Cargando…

A comparative evaluation between the reliability of gypsum casts and digital greyscale intra‐oral scans for the scoring of tooth wear using the Tooth Wear Evaluation System (TWES)

BACKGROUND: The Tooth Wear Evaluation System (TWES) is a type of tooth wear index. To date, there is the lack of data comparing the reliability of the application of this index on gypsum cast records and digital greyscale intra‐oral scan records. OBJECTIVES: A comparative evaluation between the use...

Descripción completa

Detalles Bibliográficos
Autores principales: Mehta, Shamir B., Bronkhorst, Ewald M., Crins, Luuk, Huysmans, Marie‐Charlotte D. N. J, Wetselaar, Peter, Loomans, Bas A. C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8248338/
https://www.ncbi.nlm.nih.gov/pubmed/33370476
http://dx.doi.org/10.1111/joor.13141
_version_ 1783716701578199040
author Mehta, Shamir B.
Bronkhorst, Ewald M.
Crins, Luuk
Huysmans, Marie‐Charlotte D. N. J
Wetselaar, Peter
Loomans, Bas A. C.
author_facet Mehta, Shamir B.
Bronkhorst, Ewald M.
Crins, Luuk
Huysmans, Marie‐Charlotte D. N. J
Wetselaar, Peter
Loomans, Bas A. C.
author_sort Mehta, Shamir B.
collection PubMed
description BACKGROUND: The Tooth Wear Evaluation System (TWES) is a type of tooth wear index. To date, there is the lack of data comparing the reliability of the application of this index on gypsum cast records and digital greyscale intra‐oral scan records. OBJECTIVES: A comparative evaluation between the use of gypsum cast records and digital greyscale intra‐oral scan records with the reliability of tooth wear scoring using the TWES amongst a group of patients with tooth wear. METHODS: Records for 10 patients with moderate to severe tooth wear (TWES ≥ 2) were randomly selected from a larger clinical trial. TWES grading of the occlusal/incisal, buccal and palatal/lingual surfaces was performed to determine the levels of intra‐ and interobserver agreement. Intra‐observer reproducibility was based on the findings of one examiner only. For the interobserver reproducibility, the findings of two examiners were considered. One set of models/ records were used per patient. Cohen's weighted kappa (κ(W)) was used to ascertain agreement between and within the observers. Comparison of agreement was performed using t tests (P < .05). RESULTS: For the scoring of the of the total occlusal/incisal surfaces, the overall levels of intra‐ and interobserver agreement were significantly higher using the gypsum cast records than with the digital greyscale intra‐oral scan records, (P < .001) and (P < .001), respectively. For the overall buccal surfaces, only a significant difference was found in the intra‐observer agreement using gypsum casts, (P = .013). For the palatal/lingual surfaces, a significant difference was only reported in the interobserver agreement using gypsum casts, (P = .043). At the occlusal/incisal surfaces, grading performed using gypsum casts, culminated in significantly higher TWES scores than with the use of the digital greyscale intra‐oral scans (P < .001). At the buccal and palatal/lingual surfaces, significantly higher wear scores were obtained using digital greyscale intra‐oral scan records (P < .009). CONCLUSIONS: The TWES can offer a reliable means for the scoring of wearing occlusal/incisal surfaces using gypsum casts. The reliability offered by digital greyscale intra‐oral scans for consecutive scoring was in general, inferior.
format Online
Article
Text
id pubmed-8248338
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-82483382021-07-06 A comparative evaluation between the reliability of gypsum casts and digital greyscale intra‐oral scans for the scoring of tooth wear using the Tooth Wear Evaluation System (TWES) Mehta, Shamir B. Bronkhorst, Ewald M. Crins, Luuk Huysmans, Marie‐Charlotte D. N. J Wetselaar, Peter Loomans, Bas A. C. J Oral Rehabil Original Articles BACKGROUND: The Tooth Wear Evaluation System (TWES) is a type of tooth wear index. To date, there is the lack of data comparing the reliability of the application of this index on gypsum cast records and digital greyscale intra‐oral scan records. OBJECTIVES: A comparative evaluation between the use of gypsum cast records and digital greyscale intra‐oral scan records with the reliability of tooth wear scoring using the TWES amongst a group of patients with tooth wear. METHODS: Records for 10 patients with moderate to severe tooth wear (TWES ≥ 2) were randomly selected from a larger clinical trial. TWES grading of the occlusal/incisal, buccal and palatal/lingual surfaces was performed to determine the levels of intra‐ and interobserver agreement. Intra‐observer reproducibility was based on the findings of one examiner only. For the interobserver reproducibility, the findings of two examiners were considered. One set of models/ records were used per patient. Cohen's weighted kappa (κ(W)) was used to ascertain agreement between and within the observers. Comparison of agreement was performed using t tests (P < .05). RESULTS: For the scoring of the of the total occlusal/incisal surfaces, the overall levels of intra‐ and interobserver agreement were significantly higher using the gypsum cast records than with the digital greyscale intra‐oral scan records, (P < .001) and (P < .001), respectively. For the overall buccal surfaces, only a significant difference was found in the intra‐observer agreement using gypsum casts, (P = .013). For the palatal/lingual surfaces, a significant difference was only reported in the interobserver agreement using gypsum casts, (P = .043). At the occlusal/incisal surfaces, grading performed using gypsum casts, culminated in significantly higher TWES scores than with the use of the digital greyscale intra‐oral scans (P < .001). At the buccal and palatal/lingual surfaces, significantly higher wear scores were obtained using digital greyscale intra‐oral scan records (P < .009). CONCLUSIONS: The TWES can offer a reliable means for the scoring of wearing occlusal/incisal surfaces using gypsum casts. The reliability offered by digital greyscale intra‐oral scans for consecutive scoring was in general, inferior. John Wiley and Sons Inc. 2021-01-11 2021-06 /pmc/articles/PMC8248338/ /pubmed/33370476 http://dx.doi.org/10.1111/joor.13141 Text en © 2021 The Authors. Journal of Oral Rehabilitation published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
Mehta, Shamir B.
Bronkhorst, Ewald M.
Crins, Luuk
Huysmans, Marie‐Charlotte D. N. J
Wetselaar, Peter
Loomans, Bas A. C.
A comparative evaluation between the reliability of gypsum casts and digital greyscale intra‐oral scans for the scoring of tooth wear using the Tooth Wear Evaluation System (TWES)
title A comparative evaluation between the reliability of gypsum casts and digital greyscale intra‐oral scans for the scoring of tooth wear using the Tooth Wear Evaluation System (TWES)
title_full A comparative evaluation between the reliability of gypsum casts and digital greyscale intra‐oral scans for the scoring of tooth wear using the Tooth Wear Evaluation System (TWES)
title_fullStr A comparative evaluation between the reliability of gypsum casts and digital greyscale intra‐oral scans for the scoring of tooth wear using the Tooth Wear Evaluation System (TWES)
title_full_unstemmed A comparative evaluation between the reliability of gypsum casts and digital greyscale intra‐oral scans for the scoring of tooth wear using the Tooth Wear Evaluation System (TWES)
title_short A comparative evaluation between the reliability of gypsum casts and digital greyscale intra‐oral scans for the scoring of tooth wear using the Tooth Wear Evaluation System (TWES)
title_sort comparative evaluation between the reliability of gypsum casts and digital greyscale intra‐oral scans for the scoring of tooth wear using the tooth wear evaluation system (twes)
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8248338/
https://www.ncbi.nlm.nih.gov/pubmed/33370476
http://dx.doi.org/10.1111/joor.13141
work_keys_str_mv AT mehtashamirb acomparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT bronkhorstewaldm acomparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT crinsluuk acomparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT huysmansmariecharlottednj acomparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT wetselaarpeter acomparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT loomansbasac acomparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT mehtashamirb comparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT bronkhorstewaldm comparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT crinsluuk comparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT huysmansmariecharlottednj comparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT wetselaarpeter comparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes
AT loomansbasac comparativeevaluationbetweenthereliabilityofgypsumcastsanddigitalgreyscaleintraoralscansforthescoringoftoothwearusingthetoothwearevaluationsystemtwes