Cargando…

Barium Defecating Proctography and Dynamic Magnetic Resonance Proctography: Their Role and Patient’s Perception

OBJECTIVES: The objectives of the study were to compare the imaging findings and patient’s perception of barium defecating proctography and dynamic magnetic resonance (MR) proctography in patients with pelvic floor disorders. MATERIAL AND METHODS: This is a prospective study conducted on patients wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Korula, Deepa Rebecca, Chandramohan, Anuradha, John, Reetu, Eapen, Anu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Scientific Scholar 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8247951/
https://www.ncbi.nlm.nih.gov/pubmed/34221640
http://dx.doi.org/10.25259/JCIS_56_2021
_version_ 1783716620818972672
author Korula, Deepa Rebecca
Chandramohan, Anuradha
John, Reetu
Eapen, Anu
author_facet Korula, Deepa Rebecca
Chandramohan, Anuradha
John, Reetu
Eapen, Anu
author_sort Korula, Deepa Rebecca
collection PubMed
description OBJECTIVES: The objectives of the study were to compare the imaging findings and patient’s perception of barium defecating proctography and dynamic magnetic resonance (MR) proctography in patients with pelvic floor disorders. MATERIAL AND METHODS: This is a prospective study conducted on patients with pelvic floor disorders who consented to undergo both barium proctography and dynamic MR proctography. Imaging findings of both the procedures were compared. Inter-observer agreement (IOA) for key imaging features was assessed. Patient’s perception of these procedures was assessed using a short questionnaire and a visual analog scale. RESULTS: Forty patients (M: F =19:21) with a mean age of 43.65 years and range of 21–75 years were included for final analysis. Mean patient experience score was significantly better for MR imaging (MRI) (p < 0.001). However, patients perceived significantly higher difficulty in rectal evacuation during MRI studies (p = 0.003). While significantly higher number of rectoceles (p = 0.014) were diagnosed on MRI, a greater number of pelvic floor descent (p = 0.02) and intra-rectal intussusception (p = 0.011) were diagnosed on barium proctography. The IOA for barium proctography was substantial for identifying rectoceles, rectal prolapse and for determining M line, p < 0.001. There was excellent IOA for MRI interpretation of cystoceles, peritoneoceles, and uterine prolapse and substantial to excellent IOA for determining anal canal length and anorectal angle, p < 0.001. The mean study time for the barium and MRI study was 12 minutes and 15 minutes, respectively. CONCLUSION: Barium proctography was more sensitive than MRI for detecting pelvic floor descent and intrarectal intussusception. Although patients perceived better rectal emptying with barium proctography, the overall patient experience was better for dynamic MRI proctography.
format Online
Article
Text
id pubmed-8247951
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Scientific Scholar
record_format MEDLINE/PubMed
spelling pubmed-82479512021-07-02 Barium Defecating Proctography and Dynamic Magnetic Resonance Proctography: Their Role and Patient’s Perception Korula, Deepa Rebecca Chandramohan, Anuradha John, Reetu Eapen, Anu J Clin Imaging Sci Original Research OBJECTIVES: The objectives of the study were to compare the imaging findings and patient’s perception of barium defecating proctography and dynamic magnetic resonance (MR) proctography in patients with pelvic floor disorders. MATERIAL AND METHODS: This is a prospective study conducted on patients with pelvic floor disorders who consented to undergo both barium proctography and dynamic MR proctography. Imaging findings of both the procedures were compared. Inter-observer agreement (IOA) for key imaging features was assessed. Patient’s perception of these procedures was assessed using a short questionnaire and a visual analog scale. RESULTS: Forty patients (M: F =19:21) with a mean age of 43.65 years and range of 21–75 years were included for final analysis. Mean patient experience score was significantly better for MR imaging (MRI) (p < 0.001). However, patients perceived significantly higher difficulty in rectal evacuation during MRI studies (p = 0.003). While significantly higher number of rectoceles (p = 0.014) were diagnosed on MRI, a greater number of pelvic floor descent (p = 0.02) and intra-rectal intussusception (p = 0.011) were diagnosed on barium proctography. The IOA for barium proctography was substantial for identifying rectoceles, rectal prolapse and for determining M line, p < 0.001. There was excellent IOA for MRI interpretation of cystoceles, peritoneoceles, and uterine prolapse and substantial to excellent IOA for determining anal canal length and anorectal angle, p < 0.001. The mean study time for the barium and MRI study was 12 minutes and 15 minutes, respectively. CONCLUSION: Barium proctography was more sensitive than MRI for detecting pelvic floor descent and intrarectal intussusception. Although patients perceived better rectal emptying with barium proctography, the overall patient experience was better for dynamic MRI proctography. Scientific Scholar 2021-06-04 /pmc/articles/PMC8247951/ /pubmed/34221640 http://dx.doi.org/10.25259/JCIS_56_2021 Text en © 2021 Published by Scientific Scholar on behalf of Journal of Clinical Imaging Science https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Research
Korula, Deepa Rebecca
Chandramohan, Anuradha
John, Reetu
Eapen, Anu
Barium Defecating Proctography and Dynamic Magnetic Resonance Proctography: Their Role and Patient’s Perception
title Barium Defecating Proctography and Dynamic Magnetic Resonance Proctography: Their Role and Patient’s Perception
title_full Barium Defecating Proctography and Dynamic Magnetic Resonance Proctography: Their Role and Patient’s Perception
title_fullStr Barium Defecating Proctography and Dynamic Magnetic Resonance Proctography: Their Role and Patient’s Perception
title_full_unstemmed Barium Defecating Proctography and Dynamic Magnetic Resonance Proctography: Their Role and Patient’s Perception
title_short Barium Defecating Proctography and Dynamic Magnetic Resonance Proctography: Their Role and Patient’s Perception
title_sort barium defecating proctography and dynamic magnetic resonance proctography: their role and patient’s perception
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8247951/
https://www.ncbi.nlm.nih.gov/pubmed/34221640
http://dx.doi.org/10.25259/JCIS_56_2021
work_keys_str_mv AT koruladeeparebecca bariumdefecatingproctographyanddynamicmagneticresonanceproctographytheirroleandpatientsperception
AT chandramohananuradha bariumdefecatingproctographyanddynamicmagneticresonanceproctographytheirroleandpatientsperception
AT johnreetu bariumdefecatingproctographyanddynamicmagneticresonanceproctographytheirroleandpatientsperception
AT eapenanu bariumdefecatingproctographyanddynamicmagneticresonanceproctographytheirroleandpatientsperception