry
title_short Dedicated plug based closure for large bore access –The MARVEL prospective registry
title_sort dedicated plug based closure for large bore access –the marvel prospective registry
topic Valvular and Structural Heart Diseases
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8246962/
https://www.ncbi.nlm.nih.gov/pubmed/33347739
http://dx.doi.org/10.1002/ccd.29439
work_keys_str_mv AT kroonherbertg dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT toninopimal dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT savontausmikko dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT amorosogiovanni dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT lainemika dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT christiansenevaldh dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT toggweilerstefan dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT tenbergjur dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT sathananthanjanarthanan dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT daemenjoost dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT dejaegerepeterp dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT bruerenguusbrg dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT malmbergmarkus dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT slagboomton dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT moriyamanoriaki dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT terkelsenchristianj dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT moccettifederico dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT gheorghelivia dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT webbjohn dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT wooddavid dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry
AT vanmieghemnicolasm dedicatedplugbasedclosureforlargeboreaccessthemarvelprospectiveregistry